X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21877

Well Details

Well ID: 34-035-21877
Loading map...
County: Cuyahoga
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2006-01-25
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.52378831
Longitude: -81.40960313

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2006-0 580.0 0.0
2007-0 22869.0 44.0
2008-0 22074.0 111.0
2009-0 47684.0 66.0
2010-0 33208.0 0.0
2011-0 55438.0 77.0
2012-0 34676.0 0.0
2013-0 17685.0 0.0
2014-0 9463.0 365.0 17.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1101621931 2006-06-06 fencing up, trees planted
1407940640 2014-08-13 I inspected this producing unit as part of routine inspection activity. The well was completed in 02/01/2006. The unit is producing and production reports are current. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger-lift system and aboveground storage tank (AST) battery in separate board-on-board enclosures. The wellhead and battery are located within the confines of a commercial nursery operation. Access to the well and battery are via existing, shared, gravel roads within the nursery. These roads are noted to be in good condition. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-out is bull-plugged. The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. The ID placards at the battery and wellhead are in good condition.
1784309791 2013-01-08 The wellhead consists of a mechanical plunger lift in an 8-foot board-on-board enclosure which is locked. Unit identification is present and legible. I did not observe any leaks, spills, or other signs of contamination. I could not locate the tank battery for the unit.
218226393 2011-12-28 On 12/28/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.

For data sources see[2]