X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-085-20914

Well Details

Well ID: 34-085-20914
Loading map...
County: Lake
Municipality:
Operator Name: GIBSON RONALD A & ASSOC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1988-01-30
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.76264284
Longitude: -81.16052836

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1988-0 5803.0 88.0
1990-0 18819.0 460.0
1992-0 5040.0 42.0
1993-0 2885.0 43.0
1994-0 3747.0 44.0
1995-0 3126.0 0.0
1996-0 2526.0 39.0
1997-0 330.0 0.0
1998-0 1977.0 0.0
1999-0 1911.0 28.0
2000-0 1910.0 23.0
2001-0 1978.0 20.0
2002-0 2128.0 20.0
2003-0 1657.0 23.0
2004-0 1429.0 0.0
2005-0 1133.0 24.0
2006-0 1152.0 0.0
2007-0 2300.0 5.0
2008-0 4106.0 41.0
2009-0 2414.0 14.0
2010-0 1850.0 22.0
2011-0 2503.0 0.0
2012-0 2259.0 43.0
2013-0 1961.0 42.0
2014-0 1830.0 365.0 28.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1091147198 2010-02-03 There were no violations at the time of inspection.
1604986296 2013-10-02 The producing unit consists of a pump jack unit at the wellhead and an aboveground storage tank (AST) battery. The battery is comprised of 2 100-barrel steel production tanks and a separator unit. The elements are enclosed in separate chain-link enclosures. There is adequate secondary containment and signage at the battery but the wellhead needs a placard. No other problems noted. The battery is shared with the #917 unit.
326819802 2014-11-10 I inspected this location has part of routine inspection activity. The well is producing and production records are current. The fittings and connections at the pump jack are free from signs of leakage or other problems. The chain-link enclosure is intact and locked. Fittings at the tank battery are free from signs of leakage or problems. The load-outs are bull-plugged and locked. Safety equipment is present. Secondary containment is intact. ID Signage is present. The lease road, shared with the nursery facility, is comprised of hard-packed dirt and is dry and stable currently. The battery is shared with the #2-917 unit.
342480311 2012-02-09 Well is a pump jack unit, unit is fenced. Tank battery is fenced. There are two 100 BBL production tanks and a mechical separtor in the battery. Dike is in good repair.
717738538 2013-03-01 The producing unit consists of the following elements: A production wellhead and tank battery. The production wellhead is comprised of a pumpjack unit, not enclosed. The tank battery is comprised of 2 210-barrel (BBL) tanks, mechanical separator, and associated piping and appurtenances, not enclosed. The tank battery system is shared with the #848 producing unit. The ID sign for this unit is in poor condition. I did not observe any leaks, releases, or problems. In contacted Ron Gibson as advised him about the need for a new sign.
PL14190 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 