34-053-20896

Well Details

Well ID: 34-053-20896
Loading map...
County: Gallia
Municipality:
Operator Name: WYANT EXPLORATION COMPANY
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1984-02-04
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 38.96600164
Longitude: -82.17177144

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1986-0 2599.0 59.0
1990-0 1660.0 19.0
1992-0 1311.0 0.0
1993-0 948.0 0.0
1994-0 866.0 29.0
1995-0 1152.0 0.0
1996-0 1092.0 0.0
1997-0 1005.0 11.0
1998-0 887.0 7.0
2000-0 825.0 10.0
2001-0 740.0 0.0
2002-0 671.0 17.0
2003-0 689.0 0.0
2004-0 801.0 0.0
2005-0 575.0 0.0
2006-0 676.0 21.0
2007-0 613.0 0.0
2008-0 622.0 0.0
2009-0 518.0 0.0
2010-0 537.0 0.0
2011-0 513.0 0.0
2012-0 482.0 0.0
2013-0 343.0 0.0
2014-0 320.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1192170170 2003-12-17 No violations.
1269i1371 2002-09-12 P. REST MEETS REQUIREMENTS.
1269i521 2001-11-14 An inspection of the well revealed NO ID at the well, need full ID at well.
-1464449728 2013-04-16 This is a pneumatic wellhead. There is a 7-1/4 inch t-fitting at the ground surface. Rising above this fitting is a 4-1/4 inch casing to another t-fitting. There are 2-1/4 inch pipes attached to the horizontal openings on the fitting. Above this fitting is 1-7/8 inch production tubing rising to a master valve and finally into another t-fitting. Above this t-fitting is the rabbit tube for this wellhead. Identification sign is on the electric box. It could be a little larger. Tank battery is off County Road 25. It consists of two 100-barrel tanks (one for brine and the other for oil), two tall liquid/gas separators, and one small knock out tank on the gas line before the gas gauge meter.
1549633783 2003-12-17 Corrected.
1646468458 2001-11-14 FOLLOW UP TO NOV # 1269i521 An inspection of the well revealed NO ID at the well, need full ID at well.
1840690395 2003-04-18 No violations at the time of inspection.
541390718 2001-11-14 FOLLOW UP TO NOV # 1269i521 An inspection of the well revealed NO ID at the well, need full ID at well.
-548329695 2007-06-26 This NOV was passed on 12-17-2003 by Linda Slater.