Well ID: 34-005-23767 | |
County: Ashland | |
Municipality: | |
Operator Name: BASS ENERGY CO INC | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 1985-02-16 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Producing | |
Violations: 0 | |
Latitude: 40.99154474 | |
Longitude: -82.36804282 |
PERIOD | GAS QUANTITY | GAS PRODUCTION DAYS | CONDENSATE QUANTITY | CONDENSATE PRODUCTION DAYS | OIL QUANTITY | OIL PRODUCTION DAYS |
---|---|---|---|---|---|---|
1993-0 | 0.0 | 536.0 | ||||
1995-0 | 0.0 | 200.0 | ||||
1996-0 | 0.0 | 362.0 | ||||
1997-0 | 0.0 | 248.0 | ||||
2000-0 | 502.0 | 213.0 | ||||
2001-0 | 310.0 | 191.0 | ||||
2002-0 | 297.0 | 307.0 | ||||
2003-0 | 359.0 | 108.0 | ||||
2004-0 | 90.0 | 178.0 | ||||
2005-0 | 1.0 | 185.0 | ||||
2006-0 | 0.0 | 0.0 | ||||
2007-0 | 0.0 | 0.0 | ||||
2008-0 | 0.0 | 0.0 | ||||
2009-0 | 0.0 | 0.0 | ||||
2010-0 | 771.0 | 204.0 | ||||
2011-0 | 534.0 | 332.0 | ||||
2012-0 | 520.0 | 109.0 | ||||
2013-0 | 227.0 | 108.0 | ||||
2014-0 | 27.0 | 365.0 | 202.0 | 365.0 |
For data sources see[1]
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
1041609352 | 2003-01-03 | Well is in production. Pump jack, tubing and rods in well. Tank Battery has no dike. | Compliance Notice | |||
1247149277 | 2009-07-09 | Well is idle and no production reported for three years. Weeds are grown 6' around pump jack and tank battery. Identification face down on ground. Valves are shut in. | ||||
-1269532417 | 2009-11-17 | Well remains idle except landowner is receiving gas. No production reported since 2005. Belts off pump jack motor and weeds grown around well and tank battery. Called Bill Hlavin to advise well future. Sun, 50 degrees. | ||||
-285333205 | 2010-02-11 | Well is back in production and equipped with pump jack. 2-100 barrel tanks and separator in battery. 12 snow, 25 degrees. | ||||
-672084525 | 2015-04-03 | The well is equipped with a pump jack, rods, and tubing. The well is in production. There are 2-150 Bbl tanks, a 50 Bbl tank and a separator in the tank battery. There is no dike around the tanks. There is some brine staining from a petcock on the 2 inch pickup line from the tank battery. The operator was advised to have the tender stop draining brine from the valve when picking up from the tanks. Annular disposal is not hooked up. The database is mapping the well at the wrong location (40.99125; -82.37436). | ||||
847448745 | 2006-01-27 | No annular disposal hookup at well. Equipped with pump jack, rods and tubing. 2-100 barrel, 1-50 barrel tanks and separator at battery. Landowner using gas from well head. 30 degrees, sun. |
For data sources see[2]