If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-61100 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.78065274,"lon":-82.12642473,"icon":""}]} |
County: Wayne | |
Municipality: | |
Operator Name: BISHOP WELL SERVICES CORP. | |
Well Pad ID: | |
Farm/Lease Name: | |
First Permit Date: | |
Last Permit Date: | |
Spud Date: 2006-06-05 | |
Unconventional: No | |
Configuration: Vertical | |
Well Status: Final Restoration | |
Violations: 0 | |
Latitude: 40.78065274 | |
Longitude: -82.12642473 |
INSPECTION ID | DATE | DESCRIPTION | COMMENT | VIOLATION ID | VIOLATION CODE | VIOLATION COMMENT |
---|---|---|---|---|---|---|
-1083550444 | 2006-07-05 | Check final restoration and found that it is not done and that it needs to be graded and seeded. | ||||
1149106003 | 2006-05-31 | Dave Hodges requested a water sample from John Cutlip's water well at 1500 Bell Rd, Wooster, Oh. 44691. Dave Bishop is rigging up on an abandoned gas well leaking gas near Goody's home and 50' from water well. History of area indicates diminution problems. Collected a water sample from Cutlip's 2 water wells and sent to Cambridge lab. Wells are hooked together to supply water to home. #1 well is 240' and # 2 well is 160'. No odor or filtering equipment attached to system. Advised Bishop to begin drilling out gas well. 75 degrees, sunny. | ||||
1149262698 | 2006-06-02 | Requested by Dave Bishop to inspect drill site and BOP before drilling. Decision was made to run 7 casing to 300' and cement before cleaning out well or bridge. Water well area with in 20' of old gas and oil well. Emergency drill out and plug. | ||||
1166448402 | 2006-11-07 | This restoration is as poor as will pass .Advise operator that this will not pass in the future . | ||||
130972398 | 2006-09-13 | Vegetation has not taken and may need to be re-seeded . | ||||
-1451553304 | 2006-03-15 | Had complaint of gas leak and oil at surface along with a kill area around drive near home.I did a check of the area and found and old well near drive.Tried to run gas detector after charge and found it must not be holding a charge . | ||||
1566647676 | 2006-11-02 | Final restoration is as poor as it can be and still pass .I will pass it but make a note to the Plugging contractor that this type of restoration for the future will not work . | ||||
1851674611 | 2006-05-25 | Check on site and found that there is no equipment on this emergency plug ? Contact Dave Bishop and found that he will wait until after the Holiday to move rig in .Next contact landowner and advise of date to plug . | ||||
211037300 | 2006-03-16 | Met landowner on site and ran metal detector over area to find possible orphan well.Also met Fire Chief assistant on site to review gas leak which is still on going. | ||||
-36731020 | 2006-08-30 | Check final restoration on this site and found that it has been done and that needs time for vegetation to be established . | ||||
385681806 | 2006-04-17 | Work in New Phila and Uniontown office on emergency plug file to Dave Hodges . | ||||
688291141 | 2006-08-15 | Check to see if restoration has been completed and found that it has not .Area needs graded and seeded . | ||||
-70380703 | 2006-05-02 | Check on well to see if it was leaking more or less .No change. | ||||
-733991770 | 2006-07-05 | Needs maybe two mor weeks before final can be passed. | ||||
-800109101 | 2006-06-07 | Called by Dave Bishop. Rig was drilling at 740' when a gas pocket unloaded the hole and overflowed steel pit on ground. Drill mud was removed on grass of Goody residence. No injuries or home damage. S&H Water Service arrived with 2 trucks and pumped steel pits. I notified John Cutlip that well blew out and is under control. Loaded well with drilling mud and ran drill pipe to next bridge. Cloudy,75 degrees. | ||||
-835355189 | 2006-03-30 | Sketch site for emergency plug site.Drop off right of entry forms for landowner . | ||||
902497304 | 2006-03-23 | Check I &O site for equipment because of Emergency plug permit.There is no equipment on site.Met and talked with landowner and review info about the plug . | ||||
917174584 | 2006-10-11 | Check final restoration and found that it did not pass .Not enough vegetation and only modest grading.Contact Dave Bishop and advise of restoration .He felt restoration was more of the landowners problem .I advised that I could not pass it with that may rocks and no vegetation . |
For data sources see[1]