X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-081-61075

Well Details

Well ID: 34-081-61075
Loading map...
County: Jefferson
Municipality:
Operator Name: FIRSTENERGY GENERATION LLC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date:
Unconventional: No
Configuration: Vertical
Well Status: Final Restoration
Violations: 0
Latitude: 40.50897918
Longitude: -80.68829458

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1052432486 2013-10-15 The 4.5 casing was attempted to be pulled several times but the telegraph was lost each time it was attempted. Free pipe was found around 800 feet but it could only be shot off around 510'. The casing was mudded in so it was pulled and 2 3/8 tubing run into the hole. The well was cemented to surface after the hole was heavily conditioned to remove the clay used to mud the casing in. Cement was brought to surface but it will likely need to be topped off do to the hole taking the cement plug.
1382317785 2013-10-16 We were setting the final top plug for this well. Cement was tagged at 757' after a 45 sack plug. We tried to rip the 4.5 casing several times but were forced to shoot it off at 510'. We ran a 145 sack cement plug and circulated it to surface. The well had to be topped off several times as the cement was falling. The cement top will be checked the following day.
1426719092 2015-03-18 On the date of inspection I am accompanied by SE Regional Manager Brent Bear to inspect the plugged and abandoned well for Final Restoration. The well passes Final Restoration per ORC 1509.072(B).
-18791898 2013-10-17 The cement top was found at 18'. We topped off the well with left over cement from setting a cement plug on the previous well.
2119656804 2013-10-04 New GPS coordinates were taken for this well to determine if the proper API# has been assigned to the well. The current well does not appear to be of the age stated on the well card. After mapping the well the well is offset but does appear to be the correct numbering. This well will be soon plugged.

For data sources see[1]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20.