34-139-20717

Well Details

Well ID: 34-139-20717
Loading map...
County: Richland
Municipality:
Operator Name: ROMAN WELL SERVICES INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 2000-06-13
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 40.59171041
Longitude: -82.46965278

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
2000-0 0.0 0.0
2001-0 0.0 90.0
2002-0 426.0 561.0
2003-0 170.0 358.0
2004-0 154.0 159.0
2005-0 0.0 0.0
2006-0 0.0 0.0
2007-0 0.0 50.0
2013-0 0.0 51.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1274369669 2010-05-20 inspect well. Well capable of production and in production. ID posted. Production reported. Resolve NOV of 9/30/2005. Tubing pressure 200 psi, long string pressure 100 psi, and casing pressure 150 psi.
1430703124 2012-07-16 Inspect well and location. ID posted and site is ok.
-1560634628 2015-03-30 The well is equipped with a pump jack, rods and tubing and is in production. The well head is covered in paraffin. ID posted. There are 5 200 Bbl tanks in the tank battery along with a separator.
1713806628 2005-09-30 Inspect Well for Tom Tugend, with Jeff Fry. ID posted. Well shut in no belts on pump jack. No production unit at tanks. Well is incapable of production. 5/20/2010 well in production.
1861836373 2003-10-22 Inspect Well. Identification posted. Well capable of production. Stuffing box leaking. Power shut off, due to stuffing box.
259879784 2005-04-12 Inspect well. ID posted. Well is incapable of production. Belts have been removed from motor. The production unit has been removed.
740289205 2003-02-04 Well Inspection. Well capable of production. All valves open. Gauges showing zero presser. No Identification. Identification is illegible and requires remarking.


4-16-03: Follow up. No Change in well status. An excavation about 40 feet from pump jack reveals the buried electrical lines have been severed and exposed.

iDIAN005422 2000-11-08

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.