34-155-23009

Well Details

Well ID: 34-155-23009
Loading map...
County: Trumbull
Municipality:
Operator Name: DUSTIN ENERGY INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1986-11-28
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.31078351
Longitude: -80.81238421

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1987-0 5530.0 126.0
1988-0 17857.0 216.0
1989-0 15697.0 134.0
1990-0 9804.0 72.0
1991-0 7530.0 65.0
1992-0 9624.0 43.0
1993-0 11540.0 109.0
1994-0 14053.0 335.0
1995-0 8855.0 0.0
1996-0 9973.0 0.0
1997-0 5872.0 64.0
1998-0 13789.0 56.0
1999-0 11379.0 57.0
2000-0 9842.0 42.0
2001-0 4697.0 0.0
2002-0 0.0 0.0
2003-0 0.0 0.0
2005-0 0.0 0.0
2006-0 0.0 0.0
2007-0 0.0 0.0
2008-0 0.0 0.0
2009-0 0.0 0.0
2010-0 0.0 0.0
2011-0 0.0 0.0
2012-0 0.0 0.0
2013-0 0.0 0.0
2014-0 0.0 0.0 0.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
1216i945 2002-10-07 Well remains shut in. Non compliance.
138365282 2012-11-14 I conducted an urban production well inspection as a compliant from landowner Jill Huffman. My investigation found the plunger lift unit shut in on both the flow line and domestic line sides. The 2 unions to the flow lines and the 1 union to the domestic line were disconnected. The tank battery was partially overgrown with weeds, there were no identification signs, and the hatches on the 100 barrel oil tank and 50 barrel brine tank were open. There were weeds surrounding the separator and brine tank. I took photos of the production equipment. I researched our database and found ODNR Inspectors Jerry Kohl and Patrick Jonnie wrote 6 inspection reports indicating the well needed plugged in 2005 and 2006. I called Bill Templeton at 330-240-5573 and told him I was issuing two compliance notice violations; one for no identification signs (Ohio Revised Code 1501:9-9-05(E)(1)) and for nonproduction since 2007 (Ohio Administrative Code 1509.062(A)(1)) . I gave him one month (12/14/2012) to get the proper identification posted and remove the overgrown weeds. Bill informed me that he was planning to take East Ohio Gas to court for removing the meter run at the tank battery. Also, Bill said he wants to swab the well once the weather either freezes or by next summer, install new flow lines from the well to the tank battery, and put the well back into production. I have given Dustin Energy Inc. to 1/31/2013 to begin work to produce the well or file for a plugging permit.
1520325207 2003-06-04 Case#02-019 . Rachel Stahlman . Inspection showed well has not been put into production at this time .
-1673648125 2003-08-21 Case# 02-019 , Rachel Stahlman . Inspection showed well has not been put into production .
1839601289 2005-02-01 Case# 02-019 , Rachel Stahlman . Well has been put into production . No violations , RESOLVED .
241349171 2013-11-04 I called Bill Templeton concerning plugging or producing the well. Bill requested an extension to the beginning of summer for 2014. During the extension, Bill stated he is working on getting a swab rig to see if the well can be placed into production.
741409380 2002-08-30 FOLLOW UP TO NOV # 906 Met on site with complainant. Well has not operated for over one and a half years. The last production statement filed is for 2000. Well is shut in. Domestic hook-up is shut in. Plug or produce the idle well.
-903668598 2003-01-30 Inspection showed well is still idle at this time . The company [ Andy ] advised me they attempted to move equipment on wellsite to service well when the landowner, also the complaintant advised them if they were not going to plug well they were not allowed to enter his property .--
90677641 2002-08-30 Met on site with complainant. Well has not operated for over one and a half years. The last production statement filed is for 2000. Well is shut in. Domestic hook-up is shut in. Plug or produce the idle well.
PL3409 Preliminary Restoration done information from Data Point

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 
  2. "Ohio Department of Natural Resources RBDMS". [2]. 2015-06-19. Retrieved 2015-06-20.