Well Details

Well ID: 34-035-21643
Loading map...
County: Cuyahoga
Municipality:
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1997-08-21
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.5056311
Longitude: -81.49302048

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1998-0 34876.0 108.0
1999-0 46204.0 182.0
2000-0 22664.0 46.0
2001-0 12553.0 0.0
2002-0 8969.0 29.0
2003-0 8335.0 35.0
2004-0 6549.0 37.0
2005-0 5052.0 32.0
2006-0 3819.0 0.0
2007-0 3113.0 0.0
2008-0 1776.0 0.0
2009-0 2368.0 55.0
2010-0 2310.0 0.0
2011-0 1913.0 0.0
2012-0 2404.0 0.0
2013-0 1688.0 0.0
2014-0 1393.0 365.0 0.0 365.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1181530038 2015-03-04 I inspected this well as part of routine inspection activity. The well and battery can be accessed from a private drive which is a newly constructed road adjacent to the former Acacia Country Club. The well and battery are located within the former Acacia Country Club grounds. The wellhead mechanical plunger lift is located in a small chain-link enclosure. Connections and fittings at the wellhead and the battery are secure and free from signs of leakage or problems. Load-outs are plugged and secure. Gates are locked. At the time of this inspection, the areas surrounding the well and battery are snow-covered. I did not observe any signs of impact relating to production activity.
1527988442 2012-10-23 My visit to the well today was to perform an Urban Preliminary Restoration Inspection. Inspected the well head area. Well head is encased in a chain link fenced area and is secured with locks. This is a rabbit well. Well head are is neat and clean and no leaks are indicated. The tank battery is enclosed in a chain link fenced area and is secured with locks. There is one 140 BBL storage tank, and one 50 BBL brine tank. There is a vertical separator unit and a metering run. There are pick up lines at the site and they are secured by locks and bull plugs. Preliminary Restoration Passed.
-278787134 2013-09-27 The producing wellhead is fitted with a mechanical plunger lift and is located in a locked chain-link fence. The associated tank battery is comprised of 1 100-barrel steel production tank, 1 25-barrel poly brine tank, and separator. The battery is located in a separate chain-link enclosure. Load-outs are bull-plugged and locked. Secondary containment is good. The battery needs safety equipment (LPR valve, spark arrestor, carbon filter). I will discuss the missing items with Ralph Gregory of Bass Energy.
374811047 2014-10-09 I inspected this producing unit as part of routine inspection activity. The wellhead is comprised of a mechanical plunger lift system in a chain-link enclosure. Valves and connections are free from signs of leakage and appear functional. Areas surrounding the well area well maintained and free from signs of impact. The well is producing and production reports are current. Signage is present. The tank battery in a separate chain-link enclosure. The fittings and connections within the tank battery are free from leaks. The secondary containment is intact and the interior is free of signs of leaks, spills, or other problems. The load-outs are bull-plugged. The gate is secure.
-453954737 2004-08-09

For data sources see[2]