X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-20716

Well Details

Well ID: 34-155-20716
Loading map...
County: Trumbull
Municipality:
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name:
First Permit Date:
Last Permit Date:
Spud Date: 1977-11-10
Unconventional: No
Configuration: Vertical
Well Status: Producing
Violations: 0
Latitude: 41.33712406
Longitude: -80.92152855

Production Data

PERIOD GAS QUANTITY GAS PRODUCTION DAYS CONDENSATE QUANTITY CONDENSATE PRODUCTION DAYS OIL QUANTITY OIL PRODUCTION DAYS
1984-0 6297.0 64.0
1985-0 4466.0 113.0
1986-0 3118.0 37.0
1987-0 4327.0 73.0
1988-0 5229.0 61.0
1989-0 4487.0 76.0
1990-0 4303.0 45.0
1991-0 3452.0 58.0
1992-0 3694.0 0.0
1993-0 3889.0 115.0
1994-0 2987.0 58.0
1995-0 2051.0 0.0
1996-0 3266.0 68.0
1997-0 3540.0 63.0
1998-0 2456.0 55.0
1999-0 2150.0 41.0
2000-0 1357.0 0.0
2001-0 850.0 168.0
2002-0 872.0 36.0
2003-0 1041.0 31.0
2004-0 1981.0 0.0
2005-0 2524.0 0.0
2006-0 2872.0 103.0
2008-0 1586.0 81.0
2009-0 3346.0 0.0
2011-0 38.0 0.0
2012-0 1148.0 0.0

For data sources see[1]

Inspection Data

INSPECTION ID DATE DESCRIPTION COMMENT VIOLATION ID VIOLATION CODE VIOLATION COMMENT
-1136935408 2006-12-26 no violations . Compliance Notice
-1136935408 2006-12-26 no violations . Compliance Notice
1234691965 2012-07-10 On 7/10/2012, I conducted a production well inspection status check. My inspection found the well was a plunger lift unit (rabbit) that was in good condition. The tank battery contained one 100 barrel oil storage tank, with no well information on the identification sign, one 50 barrel brine storage tank and a separator. I noticed no visible spills or leaks. The lease road was in good condition, inspection not passed.
1393509014 2014-02-26 I was on location today to check compliance of Chief's Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator shows the well has been produced since the last chart change on 2-19-2014. The lease road is in stable condition. The well is in production which is in non-compliance of Chief's Order 2014-43. The well needs shut-in immediately.
-1645359797 2014-10-08 The company has received a stay from the chiefs order and is allowed to operate their wells. The compliance notice on the well can be removed.
1937176973 2014-02-28 My inspection today is a follow-up inspection to Compliance Notice # 1393509014, which was issued for non-compliance of Chief's Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator has been changed since my last inspection. The chart was replaced on 2-26-2014 and the new chart has shown production since it was put on. The lease road is in stable condition. The well is in production which is in non-compliance of Chief's Order 2014-43. The well needs shut-in immediately.
214855861 2014-01-14 My inspection found the proper identification sign posted with the correct information per my request.
-628708897 2014-03-10 I was on location to perform a follow-up inspection to compliance notice #1393509014, which was issued in reference to Chief's Order 2014-43. My inspection found a production chart inside the separator with no date. The flow line valves leading to and exiting the separator were open. A valve on the flow line at the well was open. The digital meter on the dump valve at the well was showing a digital number. The well was in production which was in non-compliance of Chief's Order 2014-43. The well needs to be shut-in immediately.

For data sources see[2]

References

  1. "Ohio Department of Natural Resources RBDMS". [1]. 2015-06-19. Retrieved 2015-06-20. 