Well Details

Well ID: 37-105-21651
Loading map...
Country: United States
State: Pennsylvania
County: Potter
Municipality: Wharton Township
Operator Name: PA GEN ENERGY CO LLC
Well Pad ID: 149058
Farm/Lease Name: PINE HILL PAD A 2413
License Status: Active
Spud Date: 05/05/2010
Permit Date: 3/15/2010
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.614799
Longitude: -77.876404

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 PA GEN ENERGY CO LLC 246,231.00 87 0.00 0 0.00 0
2011 PA GEN ENERGY CO LLC 503,693.00 365 0.00 0 0.00 0
2012 PA GEN ENERGY CO LLC 269,436.00 362 0.00 0 0.00 0
2013 PA GEN ENERGY CO LLC 237,787.00 362 0.00 0 0.00 0
2014 PA GEN ENERGY CO LLC 196,443.00 307 0.00 0 0.00 0
2015 PA GEN ENERGY CO LLC 181,632.00 365 0.00 0 0.00 0
2016 PA GEN ENERGY CO LLC 154,791.00 366 0.00 0 0.00 0
2017 PA GEN ENERGY CO LLC 129,981.00 363 0.00 0 0.00 0
2018 PA GEN ENERGY CO LLC 107,069.00 332 0.00 0 0.00 0
2019 PA GEN ENERGY CO LLC 27,356.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-2 Drill Cuttings (in Tons) 548.38 Tons LANDFILL 100361
2010-2 Drilling Fluid Waste (in Barrels) 67.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-2 Drilling Fluid Waste (in Barrels) 518.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010-2 Fracing Fluid Waste (in Barrels) 464.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-2 Fracing Fluid Waste (in Barrels) 5,277.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010-2 Produced Fluid (in Barrels) 1,705.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2010-2 Produced Fluid (in Barrels) 2,253.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2010-3 Drill Cuttings (in Tons) 448.01 Tons LANDFILL 100361
2010-3 Drill Cuttings (in Tons) 258.22 Tons ON SITE ENCAPSULATION
2010-3 Drilling Fluid Waste (in Barrels) 33.33 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-1 Fracturing Fluid Waste (in Tons) 66.49 Tons LANDFILL NY # 02S17
2011-1 Produced Fluid (in Barrels) 5,638.87 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-1 Produced Fluid (in Barrels) 708.46 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0102784
2011-2 Produced Fluid (in Barrels) 104.32 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 34-099-23127
2011-2 Produced Fluid (in Barrels) 227.56 Bbl INJECTION DISPOSAL WELL 34-007-24355
2011-2 Produced Fluid (in Barrels) 117.75 Bbl INJECTION DISPOSAL WELL 34-133-21076
2011-2 Produced Fluid (in Barrels) 43.98 Bbl INJECTION DISPOSAL WELL 34-133-24096
2011-2 Produced Fluid (in Barrels) 6,068.19 Bbl INJECTION DISPOSAL WELL UIC 45
2012-1 Produced Fluid (in Barrels) 419.75 Bbl INJECTION DISPOSAL WELL 34-151-23420
2012-1 Produced Fluid (in Barrels) 730.50 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012-1 Produced Fluid (in Barrels) 1,647.75 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012-1 Produced Fluid (in Barrels) 755.69 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 4,959.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2012-2 Produced Fluid (in Barrels) 307.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2012-2 Produced Fluid (in Barrels) 307.00 Bbl INJECTION DISPOSAL WELL 34-155-21894
2012-2 Produced Fluid (in Barrels) 307.00 Bbl INJECTION DISPOSAL WELL 34-155-23203
2012-2 Produced Fluid (in Barrels) 1,097.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013-1 Produced Fluid (in Barrels) 26.24 Bbl INJECTION DISPOSAL WELL 34-133-22523
2013-1 Produced Fluid (in Barrels) 77.50 Bbl INJECTION DISPOSAL WELL 34-133-23614
2013-1 Produced Fluid (in Barrels) 252.50 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013-1 Produced Fluid (in Barrels) 252.50 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013-1 Produced Fluid (in Barrels) 252.50 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013-1 Produced Fluid (in Barrels) 995.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013-2 Produced Fluid (in Barrels) 26.24 Bbl INJECTION DISPOSAL WELL 34-133-23614
2013-2 Produced Fluid (in Barrels) 146.67 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013-2 Produced Fluid (in Barrels) 146.67 Bbl INJECTION DISPOSAL WELL 34-155-21894
2013-2 Produced Fluid (in Barrels) 233.74 Bbl INJECTION DISPOSAL WELL 34-155-22403
2013-2 Produced Fluid (in Barrels) 146.67 Bbl INJECTION DISPOSAL WELL 34-155-23203
2013-2 Produced Fluid (in Barrels) 758.50 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013-2 Produced Fluid (in Barrels) 27.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014-1 Produced Fluid (in Barrels) 145.83 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014-1 Produced Fluid (in Barrels) 145.83 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014-1 Produced Fluid (in Barrels) 76.25 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014-1 Produced Fluid (in Barrels) 145.83 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014-1 Produced Fluid (in Barrels) 367.62 Bbl INJECTION DISPOSAL WELL 34-155-23795
2014-2 Produced Fluid (in Barrels) 28.74 Bbl INJECTION DISPOSAL WELL 34-151-23420
2014-2 Produced Fluid (in Barrels) 250.02 Bbl INJECTION DISPOSAL WELL 34-155-21438
2014-2 Produced Fluid (in Barrels) 148.74 Bbl INJECTION DISPOSAL WELL 34-155-21447
2014-2 Produced Fluid (in Barrels) 118.90 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014-2 Produced Fluid (in Barrels) 118.93 Bbl INJECTION DISPOSAL WELL 34-155-21894
2014-2 Produced Fluid (in Barrels) 161.24 Bbl INJECTION DISPOSAL WELL 34-155-22403
2014-2 Produced Fluid (in Barrels) 118.90 Bbl INJECTION DISPOSAL WELL 34-155-23203
2014-2 Produced Fluid (in Barrels) 50.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2014-2 Produced Fluid (in Barrels) 99.50 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014-2 Produced Fluid (in Barrels) 336.02 Bbl INJECTION DISPOSAL WELL 34-155-23795
2015-1 Produced Fluid (in Barrels) 158.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015-1 Produced Fluid (in Barrels) 160.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015-1 Produced Fluid (in Barrels) 177.50 Bbl INJECTION DISPOSAL WELL 34-155-21447
2015-1 Produced Fluid (in Barrels) 157.50 Bbl INJECTION DISPOSAL WELL 34-155-23732
2015-1 Produced Fluid (in Barrels) 25.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2015-1 Produced Fluid (in Barrels) 75.00 Bbl INJECTION DISPOSAL WELL 34-155-24078
2015-1 Produced Fluid (in Barrels) 77.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-1 Produced Fluid (in Barrels) 443.25 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 50.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015-2 Produced Fluid (in Barrels) 636.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015-2 Produced Fluid (in Barrels) 26.25 Bbl INJECTION DISPOSAL WELL 34-007-21847
2015-2 Produced Fluid (in Barrels) 52.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 103.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-2 Produced Fluid (in Barrels) 310.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 177.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016-1 Produced Fluid (in Barrels) RWC 802 816.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016-1 Produced Fluid (in Barrels) RWC 802 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3097
2016-1 Produced Fluid (in Barrels) RWC 802 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3177
2016-1 Produced Fluid (in Barrels) RWC 802 10.50 Bbl INJECTION DISPOSAL WELL 34-007-2-3692
2016-1 Produced Fluid (in Barrels) RWC 802 52.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2016-1 Produced Fluid (in Barrels) RWC 802 10.50 Bbl INJECTION DISPOSAL WELL 34-007-23262
2016-1 Produced Fluid (in Barrels) RWC 802 10.50 Bbl INJECTION DISPOSAL WELL 34-007-24355
2016-2 Produced Fluid (in Barrels) RWC 802 103.75 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016-2 Produced Fluid (in Barrels) RWC 802 942.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017-01 Produced Fluid (in Barrels) RWC 802 165.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-02 Produced Fluid (in Barrels) RWC 802 173.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-03 Other Oil & Gas Wastes (in Barrels) RWC 899 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-03 Produced Fluid (in Barrels) RWC 802 160.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-04 Produced Fluid (in Barrels) RWC 802 81.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-05 Produced Fluid (in Barrels) RWC 802 26.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-05 Produced Fluid (in Barrels) RWC 802 136.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-06 Produced Fluid (in Barrels) RWC 802 82.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-06 Produced Fluid (in Barrels) RWC 802 83.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-07 Produced Fluid (in Barrels) RWC 802 157.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-08 Produced Fluid (in Barrels) RWC 802 3.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017-08 Produced Fluid (in Barrels) RWC 802 113.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-09 Produced Fluid (in Barrels) RWC 802 147.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-10 Produced Fluid (in Barrels) RWC 802 165.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-11 Produced Fluid (in Barrels) RWC 802 165.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017-12 Produced Fluid (in Barrels) RWC 802 167.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-01 Produced Fluid (in Barrels) RWC 802 25.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-01 Produced Fluid (in Barrels) RWC 802 55.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-01 Produced Fluid (in Barrels) RWC 802 77.50 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 82.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-02 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 163.75 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-04 Produced Fluid (in Barrels) RWC 802 27.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018-04 Produced Fluid (in Barrels) RWC 802 135.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-05 Produced Fluid (in Barrels) RWC 802 175.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-06 Produced Fluid (in Barrels) RWC 802 185.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-07 Produced Fluid (in Barrels) RWC 802 51.25 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-07 Produced Fluid (in Barrels) RWC 802 62.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-08 Produced Fluid (in Barrels) RWC 802 78.75 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-08 Produced Fluid (in Barrels) RWC 802 122.50 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 26.25 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-09 Produced Fluid (in Barrels) RWC 802 155.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-10 Produced Fluid (in Barrels) RWC 802 196.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-11 Produced Fluid (in Barrels) RWC 802 26.25 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018-11 Produced Fluid (in Barrels) RWC 802 207.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-11 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 32.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018-12 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 52.50 Bbl INJECTION DISPOSAL WELL 34-007-21847
2019-01 Produced Fluid (in Barrels) RWC 802 27.50 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 137.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019-02 Produced Fluid (in Barrels) RWC 802 81.25 Bbl REUSE (AT WELL PAD)
2019-03 Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 120.96 Tons LANDFILL 301358

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1882372 Primary Facility 05/06/2010 Routine/Partial Inspection Violation(s) Noted No site ID sign, accelerated erosion, pit and impoundment not above SHWT, impoundment has holes in liner, waste burried in soil stockpile, drilling mud on ground
1884249 Primary Facility 05/13/2010 Compliance Evaluation Violation(s) Noted Accelerated erosion, drilling mud on ground, drill pit not 20 inches above SHWT
1886368 Primary Facility 05/19/2010 Compliance Evaluation No Violations Noted
1891980 Primary Facility 06/16/2010 Drilling/Alteration No Violations Noted
1895650 Primary Facility 07/01/2010 Drilling/Alteration No Violations Noted
1928109 Primary Facility 11/12/2010 Routine/Partial Inspection No Violations Noted
2016924 Primary Facility 11/02/2011 Routine/Complete Inspection No Violations Noted An inspection was conducted at the Pine Hill Pad A site on 11/2/11. The E&S plan and site perimeter were observed. The wells is production and the site was stable. No violations were cited during this inspection. - MRN
2103014 Primary Facility 09/12/2012 Routine/Complete Inspection No Violations Noted
2146943 Primary Facility 03/11/2013 Site Restoration No Violations Noted An inspection of the Pine Hill Pad A in Wharton township, Potter County was conducted on March 11, 2013 in response to a Well Site Restoration Reports received by the Department (for wells 1941, 2143, 2414 and 2415) . The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed. The Restoration reports were deemed approved. No violations were cited during this inspection.
2364548 Primary Facility 04/20/2015 Routine/Complete Inspection No Violations Noted
2461451 Primary Facility 2016-03-04 Routine/Complete Inspection No Violations Noted Routine inspection. Four wells have been drilled. Site is restored. Pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations cited. TLT
2576295 Primary Facility 2017-03-28 Routine/Complete Inspection No Violations Noted
2687446 Primary Facility 2018-01-26 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly all fittings all flow lines and the cellar area were tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area.
2722132 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted Four wells have been drilled. The site is restored per the requirements of post-drilling restoration The impervious area of the pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations were noted during this inspection
2737862 Primary Facility 2018-06-05 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production.
2802442 Primary Facility 2018-11-09 Administrative/File Review No Violations Noted Admin inspection for purpose of linking to a plugging COA.
2823895 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. There was no gauge on the approximate 3" flow line. This well has the annular vents hard piped /plumbed to the waste/ production tanks that are in a steel walled containment. No violations were noted at this inspection.
2833832 Primary Facility 2019-01-30 Incident- Response to Accident or Event Violation(s) Noted The DEP conducted an incident inspection of PGE's Pine Hill 1941 Well Pad in Wharton Twp, Potter County on 1/30/2019 at 1215 hours. The inspection was conducted in response to a spill reported to the DEP Report hotline by Nathan Harris (PGE). It was reported that at approximately 0900 a vac truck that was moving produced water from a production tank had "collapsed". The tank was estimated to have had 25 barrels of liquid inside when it collapsed.

DEP WQS, Jonathan Pennings and I arrived onsite at 1215 hours. When we arrived the truck was still in place and crew was observed sucking up fluids from the pad surface. We observed the vac truck(see photo #1) and the impacted area (photo #2 & 14). Puddles and slush mixes were field measured with a PCSTestr returning readings ranging from ~2.0 ms/cm to ~15.0 ms/cm (see photos #3, 4 & 5).

We spoke with Erick Duzick (PGE Completions Engineer) onsite who explained the vac trucks relief valve was frozen solid which had caused the truck to create a vacuum which in ret

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1882372 586503 05/06/2010 05/19/2010 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1882372 586504 05/06/2010 05/19/2010 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1882372 586505 05/06/2010 05/19/2010 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative
1882372 586506 05/06/2010 05/19/2010 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety 35 PS 691.402
1882372 586507 05/06/2010 05/19/2010 51017 - Administrative Code-General Administrative 35 PS 6018.301
1884249 586957 05/13/2010 05/19/2010 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1884249 586958 05/13/2010 05/19/2010 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative
1884249 586959 05/13/2010 05/19/2010 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety 35 PS 691.402
1884249 586960 05/13/2010 05/19/2010 51017 - Administrative Code-General Administrative 35 PS 6018.301
2833832 840719 2019-01-30 CSL 402(b) Environmental Health & Safety The release of a regulated substance to the pad surface is in violation of CSL 402(b) for the potential to pollute the waters of the Commonwealth.
2833832 840720 2019-01-30 78a57(a) Environmental Health & Safety The release of the regulated substance to the pad surface is in violation of 25 Pa Code Section 78a57(a) for failure to collect fluids producing during operation of a well in a tank or other container approved by the Department.
2833832 840721 2019-01-30 SWMA 301 Environmental Health & Safety The release of the regulated substance to the pad surface is in violation of SWMA 301 regarding transport, storage or disposal of residual waste inconsistent with Department regulations.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
840719 371900 NOV - Notice of Violation
840720 371900 NOV - Notice of Violation
840721 371900 NOV - Notice of Violation

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 09/21/2010 09/21/2010 6200.0 6169894.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand Superior Well Services Proppant Crystalline Silica (quartz) 14808-60-7 100.0 12.7455
AI -2 Superior Well Services Acid Inhibitor Glycol Ether 111-76-2 30.0 0.00008000
WFR-3B Superior Well Services Friction Reducer Hydrotreated Light Distillate 64742-47-8 30.0 0.02228
Water* PGE Carrier/Base Fluid 7732-18-5 100.0 85.9211
Acid, Hydrochloric (3) Superior Well Services Solvent Hydrochloric Acid 7647-01-0 3.0 0.03712
Propargyl Alcohol 107-19-7 30.0 0.00008000
Isopropyl Alcohol 67-63-0 30.0 0.00008000
Ethoxylated Alcohols 68551-12-2 4.0 0.00297
Diethylene Glycol 111-46-6 3.5 0.00036
Propylene Glycol 57-55-6 25.0 0.01857
Anionic copolymer Proprietary 10.0 0.00112
Mineral Spirits 8052-41-3 10.0 0.00743
Anionic polymer Proprietary 10.0 0.00112
Polyethylene Glycol 25322-68-3 50.0 0.00519
2-Phosphonobutane-1,2,4 tricarboxylic acid 37971-36-1 10.0 0.00112
Proprietary Component Proprietary 7.0 0.00002000
Ethylene Glycol 107-21-1 1.0 0.01037
Super TSC Superior Well Services Scale Inhibitor Propylene glycol 57-55-6 50.0 0.0056
KR-153SL Superior Well Services Biocide 2,2-Dibromo-3-nitrilo-propionamide 10222-01-2 20.0 0.00207

For data sources see[7]