{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.614799,"lon":-77.876404,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Potter | |
Municipality: Wharton Township | |
Operator Name: PA GEN ENERGY CO LLC | |
Well Pad ID: 149058 | |
Farm/Lease Name: PINE HILL PAD A 2413 | |
License Status: Active | |
Spud Date: 05/05/2010 | |
Permit Date: 3/15/2010 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.614799 | |
Longitude: -77.876404 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | PA GEN ENERGY CO LLC | 246,231.00 | 87 | 0.00 | 0 | 0.00 | 0 |
2011 | PA GEN ENERGY CO LLC | 503,693.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | PA GEN ENERGY CO LLC | 269,436.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2013 | PA GEN ENERGY CO LLC | 237,787.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2014 | PA GEN ENERGY CO LLC | 196,443.00 | 307 | 0.00 | 0 | 0.00 | 0 |
2015 | PA GEN ENERGY CO LLC | 181,632.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | PA GEN ENERGY CO LLC | 154,791.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | PA GEN ENERGY CO LLC | 129,981.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2018 | PA GEN ENERGY CO LLC | 107,069.00 | 332 | 0.00 | 0 | 0.00 | 0 |
2019 | PA GEN ENERGY CO LLC | 27,356.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2010-2 | Drill Cuttings (in Tons) | 548.38 Tons | LANDFILL | 100361 |
2010-2 | Drilling Fluid Waste (in Barrels) | 67.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010-2 | Drilling Fluid Waste (in Barrels) | 518.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010-2 | Fracing Fluid Waste (in Barrels) | 464.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010-2 | Fracing Fluid Waste (in Barrels) | 5,277.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010-2 | Produced Fluid (in Barrels) | 1,705.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2010-2 | Produced Fluid (in Barrels) | 2,253.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2010-3 | Drill Cuttings (in Tons) | 448.01 Tons | LANDFILL | 100361 |
2010-3 | Drill Cuttings (in Tons) | 258.22 Tons | ON SITE ENCAPSULATION | |
2010-3 | Drilling Fluid Waste (in Barrels) | 33.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011-1 | Fracturing Fluid Waste (in Tons) | 66.49 Tons | LANDFILL | NY # 02S17 |
2011-1 | Produced Fluid (in Barrels) | 5,638.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0101508 |
2011-1 | Produced Fluid (in Barrels) | 708.46 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | PA0102784 |
2011-2 | Produced Fluid (in Barrels) | 104.32 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 34-099-23127 |
2011-2 | Produced Fluid (in Barrels) | 227.56 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2011-2 | Produced Fluid (in Barrels) | 117.75 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2011-2 | Produced Fluid (in Barrels) | 43.98 Bbl | INJECTION DISPOSAL WELL | 34-133-24096 |
2011-2 | Produced Fluid (in Barrels) | 6,068.19 Bbl | INJECTION DISPOSAL WELL | UIC 45 |
2012-1 | Produced Fluid (in Barrels) | 419.75 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2012-1 | Produced Fluid (in Barrels) | 730.50 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012-1 | Produced Fluid (in Barrels) | 1,647.75 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012-1 | Produced Fluid (in Barrels) | 755.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Produced Fluid (in Barrels) | 4,959.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2012-2 | Produced Fluid (in Barrels) | 307.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012-2 | Produced Fluid (in Barrels) | 307.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2012-2 | Produced Fluid (in Barrels) | 307.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2012-2 | Produced Fluid (in Barrels) | 1,097.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013-1 | Produced Fluid (in Barrels) | 26.24 Bbl | INJECTION DISPOSAL WELL | 34-133-22523 |
2013-1 | Produced Fluid (in Barrels) | 77.50 Bbl | INJECTION DISPOSAL WELL | 34-133-23614 |
2013-1 | Produced Fluid (in Barrels) | 252.50 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013-1 | Produced Fluid (in Barrels) | 252.50 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2013-1 | Produced Fluid (in Barrels) | 252.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2013-1 | Produced Fluid (in Barrels) | 995.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013-2 | Produced Fluid (in Barrels) | 26.24 Bbl | INJECTION DISPOSAL WELL | 34-133-23614 |
2013-2 | Produced Fluid (in Barrels) | 146.67 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2013-2 | Produced Fluid (in Barrels) | 146.67 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2013-2 | Produced Fluid (in Barrels) | 233.74 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2013-2 | Produced Fluid (in Barrels) | 146.67 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2013-2 | Produced Fluid (in Barrels) | 758.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013-2 | Produced Fluid (in Barrels) | 27.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014-1 | Produced Fluid (in Barrels) | 145.83 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2014-1 | Produced Fluid (in Barrels) | 145.83 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2014-1 | Produced Fluid (in Barrels) | 76.25 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2014-1 | Produced Fluid (in Barrels) | 145.83 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2014-1 | Produced Fluid (in Barrels) | 367.62 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2014-2 | Produced Fluid (in Barrels) | 28.74 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2014-2 | Produced Fluid (in Barrels) | 250.02 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014-2 | Produced Fluid (in Barrels) | 148.74 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2014-2 | Produced Fluid (in Barrels) | 118.90 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2014-2 | Produced Fluid (in Barrels) | 118.93 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2014-2 | Produced Fluid (in Barrels) | 161.24 Bbl | INJECTION DISPOSAL WELL | 34-155-22403 |
2014-2 | Produced Fluid (in Barrels) | 118.90 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2014-2 | Produced Fluid (in Barrels) | 50.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014-2 | Produced Fluid (in Barrels) | 99.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2014-2 | Produced Fluid (in Barrels) | 336.02 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2015-1 | Produced Fluid (in Barrels) | 158.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015-1 | Produced Fluid (in Barrels) | 160.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2015-1 | Produced Fluid (in Barrels) | 177.50 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2015-1 | Produced Fluid (in Barrels) | 157.50 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2015-1 | Produced Fluid (in Barrels) | 25.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23759 |
2015-1 | Produced Fluid (in Barrels) | 75.00 Bbl | INJECTION DISPOSAL WELL | 34-155-24078 |
2015-1 | Produced Fluid (in Barrels) | 77.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015-1 | Produced Fluid (in Barrels) | 443.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 50.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2015-2 | Produced Fluid (in Barrels) | 636.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015-2 | Produced Fluid (in Barrels) | 26.25 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2015-2 | Produced Fluid (in Barrels) | 52.50 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015-2 | Produced Fluid (in Barrels) | 103.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015-2 | Produced Fluid (in Barrels) | 310.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 177.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 816.25 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 10.50 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3097 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 10.50 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3177 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 10.50 Bbl | INJECTION DISPOSAL WELL | 34-007-2-3692 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 52.50 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 10.50 Bbl | INJECTION DISPOSAL WELL | 34-007-23262 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 10.50 Bbl | INJECTION DISPOSAL WELL | 34-007-24355 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 103.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 942.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 173.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 27.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 160.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 81.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 26.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 136.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 82.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 83.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-07 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 12.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 157.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 3.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 113.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 147.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 165.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 167.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 25.00 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 77.50 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 82.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 163.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 135.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 175.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 185.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 51.25 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 62.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 78.75 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 122.50 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 26.25 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 155.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 196.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 26.25 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 207.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 32.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 52.50 Bbl | INJECTION DISPOSAL WELL | 34-007-21847 |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 137.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 81.25 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 120.96 Tons | LANDFILL | 301358 |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1882372 | Primary Facility | 05/06/2010 | Routine/Partial Inspection | Violation(s) Noted | No site ID sign, accelerated erosion, pit and impoundment not above SHWT, impoundment has holes in liner, waste burried in soil stockpile, drilling mud on ground |
1884249 | Primary Facility | 05/13/2010 | Compliance Evaluation | Violation(s) Noted | Accelerated erosion, drilling mud on ground, drill pit not 20 inches above SHWT |
1886368 | Primary Facility | 05/19/2010 | Compliance Evaluation | No Violations Noted | |
1891980 | Primary Facility | 06/16/2010 | Drilling/Alteration | No Violations Noted | |
1895650 | Primary Facility | 07/01/2010 | Drilling/Alteration | No Violations Noted | |
1928109 | Primary Facility | 11/12/2010 | Routine/Partial Inspection | No Violations Noted | |
2016924 | Primary Facility | 11/02/2011 | Routine/Complete Inspection | No Violations Noted | An inspection was conducted at the Pine Hill Pad A site on 11/2/11. The E&S plan and site perimeter were observed. The wells is production and the site was stable. No violations were cited during this inspection. - MRN |
2103014 | Primary Facility | 09/12/2012 | Routine/Complete Inspection | No Violations Noted | |
2146943 | Primary Facility | 03/11/2013 | Site Restoration | No Violations Noted | An inspection of the Pine Hill Pad A in Wharton township, Potter County was conducted on March 11, 2013 in response to a Well Site Restoration Reports received by the Department (for wells 1941, 2143, 2414 and 2415) . The site was determined to meet the requirements of 25 Pa Code §102.22(a)(2) (i) Permanent Stabilization. A minimum uniform 70% perennial vegetative cover, with a density capable of resisting accelerated erosion and sedimentation was observed. The Restoration reports were deemed approved. No violations were cited during this inspection. |
2364548 | Primary Facility | 04/20/2015 | Routine/Complete Inspection | No Violations Noted | |
2461451 | Primary Facility | 2016-03-04 | Routine/Complete Inspection | No Violations Noted | Routine inspection. Four wells have been drilled. Site is restored. Pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations cited. TLT |
2576295 | Primary Facility | 2017-03-28 | Routine/Complete Inspection | No Violations Noted | |
2687446 | Primary Facility | 2018-01-26 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. The wellhead assembly all fittings all flow lines and the cellar area were tested for gas. Results of this testing was no gas was detected on the wellhead assembly or the well area. |
2722132 | Primary Facility | 2018-04-24 | Routine/Complete Inspection | No Violations Noted | Four wells have been drilled. The site is restored per the requirements of post-drilling restoration The impervious area of the pad has been minimized and disturbed areas permanently stabilized. No temporary E&S controls remain. No violations were noted during this inspection |
2737862 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. |
2802442 | Primary Facility | 2018-11-09 | Administrative/File Review | No Violations Noted | Admin inspection for purpose of linking to a plugging COA. |
2823895 | Primary Facility | 2019-01-09 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was in production. There was no gauge on the approximate 3" flow line. This well has the annular vents hard piped /plumbed to the waste/ production tanks that are in a steel walled containment. No violations were noted at this inspection. |
2833832 | Primary Facility | 2019-01-30 | Incident- Response to Accident or Event | Violation(s) Noted | The DEP conducted an incident inspection of PGE's Pine Hill 1941 Well Pad in Wharton Twp, Potter County on 1/30/2019 at 1215 hours. The inspection was conducted in response to a spill reported to the DEP Report hotline by Nathan Harris (PGE). It was reported that at approximately 0900 a vac truck that was moving produced water from a production tank had "collapsed". The tank was estimated to have had 25 barrels of liquid inside when it collapsed.
DEP WQS, Jonathan Pennings and I arrived onsite at 1215 hours. When we arrived the truck was still in place and crew was observed sucking up fluids from the pad surface. We observed the vac truck(see photo #1) and the impacted area (photo #2 & 14). Puddles and slush mixes were field measured with a PCSTestr returning readings ranging from ~2.0 ms/cm to ~15.0 ms/cm (see photos #3, 4 & 5). We spoke with Erick Duzick (PGE Completions Engineer) onsite who explained the vac trucks relief valve was frozen solid which had caused the truck to create a vacuum which in ret |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1882372 | 586503 | 05/06/2010 | 05/19/2010 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1882372 | 586504 | 05/06/2010 | 05/19/2010 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative | |
1882372 | 586505 | 05/06/2010 | 05/19/2010 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | |
1882372 | 586506 | 05/06/2010 | 05/19/2010 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | 35 PS 691.402 |
1882372 | 586507 | 05/06/2010 | 05/19/2010 | 51017 - Administrative Code-General | Administrative | 35 PS 6018.301 |
1884249 | 586957 | 05/13/2010 | 05/19/2010 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
1884249 | 586958 | 05/13/2010 | 05/19/2010 | 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table | Administrative | |
1884249 | 586959 | 05/13/2010 | 05/19/2010 | 401 CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | 35 PS 691.402 |
1884249 | 586960 | 05/13/2010 | 05/19/2010 | 51017 - Administrative Code-General | Administrative | 35 PS 6018.301 |
2833832 | 840719 | 2019-01-30 | CSL 402(b) | Environmental Health & Safety | The release of a regulated substance to the pad surface is in violation of CSL 402(b) for the potential to pollute the waters of the Commonwealth. | |
2833832 | 840720 | 2019-01-30 | 78a57(a) | Environmental Health & Safety | The release of the regulated substance to the pad surface is in violation of 25 Pa Code Section 78a57(a) for failure to collect fluids producing during operation of a well in a tank or other container approved by the Department. | |
2833832 | 840721 | 2019-01-30 | SWMA 301 | Environmental Health & Safety | The release of the regulated substance to the pad surface is in violation of SWMA 301 regarding transport, storage or disposal of residual waste inconsistent with Department regulations. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
840719 | 371900 | NOV - Notice of Violation | |||||
840720 | 371900 | NOV - Notice of Violation | |||||
840721 | 371900 | NOV - Notice of Violation |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/21/2010 | 09/21/2010 | 6200.0 | 6169894.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand | Superior Well Services | Proppant | Crystalline Silica (quartz) | 14808-60-7 | 100.0 | 12.7455 | |
AI -2 | Superior Well Services | Acid Inhibitor | Glycol Ether | 111-76-2 | 30.0 | 0.00008000 | ||
WFR-3B | Superior Well Services | Friction Reducer | Hydrotreated Light Distillate | 64742-47-8 | 30.0 | 0.02228 | ||
Water* | PGE | Carrier/Base Fluid | 7732-18-5 | 100.0 | 85.9211 | |||
Acid, Hydrochloric (3) | Superior Well Services | Solvent | Hydrochloric Acid | 7647-01-0 | 3.0 | 0.03712 | ||
Propargyl Alcohol | 107-19-7 | 30.0 | 0.00008000 | |||||
Isopropyl Alcohol | 67-63-0 | 30.0 | 0.00008000 | |||||
Ethoxylated Alcohols | 68551-12-2 | 4.0 | 0.00297 | |||||
Diethylene Glycol | 111-46-6 | 3.5 | 0.00036 | |||||
Propylene Glycol | 57-55-6 | 25.0 | 0.01857 | |||||
Anionic copolymer | Proprietary | 10.0 | 0.00112 | |||||
Mineral Spirits | 8052-41-3 | 10.0 | 0.00743 | |||||
Anionic polymer | Proprietary | 10.0 | 0.00112 | |||||
Polyethylene Glycol | 25322-68-3 | 50.0 | 0.00519 | |||||
2-Phosphonobutane-1,2,4 tricarboxylic acid | 37971-36-1 | 10.0 | 0.00112 | |||||
Proprietary Component | Proprietary | 7.0 | 0.00002000 | |||||
Ethylene Glycol | 107-21-1 | 1.0 | 0.01037 | |||||
Super TSC | Superior Well Services | Scale Inhibitor | Propylene glycol | 57-55-6 | 50.0 | 0.0056 | ||
KR-153SL | Superior Well Services | Biocide | 2,2-Dibromo-3-nitrilo-propionamide | 10222-01-2 | 20.0 | 0.00207 |
For data sources see[7]