If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-113-20366 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.564219,"lon":-76.513408,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Sullivan | |
Municipality: Forks Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 153025 | |
Farm/Lease Name: BAHL UNIT 2H | |
License Status: Active | |
Spud Date: 03/01/2017 | |
Permit Date: 2/9/2017 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.564219 | |
Longitude: -76.513408 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | CHIEF OIL & GAS LLC | 1,430,316.21 | 171 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 2,170,163.99 | 362 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 456,934.62 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2017-03 | Drill Cuttings (in Tons) RWC 810 | 457.26 Tons | LANDFILL | 301358 |
2017-04 | Drill Cuttings (in Tons) RWC 810 | 857.43 Tons | LANDFILL | 301358 |
2017-04 | Drilling Fluid Waste (in Barrels) RWC 803 | 600.86 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 7,977.08 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 985.74 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 576.16 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 114.95 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 106.42 Bbl | REUSE (AT WELL PAD) | |
2017-12 | Produced Fluid (in Barrels) RWC 802 | 206.25 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 232.05 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 183.72 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 183.73 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 51.37 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 92.67 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 91.01 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 91.84 Bbl | REUSE (AT WELL PAD) | |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 57.61 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 40.10 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2563244 | Primary Facility | 2017-02-21 | Routine/Complete Inspection | No Violations Noted | No violations cited. |
2572249 | Primary Facility | 2017-03-13 | Drilling/Alteration | No Violations Noted | Arrived @ 13:49. Weather: cloudy, snow storm predicted. Site being prepared for drilling. Containment was down and covered with mats. At the time of my inspection an Allison Crane crew was onsite. Also onsite was a Keystone Clearwater Solutions crew. I spoke to Mark Maguire who said that they were putting OBM from the Yonkin B in the tanks on the right hand side (looking toward the road). They were putting water in the tanks at the back on the left, and base oil in the tank at the front on the left.
The Bahl Unit 1H was shut in and surrounded by fencing. Bahl 2H and Bahl 3H conductors were cut and beveled. Left @ 14:00. |
2574514 | Primary Facility | 2017-03-23 | Routine/Partial Inspection | No Violations Noted | Inspection conducted to assess site conditions during drilling operations. I was accompanied my Chief representative Jeff Browning during my inspection. No violations were cited. |
2575575 | Primary Facility | 2017-03-23 | Drilling/Alteration | No Violations Noted | Arrived @ 11:27. Weather: cloudy. Precision 569 on location. Met with company man Jeff Browning. At the time of my inspection he had just set the pack off and was waiting on the intermediate casing cement. Originally he had been drilling the 2H, but due to anti-collision issues with the completed 1H, the 3H was being drilled from the 2H SHL. Intermediate casing was set at 1590’, used 560 sks, 1.253 yield, 17 bbls return to surface (cement report labeled 3H). Surface casing shoe was set at 558’, 535 sks, 20 bbls returned to surface (cement report labeled 2H). For the 2H, they had been originally set to drill at 2° toward the north to avoid the 1H borehole. Due to the lag in MWD tool reporting, didn’t find out until about 200’ that the well was drifting 2° south. Efforts to get back to the drilling program on track did succeed, so at the time of my inspection, Chief was drilling the 3H from the 2H surface location. Jeff Browning said that he would drill the 3H to kick off @ ¿ 7400’.
Then he would fill the hole |
2580923 | Primary Facility | 2017-03-29 | Drilling/Alteration | No Violations Noted | Weather: cold, windy overcast. Arrived @ 11:45, following a reconnaissance of the nearby abandoned well, which is described in the later part of this inspection report. Precision 569 on location. Met with company man Justin Ford. The surface casing cement job had recently been completed, so they were waiting on cement. The surface casing shoe was set at: 552’, Surface cement job: 560 sks of cement, with a yield of 1.19 cubic feet/sk, and 28 bbls cement return. Like the 3H, drilling for this well was also deviated from the start, using the same bend as previously used on the 3H, but a bigger motor. The deviation went well. No violations were observed during my inspection. Left @ 12:10.
Weather: cold, windy overcast. Arrived @ 11:45, following a reconnaissance of the nearby abandoned well, which is described in the later part of this inspection report. Precision 569 on location. Met with company man Justin Ford. The surface casing cement job had recently been completed, so they were waiting on cement. The sur |
2582449 | Primary Facility | 2017-04-13 | Routine/Complete Inspection | No Violations Noted | Inspection to assess site conditions during drilling operations. No violations cited. |
2586736 | Primary Facility | 2017-04-25 | Routine/Complete Inspection | No Violations Noted | Drilling completed. Well development containment removed. Rig matting stacked on side of well site. Various storage containers remain on site. No violations noted. |
2602959 | Primary Facility | 2017-06-09 | Administrative/File Review | Violation(s) Noted | |
2606786 | Primary Facility | 2017-06-15 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: Cloudy, cooler. Arrived @ 14:00 accompanied by Jon Hafer. The purpose of this inspection was to check on the pressure gauges installed on the 13-3/8” x 9-5/8” annuli of the Bahl 2H and Bahl 3H wells. Bubbling outside of surface casing on these wells was reported by Chief on 6/7/17. At the time of my inspection the Bahl 2H and 3H were being zipper-fracced. The 5-1/2” x 9-5/8” annulus was linked to the frac plumbing and monitored for major changes in flow. The 13-3/8” x 9-5/8” annuli were shut-in to continuous pressure monitors. Also in-line was an analog pressure gauge and a pressure relief valve set to release if pressures approached the regulatory limit.
Bahl 2H: 9-5/8” x 5-1/2”, very low, less than 5 psi, bubbling outside of the surface casing was observed. Bahl 3H: 9-5/8” x 5-1/2”: 34 psi, bubbling ouside of the surface casing was observed. Following the inspection of the Bahl 2H and 3H wells, the abandoned well well at: 41.56751, -76.50944, off Bahl Rd was monitored. The casing was monitore |
2606830 | Primary Facility | 2017-06-20 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: Pleasant. Arrived @ 14:00 accompanied by Chief Environmental Specialist Jon Hafer. The purpose of this inspection was to check on the pressure gauges installed on the 13-3/8” x 9-5/8” annuli of the Bahl 2H and Bahl 3H wells. Bubbling outside of surface casing on these wells was reported by Chief on 6/7/17. At the time of my inspection the Bahl 1H was being fracced. The 5-1/2” x 9-5/8” annulus was linked to the frac plumbing and monitored for major changes in flow. The 13-3/8” x 9-5/8” annuli were shut-in to continuous pressure monitors. Also in-line was an analog pressure gauge and a pressure relief valve set to release if pressures approached the regulatory limit.
Bahl 2H: 9-5/8” x 5-1/2”, very low, less than 5 psi, bubbling outside of the surface casing was observed. Bahl 3H: 9-5/8” x 5-1/2”: 36 psi, bubbling outside of the surface casing was observed. Following the inspection of the Bahl 2H and 3H wells, the abandoned well well at: 41.56751, -76.50944, off Bahl Rd was monitored. The casing was |
2608462 | Primary Facility | 2017-06-27 | Routine/Complete Inspection | No Violations Noted | I arrived on-site @ 09:20 hrs. and met Justin Myers, Chief company man. Frac ended Sunday 6/25, and most equipment had already been moved to the Nelson pad for the upcoming frac there. Several banks of Baker tanks and a pair of pump trucks were still present on the site. Water puddled on the pad surface demonstrated low conductance (.3- .980 mS/ cm). Berms had been removed from pad containment for equipment removal; water puddled on the liner also mostly showed low conductance (.4- 1.3 mS/ cm); however, one area near the pump trucks had puddles ranging from 2 mS/cm to greater than 19.99 mS/ cm. The volume of these puddles were low (the largest being 2-3 gallons), and a vac truck operator was immediately deployed to the area by Mr. Myers. Overall condition of the pad liner appeared to be good. PPC and ER plan were in the site mailbox; I departed the site @ 10:15 hrs. |
2614876 | Primary Facility | 2017-07-11 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: cloudy, threat of rain. Arrived @ 12:10 accompanied by Chief Environmental Specialist Jon Hafer. The purpose of this inspection was to document the start of a PBT test on the 13-3/8” x 9-5/8” and 9-5/8” x 5-1/2” annuli of the Bahl 2H and Bahl 3H wells. The test was motivated by an anomaly in pressure data for the 13-3/8” x 9-5/8” annulus of the Bahl 3H during fraccing operations on the Bahl pad (2H, 3H, 1H). Pressures on this annulus on 6/20/17 increased from 35 psig to 71 psig on 6/25/17 when the test was terminated. At the time of my inspection, preparations were being made to drill out plugs. The 9-5/8” x 5-1/2” annuli were shut in and the 13-3/8” x 9-5/8” annuli were open and venting. Since the 9-5/8” x 5-1/2” annuli were not at open equilibrium prior to the start of the test, we agreed to only gather pressure data only on the 13-3/8” x 9-5/8” annuli. The start time for the Bahl 3H was
Was 12:45 and the 0 recording was taken while off line. The start time for the Bahl 2H was 12:52. |
2616836 | Primary Facility | 2017-07-17 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: hot. Arrived @ 11:00 accompanied by Chief Environmental Specialist Jon Hafer. The purpose of this inspection was to check on the pressure build for 13-3/8” x 9-5/8” annuli of the Bahl 2H and Bahl 3H wells which begain on 7/11/17. At the time of my inspection the three wells on this pad (Bahl 1H, 2H, and 3H) were in production. The 9-5/8” x 5-1/2” annuli were shut-in, but not being monitored. For the Bahl 2H, the bubbling in the 20” x 13-3/8” annulus was sporatic and appeared similar to previous observations on 7/11/17 and earlier. On 7/17/17 the pressure on the 13-3/8” x 9-5/8” was 9.3 psi at 12:10 and 33°C. As the inspection terminated a crew arrived on site to open the annular vents and plumb them to a polytank. |
2624339 | Primary Facility | 2017-08-03 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: cloudy, after rain. Arrived @ 10:30 to meet Chief Environmental Specialist Jon Hafer to conclude 7-day PBTs on the Bahl Unit 2H and 3H. At the time of my inspection the three wells on this pad (Bahl 1H, 2H, and 3H) were in production. Pressures at the conclusion of the test were as follows:
Bahl Unit 2H: 9-5/8” X 5-1/2”: 590.10 psig @ 12:10; 13-3/8” x 9-5/8”: 9.10 psig @ 12:10, 20” x 13-3/8”: 12.75 psig @ 12:15. 5-1/2” 1600 psi (0-5000 psi analog). Bahl Unit 3H: 9-5/8” X 5-1/2”: 645.60 psig @ 11:15; 13-3/8” x 9-5/8”: 54 psig @ 12:00, 20” x 13-3/8”: 24.55 psig @ 12:05. 5-1/2” : 1800 psi (0-5000 psi analog). Made plans with Mr Hafer to isolate, purge, briefly shut-in, and collect isotopic samples on 8/7/17. |
2624558 | Primary Facility | 2017-08-07 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Weather: rain. Arrived @ 9:48 with Chief Environmental Specialist Jon Hafer to observe and participate in split isotopic sample collection from annuli on the Bahl Unit 2H and 3H. At the time of my inspection the three wells on this pad (Bahl 1H, 2H, and 3H) were in production. There were no well tags on the Bahl Unit 2H and 3H. Mr Hafer said he would refer this to appropriate Chief staff.
Bahl 2H: there was very little gas on the 13-3/8” x 9-5/8” annular vent, which was making clear water. Mr Hafer drained the other vent, and shut-in the annulus so that we could return to sample after visiting the Nelson pad. Split samples were acquired for: 9-5/8” x 5-1/2” @ 10:15, and 20” x 13-3/8” @ 10:25. Top gauge and 5-1/2”: 1600 psi (0-5000 psi, analog). Left location @ 10:33. Returned to the Bahl at 12:10 to try to collect 13-3/8” x 9-5/8” sample. There was only enough gas for 1 bag, which Mr Hafer collected. We left the sampling set up in place, in case the Department wanted to try again later in the week. Andrea |
2670341 | Primary Facility | 2017-11-07 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived at 9:50. Weather cold, cloudy, windy. Andrea Mullen (DEP geologist), Ulyana Trynovich (DEP OGI), and I met with Jon Hafer (Chief Environmental Specialist). There were 3 producing wells on the pad. The purpose of this inspection was to examine the annular plumbing on the 2H and 3H wells (which employ the GE RSH2 well head) and the 1H (which uses the LSH well head), and participate in the acquisition of production gas isotopic samples for the 2H and 3H wells. Following the well inspections, the abandoned well was monitored for combustible gas, but no gas was detected (Altair 5X gas meter calibrated on 11/7/17). During this inspection a crew was working on one of the Bahl pad sediment basins.
The result of this inspection of the Bahl 2H is OUTST, because violations were cited on 06/09/17 (IR#: 2602959), and no new violations were cited during this inspection. Left location @ 11:30. |
2670356 | Primary Facility | 2017-12-06 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived at 9:30. Weather: cold, windy. Met with Jon Hafer for conclusion of Bahl 2H and 3H 168-hour PBTs and isotopic sample acquisition. All 3 wells were in production.
Bahl 2H: 1500 psi top gauge. 20" x 13-3/8": 1.74 psig 13-3/8" x 9-5/8": -.35 psig 9-5/8" x 5-1/2": 519.75 psig. Left at 11:50. |
2695013 | Primary Facility | 2018-02-15 | Routine/Complete Inspection | Outstanding Violations - Viols Req'd | Arrived at 12:30. Weather warm with snow and ice melting. There are 3 wells in production on site and an abandoned well off-site, but nearby. Bahl 1H: ice in cellar, 5' below surface, no bubbles. Top gauge: 1200 psi (0-5000 psi). 5-1/2": 1225 psi (0-5000 psi). 9-5/8" x 5-1/2": 36% methane/ volume (Altair 5X gas meter calibrated 2/14/18).
Bahl 3H: cellar water-filled. Top gauge: 1200 psi, 5-1/2": 1150 psi. Bahl 2H: low level water and ice in cellar. Top gauge: 1150, Bahl 2H and 3H are plumbed to the same polytank. Tank about 1/5 full of oil-based mud mixture. 60% methane/ volume at tank mouth. Nearby abandoned well: some water in base of casing - no bubbling. No methane detected. |
2725846 | Primary Facility | 2018-05-03 | Routine/Complete Inspection | No Violations Noted | Three wells staged for production phase. Four each water separators. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. See E&S issues. No enforcement taken at this time. |
2785654 | Primary Facility | 2018-10-09 | Routine/Complete Inspection | No Violations Noted | Weather was 70° and cloudy at time of inspection. There were no Chief representatives on location at time of inspection. Well had a 0-5k psi gauge on the production tubing, the production casing and the pay line. Well also had a digital gauge on the production casing. The digital gauge on the production casing read 1081 psi, tubing pressure was approximately 1100 psi and pay line pressure was approximately 1200 psi at time of inspection. The analog gauge on the production casing appeared to be broken at time of inspection because it was wrapped around behind the zero pin. There were 2 annulus vents plumbed to surface. They were plumbed together and ran over to a poly vent tank. The tank had 100% LEL and 8% methane detected at time of inspection. No violations were noted at time of inspection. |
2835741 | Primary Facility | 2019-02-04 | Routine/Complete Inspection | No Violations Noted | Arrived onsite for a routine inspection at 12:38; the weather was ~50°F, clear, and calm. The gate was open when I arrived.
There were 3 properly tagged Marcellus wells staged for production. The well cellars were filled with water; no bubbling was observed. The wells were plumbed to 2 poly vent tanks that were not on additional secondary containment. There were 3 GPU's and produced water tanks onsite and in secondary containment. There were 2 infiltration basins constructed at this pad. Both basins had some remaining ice in them. Some areas that were free from snow were well vegetated. Sections of filter sock remained in place around the site. The last logged E&S inspection was 1/14/19. The Department recommends maintaining a proper inspection schedule and noting those inspections in the onsite log. No violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2602959 | 787691 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2602959 | 787692 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2602959 | 787693 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2602959 | 787694 | 2017-06-09 | 2018-10-18 | 78a85(c)2 | Environmental Health & Safety | |
2606786 | 788684 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2606786 | 788685 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2606786 | 788686 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2606786 | 788687 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2606830 | 788702 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2606830 | 788703 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2606830 | 788704 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2606830 | 788705 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2614876 | 791248 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2614876 | 791249 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2614876 | 791250 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2614876 | 791251 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2616836 | 791690 | 2017-06-06 | 78a73(b) | Environmental Health & Safety | ||
2616836 | 791691 | 2017-06-06 | 78a81(a)2 | Environmental Health & Safety | ||
2616836 | 791692 | 2017-06-06 | 78a85(a)5 | Environmental Health & Safety | ||
2616836 | 791693 | 2017-06-06 | 78a85(c)2 | Environmental Health & Safety | ||
2624339 | 793873 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2624339 | 793874 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2624339 | 793875 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2624339 | 793876 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2624558 | 793976 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2624558 | 793977 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2624558 | 793978 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2624558 | 793979 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2670341 | 803925 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2670341 | 803926 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2670341 | 803927 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2670341 | 803928 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2670356 | 803934 | 2017-06-09 | 78a73(b) | Environmental Health & Safety | ||
2670356 | 803935 | 2017-06-09 | 78a81(a)2 | Environmental Health & Safety | ||
2670356 | 803936 | 2017-06-09 | 78a85(a)5 | Environmental Health & Safety | ||
2670356 | 803937 | 2017-06-09 | 78a85(c)2 | Environmental Health & Safety | ||
2695013 | 809023 | 2018-02-15 | 78a73(b) | Environmental Health & Safety | ||
2695013 | 809024 | 2018-02-15 | 78a81(a)2 | Environmental Health & Safety | ||
2695013 | 809025 | 2018-02-15 | 78a85(c)2 | Environmental Health & Safety | ||
2695013 | 809026 | 2018-02-15 | 78a81(a)2 | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
787691 | 354179 | NOV - Notice of Violation | |||||
787692 | 354179 | NOV - Notice of Violation | |||||
787693 | 354179 | NOV - Notice of Violation | |||||
787694 | 354179 | NOV - Notice of Violation | |||||
787694 | 368514 | CACP - Consent Assessment of Civil Penalty | COMP - Completed | 10/18/2018 | 2018-10-18 | $220,000.00 | $220,000.00 |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 06/12/2017 | 06/25/2017 | 7283 | 8,433,730.0 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Water | Chief Oil & Gas | Carrier/Base Fluid | Listed Below | ||||
BIOC 11139A | Nalco Champion | Biocide | Listed Below | |||||
Water | 7732-18-5 | 100 | 85.7791 | 70,379,400.0 | ||||
Formaldehyde | 50-00-0 | 1 | 0.00001000 | 1 | ||||
Ethanol, 2,2',2"-nitrilotris-, tris(dihydrogen phosphate) (ester), sodium salt | 68171-29-9 | 30 | 0.00163 | 1340 | ||||
Thiourea | 62-56-6 | 1 | 0.00001000 | 1 | ||||
Quaternary ammonium compound | 68424-85-1 | 10 | 0.00252 | 2070 | ||||
Water | 7732-18-5 | 80 | 0.02019 | 16563 | ||||
Alcohols, (C10-16), ethoxylated | 68002-97-1 | 5 | 0.00327 | 2685 | ||||
(Mineral oil) Light hydrotreated petroleum distillate | 64742-47-8 | 30 | 0.01964 | 16110 | ||||
Water | 7732-18-5 | 85 | 0.14606 | 119836 | ||||
Ammonium acetate | 631-61-8 | 13 | 0.00851 | 6981 | ||||
Alcohols, C12-14, ethoxylated | 68439-50-9 | 5 | 0.00327 | 2685 | ||||
Ethoxylated (C10-16) alcohols | 68002-97-1 | 35 | 0.00005000 | 41 | ||||
Ethylene glycol | 107-21-1 | 30 | 0.00163 | 1340 | ||||
Diethylene glycol mono-n-butyl ether | 112-34-5 | 60 | 0.00009000 | 71 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.02577 | 21148 | ||||
Methanol, | 67-56-1 | 5 | 0.00001000 | 6 | ||||
Crystallilne silica | 14808-60-7 | 100 | 13.9528 | 11,447,900.0 | ||||
Ethanol | 64-17-5 | 5 | 0.00126 | 1035 | ||||
Water | 7732-18-5 | 40 | 0.00218 | 1786 | ||||
Acetophenone | 98-86-2 | 1 | 0.00001000 | 1 | ||||
Alcohols, C12-16, ethoxylated | 68551-12-2 | 5 | 0.00327 | 2685 | ||||
Glutaraldehyde | 111-30-8 | 5 | 0.00126 | 1035 | ||||
Unihib G | GeoSafe | Acid Inhibitor | Listed Below | |||||
Hydrochloric Acid | PVS | Acidizing | Listed Below | |||||
Unislick ST-50 | CESI Chemical | Friction Reducer | Listed Below | |||||
SCAL 16484A | Nalco Champion | Scale Inhibitor | Listed Below | |||||
Sand | Sargent/Unimin | Proppant | Listed Below |
For data sources see[7]