If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21187 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.702164,"lon":-75.975675,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Auburn Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 144857 | |
Farm/Lease Name: BISHOP UNIT 4H | |
License Status: Active | |
Spud Date: 03/28/2013 | |
Permit Date: 3/20/2013 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.702164 | |
Longitude: -75.975675 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2013 | CHIEF OIL & GAS LLC | 582,308.00 | 63 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,534,317.00 | 337 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 751,641.58 | 326 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 615,828.43 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 569,171.98 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 421,618.62 | 354 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 83,031.31 | 89 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2013-1 | Drill Cuttings (in Tons) | 836.91 Tons | LANDFILL | 100933 |
2013-2 | Fracing Fluid Waste (in Barrels) | 1,996.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 662.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 110.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-1 | Produced Fluid (in Barrels) | 1,828.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 394.52 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 227.01 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 361.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 276.81 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 380.08 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 7.05 Tons | LANDFILL | 301358 |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 97.93 Bbl | REUSE (AT WELL PAD) | |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 91.66 Bbl | REUSE (AT WELL PAD) | |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 97.86 Bbl | REUSE (AT WELL PAD) | |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 87.68 Bbl | REUSE (AT WELL PAD) | |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 70.80 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 61.74 Bbl | REUSE (AT WELL PAD) | |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 72.55 Bbl | REUSE (AT WELL PAD) | |
2017-11 | Produced Fluid (in Barrels) RWC 802 | 62.64 Bbl | REUSE (AT WELL PAD) | |
2018-01 | Produced Fluid (in Barrels) RWC 802 | 53.22 Bbl | REUSE (AT WELL PAD) | |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 40.85 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 70.89 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 65.22 Bbl | REUSE (AT WELL PAD) | |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 107.42 Bbl | REUSE (AT WELL PAD) | |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 42.38 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 21.77 Bbl | REUSE (AT WELL PAD) | |
2019-01 | Produced Fluid (in Barrels) RWC 802 | 13.48 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 37.09 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2164528 | Primary Facility | 05/06/2013 | Drilling/Alteration | No Violations Noted | Conductor set. Notification rec'd of well spud 03/28/13 |
2501365 | Primary Facility | 2016-07-06 | Routine/Complete Inspection | No Violations Noted | |
2726807 | Primary Facility | 2018-05-02 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection of the Bishop well pad. The wells associated with this pad are as follows: 115-21125, 115-21185, 115-21186, 115-21187, 115-21188, 115-21189, 115-21311. The wells were properly labeled.
The access road and pad surface were stable. The cut and fill slopes were stable and well vegetated and the pad surface was quite small. There were no erosional issues apparent during the inspection. There were no violations. |
2800797 | Primary Facility | 2018-11-07 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection on the Bishop well site. The weather was mostly sunny and 48 deg. F. There was previously heavy rain.
The access road was solid and stable and the area to the sides was well vegetated and stable. The well pad surface was puddled due to recent rains but had no erosional issues occurring at the time of inspection. The slopes and the area surrounding the site were well established with perennial grasses. The growth exceeded the 70% vegetative standard required by the Department. There was no evidence of slumping or slope failure at the time of inspection. All temporary BMPs have been removed from the site and there were no indications of any adverse affects due to their removal. The permanent PCSMs were all installed according to plan and appeared to be functioning as intended. The area as a whole was solid, stable and had good growth, with no temporary BMPs remaining and all permanent PCSMs in place. The well pad area was compact and pulled in as m |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 09/11/2013 | 09/14/2013 | 6929 | 4,918,120.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Bactron K-139 | Champion Technologies | Biocide | Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides | 68424-85-1 | 10 | 0.004 | 0 |
Glutaraldehyde | 111-30-8 | 5 | 0.002 | 0 | ||||
Ethanol | 64-17-5 | 5 | 0.002 | 0 | ||||
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 99.88 | 0 | |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.001 | 0 | |
Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.1 | 0 | |
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.02 | 0 |
For data sources see[7]