37-115-21201

Well Details

Well ID: 37-115-21201
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 144892
Farm/Lease Name: HARRIS 5H
License Status: Active
Spud Date: 03/29/2013
Permit Date: 3/4/2013
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.8129
Longitude: -75.751853

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 1,565,253.00 264 0.00 0 0.00 0
2015 SOUTHWESTERN ENERGY PROD CO 1,291,172.00 365 0.00 0 0.00 0
2016 SWN PROD CO LLC 859,561.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 389,231.00 358 0.00 0 0.00 0
2018 SWN PROD CO LLC 485,768.00 334 0.00 0 0.00 0
2019 SWN PROD CO LLC 133,331.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
16APRU Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
16AUGU Produced Fluid (in Barrels) RWC 802 23.00 Bbl REUSE OTHER THAN ROAD SPREADING
16DECU Produced Fluid (in Barrels) RWC 802 84.50 Bbl REUSE OTHER THAN ROAD SPREADING
16FEBU Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JANU Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JULU Produced Fluid (in Barrels) RWC 802 21.00 Bbl REUSE OTHER THAN ROAD SPREADING
16JUNU Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
16MARU Produced Fluid (in Barrels) RWC 802 32.50 Bbl REUSE OTHER THAN ROAD SPREADING
16MAYU Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
16NOVU Produced Fluid (in Barrels) RWC 802 36.33 Bbl REUSE OTHER THAN ROAD SPREADING
16OCTU Produced Fluid (in Barrels) RWC 802 36.66 Bbl REUSE OTHER THAN ROAD SPREADING
16SEPU Produced Fluid (in Barrels) RWC 802 36.33 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Drill Cuttings (in Tons) 1,205.94 Tons LANDFILL 101247
2013-2 Drill Cuttings (in Tons) 321.77 Tons LANDFILL 101247
2013-2 Fracing Fluid Waste (in Barrels) 10.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 143.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracing Fluid Waste (in Barrels) 3,751.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Fracturing Fluid Waste (in Tons) 94.25 Tons LANDFILL THR029
2014-1 Produced Fluid (in Barrels) 3,331.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 52.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 282.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 403.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-01 Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-02 Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-03 Produced Fluid (in Barrels) RWC 802 32.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016-04 Produced Fluid (in Barrels) RWC 802 17.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-05 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-06 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-07 Produced Fluid (in Barrels) RWC 802 21.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-08 Produced Fluid (in Barrels) RWC 802 23.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016-09 Produced Fluid (in Barrels) RWC 802 36.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016-10 Produced Fluid (in Barrels) RWC 802 36.66 Bbl REUSE OTHER THAN ROAD SPREADING
2016-11 Produced Fluid (in Barrels) RWC 802 36.33 Bbl REUSE OTHER THAN ROAD SPREADING
2016-12 Produced Fluid (in Barrels) RWC 802 84.50 Bbl REUSE OTHER THAN ROAD SPREADING
2017-07 Produced Fluid (in Barrels) RWC 802 37.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-08 Produced Fluid (in Barrels) RWC 802 39.17 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-09 Produced Fluid (in Barrels) RWC 802 19.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Barrels) RWC 802 18.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Drilling Fluid Waste (in Barrels) RWC 803 386.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Produced Fluid (in Barrels) RWC 802 37.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Other Oil & Gas Wastes (in Barrels) RWC 899 10.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Produced Fluid (in Barrels) RWC 802 113.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Other Oil & Gas Wastes (in Barrels) RWC 899 21.73 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Produced Fluid (in Barrels) RWC 802 18.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-03 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-03 Produced Fluid (in Barrels) RWC 802 37.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-04 Other Oil & Gas Wastes (in Barrels) RWC 899 44.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-04 Produced Fluid (in Barrels) RWC 802 56.67 Bbl SURFACE IMPOUNDMENT 826342
2018-05 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-05 Produced Fluid (in Barrels) RWC 802 22.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-06 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 19.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-07 Produced Fluid (in Barrels) RWC 802 92.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Other Oil & Gas Wastes (in Barrels) RWC 899 62.44 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 826342
2018-08 Produced Fluid (in Barrels) RWC 802 60.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-09 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-10 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 19.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-11 Produced Fluid (in Barrels) RWC 802 32.67 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 38.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Other Oil & Gas Wastes (in Barrels) RWC 899 3.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Produced Fluid (in Barrels) RWC 802 20.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-02 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-03 Produced Fluid (in Barrels) RWC 802 20.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2164226 Primary Facility 04/11/2013 Drilling/Alteration No Violations Noted Conductor set
2398995 Primary Facility 08/18/2015 Routine/Complete Inspection No Violations Noted
2464388 Primary Facility 2016-03-03 Routine/Complete Inspection No Violations Noted On 3/3/16, the Department conducted an inspection of the SWN RU53 Harris Pad while primarily conducting an inspection of the DTE/Susquehanna Gathering 53-54 Well Connect. The last E&S conducted at this pad was by Ryan Klemish on 3/2/16. The access road developed across the pad LOD for the pipeline construction, along with the pipeline LOD construction has good E&S controls installed. DTE has installed new controls which have been integrated into the well pads controls. Overall, E&S controls look good. All 6 wells associated with this pad are in production. No violations noted.
2477431 Primary Facility 2016-04-22 Routine/Complete Inspection No Violations Noted
2491449 Primary Facility 2016-06-08 Routine/Complete Inspection No Violations Noted
2495867 Primary Facility 2016-06-20 Routine/Complete Inspection No Violations Noted On 6/20/16, the Department met with representatives from SWN to inspect the damage to the retention berm of infiltration area #1 that resulted from the landowner breaching the berm. SWN contacted the Department on 6/15/16 to report the discovery of the damage to the berm. Among the SWN representatives were Mike Deming, Senior Regulatory Analyst, and Rich Gulyas, Construction Supervisor. Also present during the inspection was the land owner. The retention berm had an emergency spillway with a rock spreader and can be described as a small retention basin. The landowner explained that the fence that had been placed around the berm structure was breached by one of his bulls, and that his cattle began entering the basin. The landowner became concerned that his young cattle could enter the basin and possibly drown or get seriously injured. The berm is a permanent structure designed to function throughout the life of the well pad. The breach to the berm is in violation of the permit. This was explained to
2495896 Primary Facility 2016-06-22 Administrative/File Review No Violations Noted On 6/22/16, Mike Deming, SWN Senior Regulatory Analyst contacted the Department to report that the repairs to the infiltration berm that had been damaged by the landowner's cattle breaching the fence had been repaired. Mr. Deming sent a photograph of the repairs that clearly show the repairs have been completed. No further action is required of SWN at this time.
2560850 Primary Facility 2017-02-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00a.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 543psi on the production casing and 467psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 11:55a.m.

2654581 Primary Facility 2017-10-31 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2655081 Primary Facility 2017-10-30 Site Restoration No Violations Noted This inspection was conducted to confirm SWN's assessment that the project meets the minimum requirements for permanent stabilization. The Departments determination is that the site meets the requirements for permit termination.
2759070 Primary Facility 2018-08-01 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2775621 Primary Facility 2018-09-13 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Site has very good permanent stabilization. No E&S issues noted. No violations noted.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 01/17/2014 01/20/2014 6783 4,471,910.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 86.7644 37,519,500.0
Sand (Proppant), DAP-901, DAP-925, DWP-603, BioClear 2000, DWP-NE1, Hydrochloric Acid CWS Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Friction Reducer, Biocide, Non-Emulsifier, Clean Perforations Paraffinic hydrocarbon solvent 64742-47-8 30 0.0133 5753.16
Diallyldimethylammonium chloride 7398-69-8 5 0.00158 684.17
Biotite 1302-27-8 0.1 0.00588 2540.56
Sodium chloride 7647-14-5 1 0 1.68
Calcite 471-34-1 1 0.01615 6985.23
Illite 12173-60-3 1 0.01379 5961.41
Formaldehyde 50-00-0 0.1 0.00002000 8.8
Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.00251 1085.5
Crystalline silica (Quartz) 14808-60-7 100 12.7285 5,504,170.0
Sorbitan monooleate 1338-43-8 5 0.00251 1085.5
Poly(Acrylamide and Adam methyl Chloride) 69418-26-4 40 0.01757 7598.51
Ilmenite 98072-94-7 0.1 0.00511 2207.93
Methanol 67-56-1 60 0.00872 3771.7
Propargyl Alcohol 107-19-7 10 0.00004000 16.78
Polyoxyalkylenes Proprietary 30 0.00012 50.35
Polyethylene Glycol Mixture 25322-68-3 70 0.01217 5262.67
Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt 68607-28-3 40 0.01266 5473.38
Isopropanol 67-63-0 40 0.01266 5473.38
Organic phosphonate 1 Proprietary 30 0.00374 1618.48
Olefin Proprietary 5 0.00002000 8.39
Fatty acids Proprietary 30 0.00012 50.35
Ammonium chloride 12125-02-9 10 0.0015 649.35
Modified thiourea polymer 68527-49-1 30 0.00012 50.35
Hydrochloric acid 7647-01-0 37 0.3488 150831
Acetic acid 64-19-7 1 0.00012 53.95
Goethite 1310-14-1 0.1 0.00741 3205.82
Apatite 64476-38-6 0.1 0.00588 2540.56
Organic phosphonate 2 Proprietary 10 0.00125 539.49
2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 40 0.01217 5262.67
Oxyalkylated polyamine Proprietary 5 0.00062 269.75
Amine salt Proprietary 5 0.00062 269.75

For data sources see[7]

References