X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-031-24787

Well Details

Well ID: 37-031-24787
Loading map...
Country: United States
State: Pennsylvania
County: Clarion
Municipality: Ashland Township
Operator Name: DANNIC ENERGY CORP
Well Pad ID:
Farm/Lease Name: MASTERS 1
License Status: Active
Spud Date: 04/21/2008
Permit Date: 11/2/2007
Unconventional Well: N
Configuration: Vertical Well
Latitude: 41.310008
Longitude: -79.598543

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2007 0.00 0.00 0.00
2008 0.00 0.00 0.00
2009 0.00 0.00 0.00
2010 0.00 0.00 0.00
2011 0.00 0.00 0.00
2012 DANNIC ENERGY CORP 0.00 49.69 211 0.00
2013 DANNIC ENERGY CORP 0.00 26.75 214 0.00
2014 DANNIC ENERGY CORP 0.00 16.41 61 0.00
2015 DANNIC ENERGY CORP 0.00 30.17 122 0.00
2016 DANNIC ENERGY CORP 0.00 13.00 366 0.00
2017 DANNIC ENERGY CORP 0.00 5.00 365 0.00
2018 DANNIC ENERGY CORP 0.00 6.30 365 0.00

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-0 Produced Fluid (in Barrels) 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0020346
2010-0 Produced Fluid (in Barrels) 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0028428
2011-0 Produced Fluid (in Barrels) 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0028428
2013-0 Produced Fluid (in Barrels) 80.00 Bbl PUBLIC SEWAGE TREATMENT PLANT PA0028428

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1702029 Primary Facility 04/24/2008 Drilling/Alteration No Violations Noted
1705487 Primary Facility 05/09/2008 Routine/Complete Inspection Violation(s) Noted
1758737 Primary Facility 12/11/2008 Site Restoration Violation(s) Noted
1758856 Primary Facility 12/15/2008 Routine/Complete Inspection Violation(s) Noted
1771624 Primary Facility 02/24/2009 Site Restoration Outstanding Violations - No Viols Req'd
1795346 Primary Facility 04/29/2009 Site Restoration Violation(s) Noted
1818659 Primary Facility 07/29/2009 Site Restoration No Violations Noted
1904485 Primary Facility 08/04/2010 Routine/Complete Inspection No Violations Noted
2100318 Primary Facility 09/10/2012 Routine/Complete Inspection No Violations Noted
2626382 Primary Facility 2017-08-17 Routine/Partial Inspection No Violations Noted Well is equipped for production. Pipelines connected to tubing and surface casing. Both pipelines have check valves installed at the wellsite. Appears to have some minor fluid that leaked from the stuffing box. No pump jack installed at well.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1705487 538743 05/09/2008 04/29/2009 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1705487 538744 05/09/2008 04/29/2009 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling Administrative
1758737 553367 12/11/2008 04/29/2009 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
1758737 553368 12/11/2008 04/29/2009 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1758737 553369 12/11/2008 04/29/2009 78.64 - Inadequate containment of oil tank Administrative
1758856 553398 12/15/2008 06/26/2013 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
1758856 553399 12/15/2008 06/26/2013 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
1795346 562008 04/29/2009 07/29/2009 102.4INADPLN - E&S Plan not adequate Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
538743 233812 NOV - Notice of Violation Comply/Closed 04/29/2009
538744 233812 NOV - Notice of Violation Comply/Closed 04/29/2009
553367 241733 NOV - Notice of Violation Comply/Closed 05/08/2009
553368 241733 NOV - Notice of Violation Comply/Closed 05/08/2009
553369 241733 NOV - Notice of Violation Comply/Closed 05/08/2009
562008 246575 NOV - Notice of Violation Comply/Closed 08/26/2009

For data sources see[6]