Well Details

Well ID: 37-115-22218
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jackson Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 146202
Farm/Lease Name: BOMAN 6H
License Status: Active
Spud Date: 05/11/2017
Permit Date: 9/23/2016
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.853611
Longitude: -75.596033

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SWN PROD CO LLC 5,460.00 1 0.00 0 0.00 0
2018 SWN PROD CO LLC 2,027,395.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 281,894.00 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2017-05 Drill Cuttings (in Tons) RWC 810 70.65 Tons LANDFILL 101247
2017-06 Other Oil & Gas Wastes (in Barrels) RWC 899 220.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-06 Produced Fluid (in Barrels) RWC 802 110.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Drill Cuttings (in Tons) RWC 810 109.26 Tons LANDFILL 101247
2017-07 Drilling Fluid Waste (in Barrels) RWC 803 1,910.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 16.00 Bbl REUSE (AT WELL PAD)
2017-07 Other Oil & Gas Wastes (in Barrels) RWC 899 53.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-08 Other Oil & Gas Wastes (in Barrels) RWC 899 179.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-09 Drill Cuttings (in Tons) RWC 810 373.92 Tons LANDFILL 101247
2017-09 Other Oil & Gas Wastes (in Barrels) RWC 899 79.17 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Drill Cuttings (in Tons) RWC 810 148.17 Tons LANDFILL 101247
2017-10 Drilling Fluid Waste (in Barrels) RWC 803 1,685.00 Bbl REUSE (AT WELL PAD)
2017-10 Other Oil & Gas Wastes (in Barrels) RWC 899 54.17 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Produced Fluid (in Barrels) RWC 802 19.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-10 Synthetic Liner Materials (in Tons) RWC 806 0.22 Tons LANDFILL 101247
2017-11 Other Oil & Gas Wastes (in Barrels) RWC 899 56.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-11 Synthetic Liner Materials (in Tons) RWC 806 1.50 Tons LANDFILL 101247
2017-12 Other Oil & Gas Wastes (in Barrels) RWC 899 66.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-12 Produced Fluid (in Barrels) RWC 802 351.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017-12 Synthetic Liner Materials (in Tons) RWC 806 6.33 Tons LANDFILL 101247
2017-12 Unused Fracturing Fluid Waste (in Tons) RWC 805 2.57 Tons LANDFILL 301358
2017-12 Unused Fracturing Fluid Waste (in Tons) RWC 805 32.00 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-01 Other Oil & Gas Wastes (in Barrels) RWC 899 20.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-01 Produced Fluid (in Barrels) RWC 802 2,848.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-01 Produced Fluid (in Tons) RWC 802 11.14 Tons LANDFILL 301358
2018-02 Other Oil & Gas Wastes (in Barrels) RWC 899 21.73 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-02 Produced Fluid (in Barrels) RWC 802 27.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-02 Produced Fluid (in Barrels) RWC 802 1,282.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-03 Filter Socks (in Tons) RWC 812 0.04 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2018-03 Produced Fluid (in Barrels) RWC 802 135.50 Bbl SURFACE IMPOUNDMENT 826342
2018-03 Produced Fluid (in Barrels) RWC 802 392.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-04 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl SURFACE IMPOUNDMENT 826342
2018-04 Produced Fluid (in Barrels) RWC 802 80.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-04 Produced Fluid (in Barrels) RWC 802 310.67 Bbl SURFACE IMPOUNDMENT 826342
2018-05 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-05 Produced Fluid (in Barrels) RWC 802 75.00 Bbl SURFACE IMPOUNDMENT 826342
2018-05 Produced Fluid (in Barrels) RWC 802 157.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-06 Produced Fluid (in Barrels) RWC 802 74.67 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 84.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-07 Produced Fluid (in Barrels) RWC 802 134.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Other Oil & Gas Wastes (in Barrels) RWC 899 63.34 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-08 Produced Fluid (in Barrels) RWC 802 135.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-09 Other Oil & Gas Wastes (in Tons) RWC 899 38.33 Tons SURFACE IMPOUNDMENT 95-16-65420-013
2018-09 Produced Fluid (in Barrels) RWC 802 94.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-10 Other Oil & Gas Wastes (in Barrels) RWC 899 18.33 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 40.00 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-11 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 826342
2018-11 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018-12 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-12 Produced Fluid (in Barrels) RWC 802 36.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Other Oil & Gas Wastes (in Barrels) RWC 899 3.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-01 Produced Fluid (in Barrels) RWC 802 18.33 Bbl SURFACE IMPOUNDMENT 826342
2019-01 Produced Fluid (in Barrels) RWC 802 37.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-02 Produced Fluid (in Barrels) RWC 802 56.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019-03 Produced Fluid (in Barrels) RWC 802 53.50 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2593824 Primary Facility 2017-05-15 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 8:45a.m. for a new spud inspection.

Minichi Contracting Group was on site and putting in the cellars. Minichi Contracting Group drilled the holes and ran the conductor pipe with a dual rotary rig on the 2H, 3H, 4H, 5H, and 6H wells. I spoke with driller Keith Bowman of Minichi, all the conductors were drilled and set at 88'. The drill cuttings were put into a sealed role off container and hauled to the Keystone Landfill. I took a walk around the location and there were no obvious concerns noticed. I left the site at 9:05a.m.

2612733 Primary Facility 2017-07-06 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 9:25a.m.

I met with company man Kevin Heathcock. Falcon Rig 25 was on site and finished drilling out the shoe of the intermediate casing, they were pulling the drill pipe up to 600' to load the hole with water and do their fit test. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 1,625'. The projected TD for the top-hole section of the well is 5,800'. I left the site at 10:55a.m.

2639074 Primary Facility 2017-08-15 Routine/Complete Inspection No Violations Noted
2641883 Primary Facility 2017-09-29 Drilling/Alteration No Violations Noted At time of inspection.

Met with company man John Woodburn. SDC 45 was on site and drilling the lateral section of the well for the production casing. The top-hole section of the well was drilled and completed by Falcon 25 on 7/9/17. The proposed TD for the well is 11,692'. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2659226 Primary Facility 2017-11-02 Routine/Complete Inspection No Violations Noted I arrived at the site at 11:22. I met with Mike Deming, Senior Regulatory Analyst and Frank Kelly Containment Coordinator both of SWNPC and Chris Anderson of Well Water Solutions. Mr. Anderson and Mr. Deming informed me the following. "Construction of the tank started yesterday. The inner tank is completed. The are (2) liners on the inner tank and (1) on the outer. Geotextile felt, (8) ounces, is on the seam of the tank walls. Geotextile felt is also on the pad surface at the bottom of the tanks, with (3) liners set in place on top of it. We still have to finish pulling the liner over the outer tank yet. The water will go from a valve cellar on the pad through a (12) inch high density polyethylene line made of plastic material and then will be pumped into the tank. The water transferred into the tank is pumped from nearby well development impoundments and the nearby Zeffer centralized wastewater impoundment through underground pipelines to the valve cellar in the corner of the pad at the base of the cut slop
2665873 Primary Facility 2017-11-28 Routine/Complete Inspection No Violations Noted At time of inspection.

I met with company man Chris Henry. USWS (U. S. Well Services) was on site to frac the 2H, 3H, 4H, 5H, and 6H wells. They finished running the plug and perf after stage 2 and were preparing to frac stage 3 out of 24 stages on the 2H. The 3H was completed with 26 stages. The 4H was completed with 22 stages. The 5H was completed with 21 stages. The 6H was completed with 28 stages. The water was being pumped to the location from the Young fresh water impoundment. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2676343 Primary Facility 2017-12-27 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Crews on-site installing new containment. Good well pad stabilization. No violations were noted.
2688030 Primary Facility 2018-01-23 Incident- Response to Accident or Event No Violations Noted Today's inspection was conducted as an incident inspection. At approximately noon today, Mike Deming, SWN Senior Regulatory Analyst contacted the Department to inform the Department that SWN had identified stormwater discharges off of secondary containment on 3 of their pads, of which this pad is one. Present during the inspection was Dillon Otten, SWN Regulatory Analyst. The Department metered for conductivity on the outside of the containment and had readings ranging from 40 uS to 255 uS. Standing water inside containment was read at 60 uS at the lowest point of containment where a discharge had occurred. 6 empty water tanks located on containment. No E&S violations were noted. No violations were observed.
2722779 Primary Facility 2018-04-23 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2824279 Primary Facility 2019-01-09 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/13/2017 11/17/2017 6782 6,058,480.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFRA-2000 U.S. Well Services, LLC Friction Reducer Water 7732-18-5 60 0.04837 28768
2-Propenoic acid, polymer with 2 propenamide 9003-06-9 30 0.02418 14384
Hydrated light distillate (petroleum) 64742-47-8 30 0.01983 11794.9
AI-303 U.S. Well Services, LLC Acid Corrosion Inhibitors Acetophenone,thiourea,formaldehyde polymer 68527-49-1 5 0.00002000 10.008
Formic acid 64-18-6 20 0.00007000 40.032
Ethylene glycol 107-21-1 40 0.00019 114.492
Polyether 60828-78-6 10 0.00003000 20.016
Cinnamaldehyde 104-55-2 20 0.00007000 41.3931
Butyl cellosolve 111-76-2 20 0.00006000 36.0688
Water Southwestern Energy Carrier/Base Fluid Water 7732-18-5 100 84.9558 50,527,700.0
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 17.5 0.10461 62218.5
Water 7732-18-5 87.4 0.44995 267609
K-BAC 1005 U.S. Well Services, LLC Anti-Bacterial Agent 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5.76 0.00161 954.889
Polyethylene Glycol 25322-68-3 50 0.00637 3787.69
Water 7732-18-5 44.3 0.00504 2996.34
SI-1200 U.S. Well Services, LLC Scale Inhibitor Ethylene Glycol 107-21-1 40 0.00764 4541.5
Ammonia 7664-41-7 0.5 0.0001 60.7385
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 14.376 8,550,180.0

For data sources see[7]