{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.91875,"lon":-77.283642,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Farmington Township | |
Operator Name: UGI STORAGE CO | |
Well Pad ID: | |
Farm/Lease Name: HOYT #2 (TW 103) 2147 | |
License Status: Plugged OG Well | |
Spud Date: 1/1/1800 | |
Permit Date: | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Latitude: 41.918750 | |
Longitude: -77.283642 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1991 | 0.00 | 0.00 | 0.00 | ||||
1995 | 0.00 | 0.00 | 0.00 | ||||
1996 | 0.00 | 0.00 | 0.00 | ||||
2017 | 0.00 | 0.00 | 0.00 |
For data sources see[4]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1066056 | Primary Facility | 10/04/2001 | Routine/Complete Inspection | No Violations Noted | |
1085748 | Primary Facility | 12/19/2001 | Routine/Complete Inspection | No Violations Noted | |
1086324 | Primary Facility | 12/27/2001 | Routine/Complete Inspection | No Violations Noted | |
1107986 | Primary Facility | 03/13/2002 | Routine/Complete Inspection | No Violations Noted | |
1179625 | Primary Facility | 10/22/2002 | Routine/Complete Inspection | No Violations Noted | |
1179626 | Primary Facility | 10/22/2002 | Routine/Complete Inspection | No Violations Noted | |
1384285 | Primary Facility | 10/05/2004 | Routine/Complete Inspection | No Violations Noted | |
1436099 | Primary Facility | 03/17/2005 | Routine/Complete Inspection | No Violations Noted | |
1490059 | Primary Facility | 10/25/2005 | Routine/Complete Inspection | No Violations Noted | |
1490076 | Primary Facility | 10/21/2005 | Routine/Complete Inspection | No Violations Noted | |
1493228 | Primary Facility | 11/01/2005 | Routine/Complete Inspection | No Violations Noted | |
1493293 | Primary Facility | 11/02/2005 | Routine/Complete Inspection | No Violations Noted | |
1497827 | Primary Facility | 11/21/2005 | Routine/Complete Inspection | No Violations Noted | |
1497846 | Primary Facility | 11/07/2005 | Routine/Complete Inspection | No Violations Noted | |
1499843 | Primary Facility | 12/01/2005 | Routine/Complete Inspection | No Violations Noted | |
1504786 | Primary Facility | 01/03/2006 | Routine/Complete Inspection | No Violations Noted | |
1508954 | Primary Facility | 01/20/2006 | Routine/Complete Inspection | No Violations Noted | |
1508963 | Primary Facility | 01/23/2006 | Routine/Complete Inspection | No Violations Noted | |
1509782 | Primary Facility | 01/26/2006 | Routine/Complete Inspection | No Violations Noted | |
1512211 | Primary Facility | 02/03/2006 | Routine/Complete Inspection | No Violations Noted | |
1513776 | Primary Facility | 02/06/2006 | Routine/Complete Inspection | No Violations Noted | |
1514471 | Primary Facility | 02/10/2006 | Routine/Complete Inspection | No Violations Noted | |
1514487 | Primary Facility | 02/08/2006 | Routine/Complete Inspection | No Violations Noted | |
1517874 | Primary Facility | 02/20/2006 | Routine/Complete Inspection | No Violations Noted | |
1522283 | Primary Facility | 03/13/2006 | Routine/Complete Inspection | No Violations Noted | |
1523966 | Primary Facility | 03/16/2006 | Routine/Complete Inspection | No Violations Noted | |
1532218 | Primary Facility | 04/24/2006 | Routine/Complete Inspection | No Violations Noted | |
1533710 | Primary Facility | 05/02/2006 | Routine/Complete Inspection | No Violations Noted | |
1559446 | Primary Facility | 08/22/2006 | Routine/Complete Inspection | No Violations Noted | |
1569106 | Primary Facility | 10/03/2006 | Routine/Complete Inspection | No Violations Noted | |
1576576 | Primary Facility | 11/02/2006 | Routine/Complete Inspection | No Violations Noted | |
1578626 | Primary Facility | 11/07/2006 | Routine/Complete Inspection | No Violations Noted | |
1587267 | Primary Facility | 12/12/2006 | Routine/Complete Inspection | No Violations Noted | |
1587449 | Primary Facility | 12/20/2006 | Routine/Complete Inspection | No Violations Noted | |
1590330 | Primary Facility | 01/04/2007 | Routine/Complete Inspection | No Violations Noted | |
1593008 | Primary Facility | 01/12/2007 | Routine/Complete Inspection | No Violations Noted | |
1593010 | Primary Facility | 01/11/2007 | Routine/Complete Inspection | No Violations Noted | |
1594285 | Primary Facility | 01/19/2007 | Routine/Complete Inspection | No Violations Noted | |
1596528 | Primary Facility | 01/30/2007 | Routine/Complete Inspection | No Violations Noted | |
1598422 | Primary Facility | 02/06/2007 | Routine/Complete Inspection | No Violations Noted | |
1601292 | Primary Facility | 02/20/2007 | Routine/Complete Inspection | No Violations Noted | |
1605032 | Primary Facility | 03/05/2007 | Routine/Complete Inspection | No Violations Noted | |
1609395 | Primary Facility | 03/20/2007 | Routine/Complete Inspection | No Violations Noted | |
1613427 | Primary Facility | 04/02/2007 | Routine/Complete Inspection | No Violations Noted | |
1614137 | Primary Facility | 04/09/2007 | Routine/Complete Inspection | No Violations Noted | |
1617016 | Primary Facility | 04/17/2007 | Routine/Complete Inspection | No Violations Noted | |
1624706 | Primary Facility | 05/22/2007 | Routine/Complete Inspection | No Violations Noted | |
1637504 | Primary Facility | 07/12/2007 | Routine/Complete Inspection | No Violations Noted | |
1644481 | Primary Facility | 08/15/2007 | Routine/Complete Inspection | No Violations Noted | |
1662897 | Primary Facility | 10/29/2007 | Routine/Complete Inspection | No Violations Noted | |
1673500 | Primary Facility | 12/14/2007 | Routine/Complete Inspection | No Violations Noted | |
1688413 | Primary Facility | 02/29/2008 | Routine/Complete Inspection | No Violations Noted | |
1699505 | Primary Facility | 04/15/2008 | Routine/Complete Inspection | No Violations Noted | |
1701774 | Primary Facility | 04/23/2008 | Routine/Complete Inspection | No Violations Noted | |
1705337 | Primary Facility | 05/08/2008 | Routine/Complete Inspection | No Violations Noted | |
1709651 | Primary Facility | 05/28/2008 | Routine/Complete Inspection | No Violations Noted | |
1723674 | Primary Facility | 07/22/2008 | Routine/Complete Inspection | No Violations Noted | |
1750442 | Primary Facility | 11/12/2008 | Routine/Complete Inspection | No Violations Noted | |
1842078 | Primary Facility | 11/03/2009 | Routine/Complete Inspection | No Violations Noted | |
1920835 | Primary Facility | 10/13/2010 | Routine/Complete Inspection | No Violations Noted | |
2024532 | Primary Facility | 11/03/2011 | Routine/Complete Inspection | No Violations Noted | |
2123496 | Primary Facility | 11/14/2012 | Routine/Complete Inspection | No Violations Noted | |
2214669 | Primary Facility | 10/10/2013 | Routine/Complete Inspection | No Violations Noted | |
2323609 | Primary Facility | 10/29/2014 | Routine/Complete Inspection | No Violations Noted | |
2416324 | Primary Facility | 10/16/2015 | Routine/Complete Inspection | No Violations Noted | |
2536178 | Primary Facility | 2016-11-03 | Routine/Complete Inspection | No Violations Noted | |
2643456 | Primary Facility | 2017-09-19 | Routine/Complete Inspection | No Violations Noted | |
2649096 | Primary Facility | 2017-10-18 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig on location for plugging. WL Running in hole to tag TOC after setting ~1000' cement plug on top of bridge plug in 5 1/2". TOC will be estimated at 2500'. TOC on the backside at 3100'. 5 1/2" is dead, minor venting on annulus. They'll pull 5 1/2"' and isolate casing stub w/ cmt plug, gel uphole to shoe plug and fill remainder of well with gravel. No obvious issues observed. |
2651898 | Primary Facility | 2017-10-25 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a recently plugged well. Rig has pulled off location following plug and abandonment. The well is buried and there is a candycane vent monument installed on the well. I checked the vent for gas. No gas was detected with an altair 5x gas meter. No gas was detected at ground level around the event. No obvious issues were observed. |
2652401 | Primary Facility | 2017-10-26 | Administrative/File Review | No Violations Noted | October 26, 2017: Certificate of Well Plugging for the Hoyt 2 (117-00034) has been received, reviewed, signed, and sent to file. |
2713759 | Primary Facility | 2018-03-29 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged vertical well was conducted March 29, 2018. At the time of inspection, there was a 2" candy cane vent pipe installed on top of the plugged well. There was no visual or audible flow coming from the vent. No gas was detected with an Altair 5x gas meter at the opening in the 2" vent pipe. Combustible gas was detected near ground level next to the vent. I contacted the operator who plugged the well to inform them of my findings. The source of the gas is unknown, and the operator is planning to investigate by digging out the cellar to determine the cause of the venting outside the vent pipe. |
2715332 | Primary Facility | 2018-04-06 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged, deep vertical well was conducted April 6, 2018. At the time of inspection; the plugged well monument consists of a 2" candy cane vent and marker plate. No flow was seen coming from inside the vent pipe. A trace of gas was detected with an Altair 5x gas meter inside the vent. The 2" vent pipe is installed in or on the 8 5/8" casing which is buried and not observable at the time. There was small, persistent bubbling observed in standing water in the immediate area outside the 2" vent pipe. The proximity of the bubbling to the vent pipe and comparable venting inside and outside the vent would seemingly indicate the bubbles are coming from inside the 8 5/8" casing, which may not be made up to the vent properly. This is not conclusive since the casing cannot be seen, and the operator plans to investigate further. |
2726687 | Primary Facility | 2018-05-03 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this deep, vertical, plugged well was conducted May 4th, 2018. At the time of inspection, the well has a 2" candy cane vent pipe with marker erected as a plugged well monument. No gas was detected at ground level outside of the vent pipe where gas was previously detected. The operator has properly made up the vent pipe to casing below ground level, and now the wellbore is being vented entirely out of the vent pipe and no longer leaking at the connection where the casing is made up to the vent. No pressure build up was felt at the mouth of the vent. A trace of gas was detected, and audible bubbling was heard coming from inside the vent. |
2780973 | Primary Facility | 2018-09-25 | Routine/Complete Inspection | No Violations Noted | Date: 9/25/2018
CASING PSI: 0 MAX ALLOWABLE PSI: 1,680 VENT: 1. 21 scf/day 2. scf/day 3. scf/day
VENT: 1. 0.4¿ H2O on 1/8th¿ plate 2. ¿ H2O on 1/8th¿ plate 3. ¿ H2O on 1/8th¿ plate
COMMENTS:
|
2790684 | Primary Facility | 2018-10-17 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine inspection of this plugged deep vertical well was conducted 10/18/2018, approximately one year after final plug and abandonment. There is a 2" candy cane vent pipe installed as a plugged well monument. There were no open holes, discharges, or visible venting observed. No obvious issues were observed. |
2840861 | Primary Facility | 2019-02-14 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | A routine, post-plugging, follow-up inspection of this plugged storage well was conducted February 14, 2019. At the time of inspection, the well has a 2" candy cane vent with marker plate erected as a plugged well monument. No visible venting was observed. Audible venting could be heard coming from inside the vent when standing close to it. No pressure could be felt at the vent. A field reading with an Altair 5x gas meter gave unsustained readings of ~0-60 LEL at the mouth of the vent and diminished to 0 LEL at 1" from the mouth of the vent. The location was snow-covered. No active discharge was observed. Spots of discoloration were observed in the snow surrounding the vent. The snow beneath the spots of discoloration appeared clean. |
682412 | Primary Facility | 1988-10-28 | Routine/Complete Inspection | No Violations Noted | |
682413 | Primary Facility | 1989-03-17 | Routine/Complete Inspection | No Violations Noted | |
682414 | Primary Facility | 1989-10-03 | Routine/Complete Inspection | No Violations Noted | |
683195 | Primary Facility | 1990-11-08 | Routine/Complete Inspection | No Violations Noted | |
684100 | Primary Facility | 1991-10-15 | Routine/Complete Inspection | No Violations Noted | |
684692 | Primary Facility | 1992-11-17 | Routine/Complete Inspection | No Violations Noted | |
685191 | Primary Facility | 1993-10-19 | Routine/Complete Inspection | No Violations Noted | |
686076 | Primary Facility | 1994-10-25 | Routine/Complete Inspection | No Violations Noted | |
686910 | Primary Facility | 10/23/1995 | Routine/Complete Inspection | No Violations Noted | |
687842 | Primary Facility | 10/24/1996 | Routine/Complete Inspection | No Violations Noted | |
688427 | Primary Facility | 10/21/1997 | Routine/Complete Inspection | No Violations Noted | |
688512 | Primary Facility | 10/21/1997 | Routine/Complete Inspection | No Violations Noted | |
689388 | Primary Facility | 11/17/1998 | Routine/Complete Inspection | No Violations Noted | |
895951 | Primary Facility | 11/15/1999 | Routine/Complete Inspection | No Violations Noted | |
973376 | Primary Facility | 10/12/2000 | Routine/Complete Inspection | No Violations Noted |