Well Details

Well ID: 37-117-20374
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Ward Township
Operator Name: REPSOL OIL & GAS USA LLC
Well Pad ID: 148195
Farm/Lease Name: DCNR 587 02 008 06
License Status: Active
Spud Date: 05/05/2010
Permit Date: 9/2/2009
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.675319
Longitude: -76.978417

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2009 0.00 0.00 0.00
2010 REPSOL OIL & GAS USA LLC 0.00 0 0.00 0 0.00 0
2011 REPSOL OIL & GAS USA LLC 1,249,652.00 300 0.00 0 0.00 0
2012 REPSOL OIL & GAS USA LLC 1,006,330.20 362 0.00 0 0.00 0
2013 REPSOL OIL & GAS USA LLC 620,151.30 343 0.00 0 0.00 0
2014 REPSOL OIL & GAS USA LLC 475,190.10 360 0.00 0 0.00 0
2015 REPSOL OIL & GAS USA LLC 346,624.70 362 0.00 0 0.00 0
2016 REPSOL OIL & GAS USA LLC 274,416.00 364 0.00 0 0.00 0
2017 REPSOL OIL & GAS USA LLC 197,256.50 323 0.00 0 0.00 0
2018 REPSOL OIL & GAS USA LLC 179,925.70 350 0.00 0 0.00 0
2019 REPSOL OIL & GAS USA LLC 42,078.80 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-2 Drilling Fluid Waste (in Barrels) 394.80 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2010-2 Produced Fluid (in Barrels) 354.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2011-1 Drill Cuttings (in Tons) 2.00 Tons LANDFILL 8-0728-0004/013
2011-1 Drill Cuttings (in Tons) 27.00 Tons LANDFILL NY # 02S17
2011-1 Drill Cuttings (in Tons) 3.00 Tons LANDFILL NY31346244
2011-1 Fracing Fluid Waste (in Barrels) 1,390.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2011-1 Fracturing Fluid Waste (in Tons) 25.00 Tons LANDFILL 100361
2011-2 Produced Fluid (in Barrels) 984.21 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2011-2 Produced Fluid (in Barrels) 303.11 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2011-2 Produced Fluid (in Barrels) 69.16 Bbl REUSE OTHER THAN ROAD SPREADING
2012-1 Produced Fluid (in Barrels) 68.56 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-1 Produced Fluid (in Barrels) 28.81 Bbl INJECTION DISPOSAL WELL 34-133-24189
2012-1 Produced Fluid (in Barrels) 682.75 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 121.48 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-2 Produced Fluid (in Barrels) 61.44 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012-2 Produced Fluid (in Barrels) 240.72 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Produced Fluid (in Barrels) 35.88 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013-1 Produced Fluid (in Barrels) 103.50 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 27.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013-2 Produced Fluid (in Barrels) 297.70 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 30.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-1 Produced Fluid (in Barrels) 310.07 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 226.98 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 127.96 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 98.72 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 24.68 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-2 Produced Fluid (in Barrels) 181.40 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 162.35 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 169.94 Bbl REUSE OTHER THAN ROAD SPREADING
2017-02 Produced Fluid (in Barrels) RWC 802 51.33 Bbl REUSE (AT WELL PAD)
2017-03 Produced Fluid (in Barrels) RWC 802 25.13 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 24.67 Bbl REUSE (AT WELL PAD)
2017-06 Produced Fluid (in Barrels) RWC 802 62.53 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 27.92 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 66.35 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 23.02 Bbl REUSE (AT WELL PAD)
2018-03 Produced Fluid (in Barrels) RWC 802 26.28 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-04 Produced Fluid (in Barrels) RWC 802 24.47 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 51.49 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 23.84 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 22.79 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 28.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-01 Produced Fluid (in Barrels) RWC 802 24.96 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 22.84 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-03 Produced Fluid (in Barrels) RWC 802 48.26 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1900713 Primary Facility 07/21/2010 Drilling/Alteration No Violations Noted
1902116 Primary Facility 07/13/2010 Drilling/Alteration No Violations Noted
1943873 Primary Facility 01/18/2011 Compliance Evaluation No Violations Noted Well blow out on 5H, causing frac fluid release. 6H has been completed.
2094772 Primary Facility 08/23/2012 Routine/Complete Inspection No Violations Noted
2297688 Primary Facility 06/27/2014 Routine/Complete Inspection No Violations Noted
2324193 Primary Facility 11/20/2014 Site Restoration No Violations Noted Recommend approval of NOT. 4 Marcellus gas wells in production.
2711656 Primary Facility 2018-03-28 Routine/Partial Inspection No Violations Noted I got electrical conductivity readings (EC) with an Oakton PCSTestr 35. A puddle on the pad returned a 0.13 mS/cm today. Air temp 47F. JLP
2834696 Primary Facility 2019-02-01 Routine/Complete Inspection No Violations Noted I didn't take any electrical conductivity readings because there is no pooled liquid on site (all frozen).

Air temp 14F, sunny JLP

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 11/22/2010 11/22/2010 8221.0 3573108.0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Recycled Produced Water Carrier/Base Fluid - - 100.0 1.8045
2,2-dibromo-3-nitrilopropio namide 10222-01-2 10.0 0.0025
Ammonium chloride 12125-02-9 1.5 0.001
Hydrochloric acid 7647-01-0 15.0 0.115
Petroleum distillate Proprietary 40.0 0.026
Citric Acid 77-92-9 30.0 0.0013
Methanol 67-56-1 40.0 0.001
Polyethylene glycol 25322-68-3 70.0 0.0175
Propargyl alchohol 107-19-7 8.0 0.0002
Acetic acid 64-19-7 50.0 0.0021
Acid, FEAC-20, LAI-20, FR-8, LSI-21, Bio-Clear 5000 TRICAN Acid, Iron Control Agent, Corrosion Inhibitor, Friction Reducer, Scale Inhibitor, Biocide None None
Sand (Proppant) Proppant - - 100.0 12.6077
Fresh Water Carrier/Base Fluid - - 100.0 84.68