X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-20506

Well Details

Well ID: 37-117-20506
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Charleston Township
Operator Name: SWEPI LP
Well Pad ID: 149014
Farm/Lease Name: PARTHEMER 284 2H
License Status: Active
Spud Date: 03/05/2010
Permit Date: 12/17/2009
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.788014
Longitude: -77.215237

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EAST RESOURCES MGMT LLC 240,761.00 77 0.00 0 0.00 0
2011 SWEPI LP 706,560.21 365 0.00 0 0.00 0
2012 SWEPI LP 405,351.88 366 0.00 0 0.00 0
2013 SWEPI LP 326,460.43 348 0.00 0 0.00 0
2014 SWEPI LP 255,994.52 355 0.00 0 0.00 0
2015 SWEPI LP 182,143.12 281 0.00 0 0.00 0
2016 SWEPI LP 158,056.10 302 0.00 0 0.00 0
2017 SWEPI LP 121,722.84 265 0.00 0 0.00 0
2018 SWEPI LP 113,868.25 277 0.00 0 0.00 0
2019 SWEPI LP 28,659.19 63 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2010-2 Fracing Fluid Waste (in Barrels) 8,622.25 Bbl REUSE OTHER THAN ROAD SPREADING
2011-1 Fracing Fluid Waste (in Barrels) 3,500.93 Bbl REUSE OTHER THAN ROAD SPREADING
2012-1 Produced Fluid (in Barrels) 1,207.05 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Fracing Fluid Waste (in Barrels) 171.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012-2 Fracing Fluid Waste (in Barrels) 45.24 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2012-2 Fracing Fluid Waste (in Barrels) 16.67 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2012-2 Fracing Fluid Waste (in Barrels) 515.08 Bbl REUSE OTHER THAN ROAD SPREADING
2012-2 Produced Fluid (in Barrels) 203.46 Bbl REUSE OTHER THAN ROAD SPREADING
2013-1 Fracing Fluid Waste (in Barrels) 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-1 Produced Fluid (in Barrels) 50.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2013-1 Produced Fluid (in Barrels) 55.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013-1 Produced Fluid (in Barrels) 1,137.64 Bbl REUSE OTHER THAN ROAD SPREADING
2013-2 Produced Fluid (in Barrels) 676.35 Bbl REUSE OTHER THAN ROAD SPREADING
2014-1 Produced Fluid (in Barrels) 590.57 Bbl REUSE OTHER THAN ROAD SPREADING
2014-2 Produced Fluid (in Barrels) 18.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2014-2 Produced Fluid (in Barrels) 100.02 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014-2 Produced Fluid (in Barrels) 175.42 Bbl REUSE OTHER THAN ROAD SPREADING
2015-1 Produced Fluid (in Barrels) 32.01 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-1 Produced Fluid (in Barrels) 83.35 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015-1 Produced Fluid (in Barrels) 151.69 Bbl REUSE OTHER THAN ROAD SPREADING
2015-2 Produced Fluid (in Barrels) 34.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015-2 Produced Fluid (in Barrels) 33.15 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015-2 Produced Fluid (in Barrels) 252.37 Bbl REUSE OTHER THAN ROAD SPREADING
2016-1 Produced Fluid (in Barrels) RWC 802 236.70 Bbl REUSE OTHER THAN ROAD SPREADING
2016-2 Produced Fluid (in Barrels) RWC 802 183.37 Bbl REUSE OTHER THAN ROAD SPREADING
2017-01 Produced Fluid (in Barrels) RWC 802 16.66 Bbl REUSE (AT WELL PAD)
2017-02 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-03 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2017-04 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-04 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2017-05 Produced Fluid (in Barrels) RWC 802 50.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-06 Produced Fluid (in Barrels) RWC 802 66.66 Bbl REUSE (AT WELL PAD)
2017-07 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2017-08 Produced Fluid (in Barrels) RWC 802 128.50 Bbl REUSE (AT WELL PAD)
2017-09 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-09 Produced Fluid (in Barrels) RWC 802 8.33 Bbl REUSE (AT WELL PAD)
2017-10 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2017-11 Produced Fluid (in Barrels) RWC 802 83.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-12 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2017-12 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2018-01 Produced Fluid (in Barrels) RWC 802 18.33 Bbl REUSE (AT WELL PAD)
2018-02 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-03 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2018-04 Produced Fluid (in Barrels) RWC 802 110.66 Bbl REUSE (AT WELL PAD)
2018-05 Produced Fluid (in Barrels) RWC 802 22.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018-05 Produced Fluid (in Barrels) RWC 802 35.61 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-05 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2018-06 Produced Fluid (in Barrels) RWC 802 100.00 Bbl REUSE (AT WELL PAD)
2018-07 Produced Fluid (in Barrels) RWC 802 37.33 Bbl REUSE (AT WELL PAD)
2018-08 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-08 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2018-09 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-09 Produced Fluid (in Barrels) RWC 802 8.33 Bbl REUSE (AT WELL PAD)
2018-10 Produced Fluid (in Barrels) RWC 802 32.48 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-10 Produced Fluid (in Barrels) RWC 802 33.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-10 Produced Fluid (in Barrels) RWC 802 16.67 Bbl REUSE (AT WELL PAD)
2018-11 Produced Fluid (in Barrels) RWC 802 15.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-11 Produced Fluid (in Barrels) RWC 802 19.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-12 Produced Fluid (in Barrels) RWC 802 66.66 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022
2018-12 Produced Fluid (in Barrels) RWC 802 25.00 Bbl REUSE (AT WELL PAD)
2019-01 Produced Fluid (in Barrels) RWC 802 33.33 Bbl REUSE (AT WELL PAD)
2019-02 Produced Fluid (in Barrels) RWC 802 28.67 Bbl REUSE (AT WELL PAD)
2019-03 Produced Fluid (in Barrels) RWC 802 30.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019-03 Produced Fluid (in Barrels) RWC 802 16.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC022

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1947426 Primary Facility 02/02/2011 Compliance Evaluation Violation(s) Noted Flowback release into ditch on site
1967621 Primary Facility 03/05/2011 Follow-up Inspection No Violations Noted to close flowback spill violations
2145198 Primary Facility 02/26/2013 Routine/Complete Inspection No Violations Noted
2235099 Primary Facility 12/30/2013 Routine/Complete Inspection No Violations Noted
2398177 Primary Facility 08/11/2015 Routine/Complete Inspection No Violations Noted
2443775 Primary Facility 2016-01-27 Routine/Complete Inspection No Violations Noted
2475772 Primary Facility 2016-04-14 Routine/Partial Inspection No Violations Noted Partial inspection. Well site was restored in October-November 2015. Post Construction Stormwater Management (PCSM) BMPs have been installed. Site is temporarily stabilized and silt sock remains in place. TLT
2511117 Primary Facility 2016-08-16 Site Restoration No Violations Noted Restoration inspection. DEP received the Well Site Restoration Reports on 6/29/16 for the 1H - 6H wells. Site is restored and post construction stormwater management BMPs have been installed. Site is permanently stabilized with exception to Infiltration Berms 1 & 2. Restoration Reports were reviewed and acknowledged on 8/16/16. TLT
2522774 Primary Facility 2016-09-27 Routine/Complete Inspection No Violations Noted
2590863 Primary Facility 2017-05-05 Routine/Partial Inspection No Violations Noted A compressor station is on this well pad.

EC readings w/ an Oakton PCSTestr 35 in mS/cm: ditch--0.18, production tanks--0.19 & 2.0, near well heads--0.12. 6 separators and 5 chemical injection units on site.

2626596 Primary Facility 2017-08-09 Site Restoration No Violations Noted EC readings w Oakton PCSTestr 35 (mS/cm): pad--0.97, containment--0.64 & 1.2.
2684657 Primary Facility 2018-01-22 Routine/Complete Inspection No Violations Noted Chilly/raining at time of inspection.
2695430 Primary Facility 2018-02-16 Routine/Partial Inspection No Violations Noted SWEPI 's inspection logbook is in a mailbox near the site ID sign; last inspection listed on February 3, 2018. Electrical conductivity (EC) readings taken with an Oakton PCSTestr 35. Air temp 36F. JLP
2826276 Primary Facility 2019-01-14 Routine/Complete Inspection No Violations Noted The DEP conducted a routine inspection of SWEPI's Parthemer 284 Well Pad in Charleston Twp, Tioga County on 1/14/2019 at 1040 hours. The inspection was conducted to assess site conditions. The weather was sunny and 21 degrees.

There are currently 6 wells onsite capable of producing with 6 production tanks. One well appears to be flowing back and a vertical separator and frac tank are installed on it. The site is well vegetated and remains stabilized. No erosional issues were observed today and all fluids on pad surface were frozen solid.

No violations noted today, I departed the site at 1105.

2839228 Primary Facility 2019-02-13 Routine/Complete Inspection No Violations Noted Cold snowy/windy at time of inspection

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1947426 604073 02/02/2011 03/05/2011 401CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety
1947426 604074 02/02/2011 03/05/2011 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
1947426 604075 02/02/2011 03/05/2011 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative

For data sources see[6]

References