{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.619233,"lon":-76.935878,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Union Township | |
Operator Name: ROCKDALE MARCELLUS LLC | |
Well Pad ID: 148892 | |
Farm/Lease Name: MILLER E 116E 6H | |
License Status: Active | |
Spud Date: 05/03/2012 | |
Permit Date: 4/23/2012 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 41.619233 | |
Longitude: -76.935878 |
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 707,960.68 | 169 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 761,536.80 | 336 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 522,941.64 | 338 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 422,030.31 | 365 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 272,940.58 | 326 | 0.00 | 0 | 0.00 | 0 |
2018 | ROCKDALE MARCELLUS LLC | 186,725.83 | 304 | 0.00 | 0 | 0.00 | 0 |
2019 | ROCKDALE MARCELLUS LLC | 36,577.00 | 59 | 0.00 | 0 | 0.00 | 0 |
For data sources see[4]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-2 | Drill Cuttings (in Tons) | 45.95 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-2 | Drill Cuttings (in Tons) | 2,158.40 Tons | LANDFILL | 301358 |
2012-2 | Drilling Fluid Waste (in Barrels) | 93.49 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-2 | Fracing Fluid Waste (in Barrels) | 138.99 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-2 | Fracing Fluid Waste (in Barrels) | 27.98 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2012-2 | Fracing Fluid Waste (in Barrels) | 147.92 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012-2 | Produced Fluid (in Barrels) | 22.62 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012-2 | Produced Fluid (in Barrels) | 37.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Drill Cuttings (in Tons) | 142.33 Tons | LANDFILL | 301358 |
2013-1 | Drilling Fluid Waste (in Barrels) | 64.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-1 | Drilling Fluid Waste (in Barrels) | 7.43 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-1 | Drilling Fluid Waste (in Barrels) | 13.39 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Fracing Fluid Waste (in Barrels) | 244.85 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-1 | Fracing Fluid Waste (in Barrels) | 4.29 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-1 | Fracing Fluid Waste (in Barrels) | 2.78 Bbl | RESIDUAL WASTE TRANSFER FACILITY | PAD987266749 |
2013-1 | Fracing Fluid Waste (in Barrels) | 3,488.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-1 | Produced Fluid (in Barrels) | 48.16 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-1 | Spent Lubricant (in Barrels) | 3.75 Bbl | RESIDUAL WASTE TRANSFER FACILITY | PAD987266749 |
2013-2 | Fracing Fluid Waste (in Barrels) | 110.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013-2 | Fracing Fluid Waste (in Barrels) | 0.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC006 |
2013-2 | Fracing Fluid Waste (in Barrels) | 1.07 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2013-2 | Fracing Fluid Waste (in Barrels) | 8,198.53 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-2 | Produced Fluid (in Barrels) | 3,411.81 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Fracing Fluid Waste (in Barrels) | 12.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-1 | Produced Fluid (in Barrels) | 13.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2014-1 | Produced Fluid (in Barrels) | 132.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014-1 | Produced Fluid (in Barrels) | 1,755.85 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-2 | Produced Fluid (in Barrels) | 822.45 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014-2 | Produced Fluid (in Barrels) | 3,076.51 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Fracing Fluid Waste (in Barrels) | 10.62 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-1 | Produced Fluid (in Barrels) | 12.79 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015-1 | Produced Fluid (in Barrels) | 25.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC011 |
2015-1 | Produced Fluid (in Barrels) | 291.07 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-1 | Produced Fluid (in Barrels) | 806.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Fracing Fluid Waste (in Barrels) | 50.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-2 | Produced Fluid (in Barrels) | 1,207.55 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015-2 | Produced Fluid (in Barrels) | 1,153.53 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 300.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016-1 | Produced Fluid (in Barrels) RWC 802 | 934.92 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 102.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016-2 | Produced Fluid (in Barrels) RWC 802 | 1,104.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-2 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 0.10 Tons | LANDFILL | 301358 |
2016-2 | Synthetic Liner Materials (in Tons) RWC 806 | 0.12 Tons | LANDFILL | 301358 |
2017-01 | Produced Fluid (in Barrels) RWC 802 | 120.00 Bbl | REUSE (AT WELL PAD) | |
2017-02 | Produced Fluid (in Barrels) RWC 802 | 114.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 37.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-03 | Produced Fluid (in Barrels) RWC 802 | 159.99 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Produced Fluid (in Barrels) RWC 802 | 389.98 Bbl | REUSE (AT WELL PAD) | |
2017-04 | Waste Water Treatment Sludge (in Tons) RWC 804 | 1.13 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-05 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-06 | Produced Fluid (in Barrels) RWC 802 | 222.00 Bbl | REUSE (AT WELL PAD) | |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 21.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-07 | Produced Fluid (in Barrels) RWC 802 | 40.00 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 20.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017-08 | Produced Fluid (in Barrels) RWC 802 | 210.20 Bbl | REUSE (AT WELL PAD) | |
2017-08 | Waste Water Treatment Sludge (in Tons) RWC 804 | 2.26 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 14.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017-09 | Produced Fluid (in Barrels) RWC 802 | 174.40 Bbl | REUSE (AT WELL PAD) | |
2017-09 | Synthetic Liner Materials (in Tons) RWC 806 | 0.54 Tons | LANDFILL | 301358 |
2017-09 | Waste Water Treatment Sludge (in Tons) RWC 804 | 1.13 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017-10 | Produced Fluid (in Barrels) RWC 802 | 100.00 Bbl | REUSE (AT WELL PAD) | |
2018-02 | Produced Fluid (in Barrels) RWC 802 | 43.61 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 42.95 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018-03 | Produced Fluid (in Barrels) RWC 802 | 88.00 Bbl | REUSE (AT WELL PAD) | |
2018-04 | Produced Fluid (in Barrels) RWC 802 | 242.00 Bbl | REUSE (AT WELL PAD) | |
2018-05 | Produced Fluid (in Barrels) RWC 802 | 300.40 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Barrels) RWC 802 | 132.00 Bbl | REUSE (AT WELL PAD) | |
2018-06 | Produced Fluid (in Tons) RWC 802 | 0.65 Tons | LANDFILL | 301358 |
2018-06 | Synthetic Liner Materials (in Tons) RWC 806 | 1.17 Tons | LANDFILL | 301358 |
2018-07 | Produced Fluid (in Barrels) RWC 802 | 44.00 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Produced Fluid (in Barrels) RWC 802 | 78.00 Bbl | REUSE (AT WELL PAD) | |
2018-08 | Synthetic Liner Materials (in Tons) RWC 806 | 0.66 Tons | LANDFILL | 301358 |
2018-09 | Produced Fluid (in Barrels) RWC 802 | 24.00 Bbl | REUSE (AT WELL PAD) | |
2018-10 | Produced Fluid (in Barrels) RWC 802 | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018-11 | Produced Fluid (in Barrels) RWC 802 | 66.00 Bbl | REUSE (AT WELL PAD) | |
2018-12 | Produced Fluid (in Barrels) RWC 802 | 20.00 Bbl | REUSE (AT WELL PAD) | |
2019-01 | Synthetic Liner Materials (in Tons) RWC 806 | 1.74 Tons | LANDFILL | 301358 |
2019-01 | Waste Water Treatment Sludge (in Tons) RWC 804 | 4.38 Tons | LANDFILL | 301358 |
2019-02 | Produced Fluid (in Barrels) RWC 802 | 32.86 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Other Oil & Gas Wastes (in Barrels) RWC 899 | 102.60 Bbl | REUSE (AT WELL PAD) | |
2019-03 | Produced Fluid (in Barrels) RWC 802 | 34.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[5]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2123729 | Primary Facility | 12/13/2012 | Routine/Complete Inspection | No Violations Noted | |
2135746 | Primary Facility | 02/01/2013 | Routine/Complete Inspection | No Violations Noted | |
2137099 | Primary Facility | 02/04/2013 | Routine/Complete Inspection | No Violations Noted | 63 gallon (reported) of produced water spilled to the pad not been completely cleaned up. 2H cited |
2139972 | Primary Facility | 02/12/2013 | Routine/Complete Inspection | No Violations Noted | |
2141503 | Primary Facility | 02/19/2013 | Routine/Complete Inspection | No Violations Noted | previous violations (from a brine spill) 2/4/13 closed. No Vio |
2165971 | Primary Facility | 05/10/2013 | Routine/Partial Inspection | No Violations Noted | final day of fracking. 3.5-4.5 mS/cm on pads |
2170239 | Primary Facility | 05/28/2013 | Routine/Complete Inspection | No Violations Noted | |
2197044 | Primary Facility | 08/19/2013 | Compliance Evaluation | No Violations Noted | 100 gal antifreeze spill reported |
2228716 | Primary Facility | 12/11/2013 | Routine/Complete Inspection | No Violations Noted | |
2431319 | Primary Facility | 12/08/2015 | Site Restoration | No Violations Noted | |
2433283 | Primary Facility | 12/16/2015 | Routine/Complete Inspection | No Violations Noted | |
2545969 | Primary Facility | 2016-12-19 | Routine/Complete Inspection | No Violations Noted | |
2555037 | Primary Facility | 2017-01-25 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions. No Shell Representatives were present.
Approximately 4 inches of snow cover on site. Electrical conductivity of puddles on the pad surface ranged from 325 to 570 uS/cm. Due to snow cover, the vegetative cover on iste was not visible. No evidence of accelerated erosion or sedimentation was observed. No violations were cited during this inspection |
2853544 | Primary Facility | 2019-03-13 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess overall site conditions. Seven wells are staged for production. The wells have well tags which say Shell Appalachia instead of Rockdale. The Department recommends replacing the well tags. Some bubbling was observed coming from a green pipe attached to the well head of the 5H well.
Seven GPUs are present and appear to be in good condition overall. Two steel double-walled produced water tanks are present, labeled, and are in good condition. One white plastic produced water tank is present within steel containment with plastic lining. A methanol tote was also present within the containment. Two infiltration basins are present to the west of the pad. Significant accelerated erosion is present downstream of the outlet pipe on the northwest infiltration basin. No other E&S issues noted. No violations noted. |
2856252 | Primary Facility | 2019-03-14 | Routine/Complete Inspection | No Violations Noted | Well was in production. Well had digital pressure monitoring equipment that had no read out. Well had 3 annulus vents plumbed to surface, 2', 1' and 3/4'. 100% LEL and 25% methane was detected on the 2' vent at time of inspection. 0% combustable gas was detected on the other 2 vents or in any area around the well at time of inspection. No violations noted at time of inspection. |
For data sources see[6]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 04/13/2013 | 04/28/2013 | 1 | 6,386,270.0 | 345744 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | EDTA-ACID | Univar | Iron Control | Ethylenediaminetetraacetic acid | 60-00-4 | 99 | 0.00326585 | 1966 |
Water | 7732-18-5 | 1 | 0.00003322 | 20 | ||||
Plexgel 907 | Chemplex, L.C. | Gellant | Guar Gum | 9000-30-0 | 100 | 0.0162096 | 9758 | |
Petro-Flo | Bio-Cide International, Inc | Biocide | Sodium Chloride | 7647-14-5 | 1 | 0.000433564 | 261 | |
Sodium Chlorite | 7758-19-2 | 8.35 | 0.00362134 | 2180 | ||||
Sodium Carbonate | 497-19-8 | 2 | 0.000867127 | 522 | ||||
Sodium Hydroxide | 1310-73-2 | 1 | 0.000433564 | 261 | ||||
15% Hydrochloric Acid | Reagent | Scale Dissolver | 36% Hydrochloric Acid | 7647-01-0 | 15 | 0.0603119 | 36307 | |
Water | 7732-18-5 | 85 | 0.341766 | 205739 | ||||
I-22 | Nalco | Corrosion Inhibitor | Quaternary ammonium compound | Proprietary | 30 | 0.000122926 | 74 | |
Oxyalkylated Fatty Acid Derivative | Proprietary | 30 | 0.000122926 | 74 | ||||
Isopropanol | 67-63-0 | 10 | 0.00004153 | 25 | ||||
Cyclic alkanes | Proprietary | 5 | 0.00001993 | 12 | ||||
Aromatic aldehyde | Proprietary | 30 | 0.000122926 | 74 | ||||
2-Mercaptoethyl Alcohol | 60-24-2 | 5 | 0.00001993 | 12 | ||||
Formic Acid | 64-18-6 | 60 | 0.000244191 | 147 | ||||
Quaternary ammonium compound | Proprietary | 5 | 0.00001993 | 12 | ||||
Methanol | 67-56-1 | 5 | 0.00001993 | 12 | ||||
Water | Operator | Base Carrier Fluid | Water | 7732-18-5 | 100 | 88.476 | 53,261,500.0 | |
Plexgel Breaker 10L | Chemplex, L.C. | Breaker | No Hazardous Ingredients | Proprietary | 100 | 0.000137877 | 83 | |
MSI-7 | National Petrochem | Scale Inhibitor | Hydrogen Chloride | 7647-01-0 | 100 | 0.00890383 | 5360 | |
FE-4 | Chemplex, L.C. | Iron Control Additive | Citric Acid Anhydrous | 77-92-9 | 55 | 0.000730912 | 440 | |
Water | 7732-18-5 | 55 | 0.000730912 | 440 | ||||
Sand | Operator | Proppant | Silicon Dioxide | 14808-60-7 | 100 | 10.9555 | 6,595,060.0 | |
FR900 | Nalco | Friction Reducer | Proprietary | Proprietary | 100 | 0.0927992 | 55864 |
For data sources see[7]