X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-081-20937

Well Details

Well ID: 37-081-20937
Loading map...
Country: United States
State: Pennsylvania
County: Lycoming
Municipality: Gamble Township
Operator Name: ARD OPR LLC
Well Pad ID: 148400
Farm/Lease Name: GEORGE E HAGEMEYER A 2H
License Status: Active
Spud Date: 05/01/2012
Permit Date: 4/20/2012
Unconventional Well: Y
Configuration: Horizontal Well
Latitude: 41.419794
Longitude: -76.951181

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 ANADARKO E&P ONSHORE LLC 0.00 0 0.00 0 0.00 0
2013 ANADARKO E&P ONSHORE LLC 754,826.00 160 0.00 0 0.00 0
2014 ANADARKO E&P ONSHORE LLC 814,949.00 364 0.00 0 0.00 0
2015 ANADARKO E&P ONSHORE LLC 439,176.00 361 0.00 0 0.00 0
2016 ANADARKO E&P ONSHORE LLC 252,866.00 366 0.00 0 0.00 0
2017 ANADARKO E&P ONSHORE LLC 155,177.80 337 0.00 0 0.00 0
2018 ARD OPR LLC 142,922.85 316 0.00 0 0.00 0
2019 ARD OPR LLC 36,008.17 90 0.00 0 0.00 0

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2012-S01 Drill Cuttings (in Tons) 31.57 Tons LANDFILL 100955
2012-S02 Drill Cuttings (in Tons) 794.83 Tons LANDFILL 301626
2013-S02 Produced Fluid (in Barrels) 7,382.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S01 Produced Fluid (in Barrels) 2,433.71 Bbl REUSE OTHER THAN ROAD SPREADING
2014-S02 Produced Fluid (in Barrels) 810.21 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S01 Produced Fluid (in Barrels) 581.60 Bbl REUSE OTHER THAN ROAD SPREADING
2015-S02 Produced Fluid (in Barrels) 440.71 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015-S02 Produced Fluid (in Barrels) 297.84 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-M09 Produced Fluid (in Barrels) RWC 802 130.54 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016-M10 Produced Fluid (in Barrels) RWC 802 106.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016-M11 Produced Fluid (in Barrels) RWC 802 106.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016-M12 Produced Fluid (in Barrels) RWC 802 59.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2016-M12 Produced Fluid (in Barrels) RWC 802 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016-S01 Produced Fluid (in Barrels) RWC 802 345.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2016-S01 Produced Fluid (in Barrels) RWC 802 238.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-S02 Produced Fluid (in Barrels) RWC 802 69.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2016-S02 Produced Fluid (in Barrels) RWC 802 28.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2017-M01 Produced Fluid (in Barrels) RWC 802 59.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2017-M01 Produced Fluid (in Barrels) RWC 802 30.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M02 Produced Fluid (in Barrels) RWC 802 84.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M03 Produced Fluid (in Barrels) RWC 802 92.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M04 Produced Fluid (in Barrels) RWC 802 89.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M05 Produced Fluid (in Barrels) RWC 802 57.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M05 Produced Fluid (in Barrels) RWC 802 29.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M07 Produced Fluid (in Barrels) RWC 802 68.00 Bbl INJECTION DISPOSAL WELL 34-031-27177
2017-M08 Produced Fluid (in Barrels) RWC 802 88.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M09 Produced Fluid (in Barrels) RWC 802 62.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017-M10 Produced Fluid (in Barrels) RWC 802 71.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017-M12 Produced Fluid (in Barrels) RWC 802 32.26 Bbl REUSE (AT WELL PAD)
2018-M01 Produced Fluid (in Barrels) RWC 802 3.76 Bbl REUSE (AT WELL PAD)
2018-M02 Produced Fluid (in Barrels) RWC 802 5.00 Bbl REUSE (AT WELL PAD)
2018-M03 Produced Fluid (in Barrels) RWC 802 56.00 Bbl REUSE (AT WELL PAD)
2018-M04 Produced Fluid (in Barrels) RWC 802 32.13 Bbl REUSE (AT WELL PAD)
2018-M05 Produced Fluid (in Barrels) RWC 802 6.90 Bbl REUSE (AT WELL PAD)
2018-M06 Produced Fluid (in Barrels) RWC 802 1.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M06 Produced Fluid (in Barrels) RWC 802 1.05 Bbl REUSE (AT WELL PAD)
2018-M07 Produced Fluid (in Barrels) RWC 802 3.30 Bbl REUSE (AT WELL PAD)
2018-M08 Produced Fluid (in Barrels) RWC 802 2.66 Bbl REUSE (AT WELL PAD)
2018-M09 Produced Fluid (in Barrels) RWC 802 1.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M09 Produced Fluid (in Barrels) RWC 802 1.09 Bbl REUSE (AT WELL PAD)
2018-M11 Produced Fluid (in Barrels) RWC 802 0.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2018-M11 Produced Fluid (in Barrels) RWC 802 2.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018-M12 Produced Fluid (in Barrels) RWC 802 1.92 Bbl REUSE (AT WELL PAD)
2019-M01 Produced Fluid (in Barrels) RWC 802 0.56 Bbl REUSE (AT WELL PAD)
2019-M02 Produced Fluid (in Barrels) RWC 802 1.53 Bbl REUSE (AT WELL PAD)
2019-M03 Produced Fluid (in Barrels) RWC 802 0.69 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019-M03 Produced Fluid (in Barrels) RWC 802 1.05 Bbl REUSE (AT WELL PAD)

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2062841 Primary Facility 04/25/2012 Routine/Complete Inspection No Violations Noted
2077409 Primary Facility 06/18/2012 Routine/Complete Inspection No Violations Noted
2085837 Primary Facility 07/23/2012 Routine/Complete Inspection No Violations Noted
2092296 Primary Facility 08/16/2012 Drilling/Alteration No Violations Noted
2098781 Primary Facility 09/10/2012 Routine/Complete Inspection No Violations Noted
2106580 Primary Facility 10/04/2012 Routine/Complete Inspection No Violations Noted
2110496 Primary Facility 10/23/2012 Routine/Complete Inspection No Violations Noted
2153117 Primary Facility 04/02/2013 Routine/Complete Inspection No Violations Noted
2159849 Primary Facility 04/18/2013 Routine/Complete Inspection No Violations Noted
2554589 Primary Facility 2017-01-19 Routine/Complete Inspection No Violations Noted Routine Inspection; 1/19/2017.

I entered the site at 10:30. At the time of the inspection, the George Hagemeyer A 1H (081-20692), 2H (081-20937), 3H (081-20398), 4H (081-20938), 5H (081-20698), and 6H (081-20939). ESX10-081-0038 was amended on 7/17/2015 to address PCSM (Post Construction Stormwater Management) and well site restoration. Currently, the site remains at the originally permitted size and the amended plan has not yet been implemented.

The most recent update to the well site restoration assessment Anadarko provided on 12/22/2016 indicates the PCSM for the site was to be implemented in 2016. The WSRR (Well Site Restoration Report) and 2-year extension were scheduled to be submitted to the Department in 2017. I recommend implementing the permitted plan. No Violations Noted.

2580616 Primary Facility 2017-01-19 Routine/Complete Inspection No Violations Noted
2580763 Primary Facility 2017-03-23 Site Restoration No Violations Noted Notice of Termination Inspection; 3/23/2017.

I entered the site at 14:05. At the time of the inspection, the George Hagemeyer A 1H (081-20692), 2H (081-20937), 3H (081-20398), 4H (081-20938), 5H (081-20698), and 6H (081-20939) were in production. ESX10-081-0038 was amended on 7/17/2015 to address PCSM (Post Construction Stormwater Management) and well site restoration. The PCSM/Site Restoration plan has been implemented and the instrument recorded on the deed. The site is permanently stabilized and is in good condition. While the pad surface has not been reduced in size, the permit modification clarifies the use of the remaining well pad area and has minimized the overall footprint of the site. I recommend the Notice of Termination for this site be approved. I also contacted the operator and requested that the Well Site Restoration Reports be submitted for the wells on this site.

4/6/2017: On 4/6/2017, the operator submitted a Well Site Restoration Report (WSRR) as requested in the 3/23/3017 inspection. T

2847175 Primary Facility 2019-03-04 Routine/Complete Inspection No Violations Noted Five wells staged for production phase. Five each GPUs within containment. One natural gas powered Capstone 65kW turbine on site. Turbine noise output was 69dBs. No leaks detected from production equipment. No violations noted.

For data sources see[6]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 03/30/2013 06/15/2013 7691 2,871,330.0 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Sand (Proppant) Trican Well Service Proppant Quartz 14808-60-7 99 15.3661 4,396,110.0
Hexamethylenetretramine 100-97-0 1 0.155213 44405.2
AI-7NR Trican Well Service Corrosion Inhibitor Prop-2-yn-1-ol 107-19-7 1 0.00002334 6.676
Bio-Clear 5000 Trican Well Service Biocide Polyethylene glycol 25322-68-3 70 0.0336167 9617.45
2,2-dibromo-3-nitrilopropionamide 10222-01-2 10 0.00480238 1373.92
Hydrochloric Acid (7.5%) Trican Well Service Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0455036 13018.2
Bio-Clear 1000 Trican Well Service Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 98 0.00018155 51.94
FEAC-20 Trican Well Service Iron Control Citric Acid 77-92-9 30 0.00165213 472.661
Acetic Acid 64-19-7 50 0.00275355 787.768
FR-15 Trican Well Service Friction Reducer Paraffinic, Naphthenic Solvent 64742-47-8 25 0.01556 4451.6
Proprietary Amide Proprietary 2.5 0.001556 445.16
Water Anadarko Carrier/Base Fluid Water 7732-18-5 100 83.7537 23,961,200.0

For data sources see[7]

References