X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-129-28593

Well Details

Well ID: 37-129-28593
Loading map...
Country: United States
State: Pennsylvania
County: Westmoreland
Municipality: Lower Burrell City
Operator Name: PENNECO OIL CO INC
Well Pad ID:
Farm/Lease Name: SLUSS 7H
License Status: Active
Spud Date: 06/27/2011
Permit Date: 5/26/2011
Unconventional Well: N
Configuration: Deviated Well
Latitude: 40.566833
Longitude: -79.706389

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 PENNECO OIL CO INC 1,583.00 92 2,719.24 92 0.00
2012 PENNECO OIL CO INC 12,187.00 274 5,167.15 274 0.00
2013 PENNECO OIL CO INC 9,237.00 365 2,304.14 365 0.00
2014 PENNECO OIL CO INC 11,376.00 365 1,528.95 365 0.00
2015 PENNECO OIL CO INC 8,927.32 365 1,021.52 212 0.00
2016 PENNECO OIL CO INC 7,966.24 366 546.59 91 0.00
2017 PENNECO OIL CO INC 5,493.00 365 534.31 365 0.00
2018 PENNECO OIL CO INC 7,194.15 365 144.09 30 0.00

For data sources see[4]

Waste Data

Period Waste Type Quantity Disposal Method Waste Facility ID
2011-A00 Drilling Fluid Waste (in Barrels) 770.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011-A00 Drilling Fluid Waste (in Barrels) 240.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011-A00 Fracing Fluid Waste (in Barrels) 80.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2011-A00 Fracing Fluid Waste (in Barrels) 480.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011-A00 Produced Fluid (in Barrels) 160.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012-A00 Produced Fluid (in Barrels) 438.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013-A00 Produced Fluid (in Barrels) 1,335.19 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2014-A00 Produced Fluid (in Barrels) 249.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2016-A00 Produced Fluid (in Barrels) RWC 802 58.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2017-A00 Produced Fluid (in Barrels) RWC 802 80.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2017-A00 Produced Fluid (in Barrels) RWC 802 433.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123SW005

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1986056 Primary Facility 07/01/2011 Drilling/Alteration No Violations Noted US Energy Rig #4 RD20 waiting on cement at time of inspection. Pit lined and freeboard maintained. Inspection conducted w/OGI's D. Catalano and J. Branan.
1986084 Primary Facility 07/06/2011 Drilling/Alteration No Violations Noted US Energy Rig #4 RD20 waiting on bit at time of inspection. 17 1/2" hole at 447'. Cement basket on 13 3/8" mine string to be placed at 392'. Pit lined and freeboard maintained.
1989906 Primary Facility 07/14/2011 Drilling/Alteration No Violations Noted US Energy Rig #4 RD20 tripping out of hole at time of inspection. 7 7/8" hole TD=3175'. Pit lined and freeboard maintained.
1998543 Primary Facility 08/25/2011 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Drill pit located onsite and it had more than the required two feet of lined freeboard. All erosion controls appeared to be functioning properly and no accelerated erosion or sedimentation was observed in relation to the access road or well-site. At the time of the inspection the operator was pumping water up from Pucketa Creek for well stimulation activities. Operator should continue to monitor the site until all development activities are completed.
2031331 Primary Facility 01/04/2012 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Above ground tanks and pumpjack apparatus located onsite and all appeared to be in sound condition. Site had not as of yet been regraded. There was no evidence of accelerated erosion or sedimentation in relation to the access road or well-site. The operator should temporariluy stabilize the site in accordance with 102.22(b) until final site restoration can be completed.
2069607 Primary Facility 05/21/2012 Site Restoration No Violations Noted At the time of inspection the well appears to drilled and equipped for production. The well apparatus, brine tank, brine tank containment, and pump jack located onsite appear to be in sound working condition. The site has recently been regraded, seed and mulch. The Department suggest the Operator continue to monitor the site to ensure the 70% uniform vegetative coverage criteria is met.

For data sources see[6]