X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-111-22673

Well Details

Well ID: 34-111-22673
Loading map...
Country: United States
State: Ohio
County: Monroe
Municipality: Franklin
Operator Name: RACK RIDGE LLC
Well Pad ID:
Farm/Lease Name: FREDRICK
License Status: Final Restoration
License Date: 2015-11-09
Spud Date:
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 39.710324691
Longitude: -81.30666377

For data sources see[1]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 RACK RIDGE LLC 0 17 365
2009 RACK RIDGE LLC 64 0 365
2010 RACK RIDGE LLC 9 0 50
2011 RACK RIDGE LLC 70 5 365
2012 RACK RIDGE LLC 47 0 366
2013 RACK RIDGE LLC 45 0 200
2015 RACK RIDGE LLC 47 0 120

For data sources see[1][2]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 RACK RIDGE LLC Brine 26 365
2009 RACK RIDGE LLC Brine 0 365
2010 RACK RIDGE LLC Brine 0 50
2011 RACK RIDGE LLC Brine 20 365
2012 RACK RIDGE LLC Brine 0 366
2013 RACK RIDGE LLC Brine 0 200
2015 RACK RIDGE LLC Brine 0 120

For data sources see[1][2]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0018092733 2010-08-10 Production Wells No Violations On day of inspection Boyd and I and Bret Farnsworth went in to site. There was 90%vegetation.Well is going to be a swab well.Well is in compliance.NOV is resolved.
0058842242 2014-09-29 Administrative Inspection No Violations Administrative inspection to document the unresolved compliance notice, no contact has been received by Harry Boyd with Rack Ridge concerning the unresolved violation.
0153713132 2009-04-09 Production Wells No Violations
0210532133 2014-06-26 Production Wells No Violations Compliance notice 2001769233 follow up inspection found the production valve in the closed position and the 1.250 flow line cut in half near the well head. The well is still incapable of production in its current state and has a unresolved compliance notice issued on it requiring plugging and abandonment.
1130397897 2015-10-02 Plug / Plug Back No Violations I am onsite to witness the plugging operations. 1.5 tubing was already set at a depth of 1293 by Robert Armstrongs service rig. Cemenco circulated a 15 sack class A plug from 1293 to 993. The service rig pulled the 1.5 tubing out of the well. Jet Wireline Services utilized a collar buster shot at 749 to cut the 3 drill pipe (production casing). Circulation could not be established. The service rig then pulled up to 417 where circulation could be established and circulated cement up to 200. Casing was then pulled up to 200 and cement was circulated to surface.
1255054457 2009-10-08 Production Wells No Violations WELL IS SUPPLIED WITH 3HYDRIL PIPE.WELL MAKES LITTLE GAS.NO DOMESTIC HOOKUP.ID INPLACE.THERE IS 90%+VEGATATION.NO PRODUCTION HAS BEEN TURNED IN TO STATE.
1259001160 2009-11-09 Production Wells Violations Noted On day of inspection found that well was shut in and Rack Ridge has not been filing the production reports to the State. Plug or Produce. Failure to comply may result in bond forfeiture. File production reports with the State.
1281687531 2008-12-05 Production Wells Violations Noted WELL IS SHUT IN AND HAS 3HYDRIL IN IT.WELL IS PERFERATED THROUGH THE DRILL PIPE AND MAKES GAS.WELL NEEDS ID.
1443192647 2015-09-25 Plug / Plug Back No Violations On site inspection to witness the 1,292of 1.5 tubing ran into the well inside the 3 production casing. Company records show JET Wireline Service logged the well on 08-13-2008 with a recorded total depth of 1,273 and top of cement on the annular side of the 3 @ 992.
1444149722 2015-10-06 Administrative Inspection No Violations Compliance notice 2001769233 follow up inspection to document the resolution of the violation. The well was plugged on 10/02/2015.
1796101288 2009-04-09 Production Wells No Violations WELL IS CAPABLE WITH GAS LINE TIED IN TO COMMERCIAL PRODUCTION.WELL HAS 3HYDRILL AND NEEDS SWABBED OUT ONCE A YEAR.WELL IS COMPLIANT.
1863632556 2015-10-06 Plug / Plug Back No Violations I met Robert Armstrong on location and verified the cement stayed at surface so he could cut the casing off and begin the reclamation. The cement top was visible approximately four feet from surface. Mr. Armstrong was instructed to reclaim the site in accordance with 1509.072(B).
1867428980 2014-06-26 Production Wells No Violations I am accompanied by Oil & Gas Inspector Bill Stolarik. My inspection finds the well is shut in and the gas line leading from the well appears to be parted.
1946435807 2015-11-09 Final Restoration No Violations Final Restoration status check inspection found the wells site meets ORC 1509.072. The equipment has been removed and the location reclaimed, the landowner and well owner Harry Boyd will continue to use the roadways to access the property and remaining existing wells.
2001769233 2014-03-26 Production Wells Violations Noted Status check inspection found the following equipment present at the well head-3.500 high drill tubing with a reducing swage down to a 2 valve in the closed position with a 2 flow line present and proper well identification posted. Database records show the reported production to be below the minimum standard of 100 mcf since 2008. Instructions are as follows -plug the said well within 180 days- ODNR contact-Monroe Co inspector Bill Stolarik 740-507-6592.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1259001160 US-OH-106973 2009-11-23 Well shall be plugged
1259001160 US-OH-106974 2009-11-23 Urban - failure to meet tank battery setbacks from mandatory pooled property
1281687531 US-OH-107827 2008-12-08 Failure to legibly identify well
1281687531 US-OH-107828 2008-12-08 Well shall be plugged
2001769233 US-OH-120317 2015-11-23 Well shall be plugged

For data sources see[1]


Well History

Well Status Well Status Date Comment
CO 1981-11-18 2947 REUSSER LYNN & HERMAN GeoDate 11/18/81
Change of Owner 2002-02-26 Operator changed from 2947, REUSSER LYNN & HERMAN to 6283, TENNANT LARRY P & BARBARA J
Change of Owner 2002-07-01 Operator changed from 6283, TENNANT LARRY P & BARBARA J to 7239, BOYD
APP 2015-06-24 Proposed Formations:BEREA, Issued Date:6/24/2015, Expired Date:6/23/2017 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2015-10-06 PERMIT EXPIRED.
Record Last Modified 2017-02-10 PERMIT EXPIRED.
Construction Permit Expires 2017-06-23 PERMIT EXPIRED.

For data sources see[1]

References

  1. 1.0 1.1 1.2 1.3 1.4 "RBDMS". Ohio Department of Natural Resources. 2019-05-07. Retrieved 2019-05-21. 
  2. 2.0 2.1 "Ohio Combined Annual Production Data". Ohio Department of Natural Resources. 2019-05-07. Retrieved 2019-05-21.