If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-029-21520 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.83360296,"lon":-80.87949285,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Columbiana | |
Municipality: Butler Township | |
Operator Name: EVERFLOW EASTERN PTNS L P | |
Well Pad ID: | |
Farm/Lease Name: COPE | |
License Status: Producing | |
License Date: 1990-05-23 | |
Spud Date: 1990-06-01 | |
Spud Drilling Contractor: ADVENT DRLG | |
Final Drill Date: 1990-06-08 | |
Well Total Depth: 6027 ft | |
Configuration: Vertical | |
Latitude: 40.833602960 | |
Longitude: -80.87949285 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1990-05-23 | 3069 MURNANE JOSEPH M GeoDate 5/23/90 |
Oil and Gas | 1990-05-23 | Issued Date 5/23/90 Expired Date 5/23/91 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 06027 Proposed Drill Depth 06027 |
Original Spud | 1990-06-01 | LOG TYPE=BOND FDT=SHALE |
Completed | 1990-06-08 | LOG TYPE=BOND FDT=SHALE |
Reached Total Depth | 1990-06-08 | LOG TYPE=BOND FDT=SHALE |
Completion Report Received | 1990-08-02 | LOG TYPE=BOND FDT=SHALE |
Construction Permit Expires | 1991-05-23 | LOG TYPE=BOND FDT=SHALE |
CO | 1994-02-14 | 213 LOMAK OPERATING CO GeoDate 5/23/90 |
Change of Owner | 2000-06-27 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2009-07-29 | Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 84, EVERFLOW EASTERN PTNS L P |
Record Last Modified | 2017-02-15 | LOG TYPE=BOND FDT=SHALE |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 5795 | 5944 | 0 |
2006-09-11 | 5822 | 5940 | 50 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 3000 Bbl | 60000 | FRAC:WATER/SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000009307 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 1/12/93 INSPECTOR BRETT FARNSWORTH DATE 01/1219/93 DATA FROM OLD VAX INFO | |
0467382279 | 2016-10-25 | Production Wells | No Violations | The purpose for my inspection was to conduct a status check on well # 2-1520. A review of RBDMS indicates the operator is current with reporting production. Lease access is through a wooded clearing that is stable with well-established vegetation. A locked steel gate with correct and legible site identification marks the entrance to the well head and tank battery. The well location is within a clearing that is stable with well-established vegetation. Correct and legible identification is posted on the well head. The 8.625 production casing is above grade and contains a plug in one side port and a nipple and hammer union that is open to atmosphere in the other port. The 4.5 production casing is equipped with a plunger lift assembly. The Demco gate valve is in the closed position. No audible or visual leaks were detected. Production equipment is contained within an earthen dike that is stable and sufficient for containment. Equipment within the dike consists of one (1) horizontal separator and one (1) 100 bbl production tank. The separator was in good repair. No audible or visual leaks were detected. Production valves were in the closed position. The meter house did not contain a current production chart. The production tank remained in good repair. No leaks were detected. The load line and drain valves were closed and contained plugs. The hatch lid was closed. No violations were observed during this inspection. |
For data sources see[9]