If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-005-21791 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.895907147,"lon":-82.15600617,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Ashland | |
Municipality: Perry Township | |
Operator Name: DEEP RESOURCES LLC | |
Well Pad ID: | |
Farm/Lease Name: GLADYS C. MANN | |
License Status: Final Restoration | |
License Date: 2013-10-17 | |
Spud Date: 1976-08-27 | |
Spud Drilling Contractor: SHORTS DRLG | |
Final Drill Date: 1976-09-02 | |
Well Total Depth: 652 ft | |
Configuration: Vertical | |
Latitude: 40.895907147 | |
Longitude: -82.15600617 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1975-04-10 | 133 QUAKER STATE OIL REF CORP GeoDate 4/10/75 |
Enhanced Recovery | 1975-04-10 | Issued Date 4/10/75 Expired Date Acres 0001700 Tool Type CRAF Proposed Formation BEREA Proposed Depth 00000 Proposed Drill Depth 00000 |
Completed | 1976-08-27 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Original Spud | 1976-08-27 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Reached Total Depth | 1976-09-02 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
CO | 1995-10-18 | 182 BELDEN & BLAKE CO GeoDate 4/10/75 |
Annulus Pressure Monitoring Approved | 1998-11-23 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Last Compliance Report | 1999-10-05 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Change of Owner | 2002-02-07 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER |
Change of Owner | 2008-04-24 | Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC |
APP | 2013-05-29 | Proposed Formations:BEREA, Issued Date:5/29/2013, Expired Date:5/29/2015 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:EOR, Proposed Well Class: |
Plugged/Abandoned | 2013-06-20 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Construction Permit Expires | 2015-05-29 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
Record Last Modified | 2017-02-15 | SEC. REC.-CONV. TO INJ. WELL 4-26-75 IP. OIL = 1/2 BBL. CLASS=MBE |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-19 | 570 | 614 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
NITR | 0 | 40 Qts | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | DEEP RESOURCES LLC | 0 | 13 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2007 | DEEP RESOURCES LLC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0040325828 | 2012-12-04 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0043150819 | 2008-03-27 | Enhanced Recovery Project | No Violations | Annulus and injection pressure test. |
0111057061 | 2010-04-06 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0111963044 | 2007-03-30 | Enhanced Recovery Project | Violations Noted | Injection and annulaus pressure test. Pressures are equalized at 350 psi. |
0208962727 | 2006-03-15 | Enhanced Recovery Project | Violations Noted | Re-test annulus and tubing pressures. Nov in compliance. Snow, 29 degrees |
0279559499 | 2010-11-27 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0473608655 | 2011-07-12 | Enhanced Recovery Project | No Violations | inspect well |
0502459913 | 2003-08-07 | Enhanced Recovery Project | No Violations | UNABLE TO GAUGE INJECTION PRESSURE, NEED TO REPLACE WITH VALVE TAP FOR 1/4 OR 1/2 GAUGE |
0503156724 | 2011-10-17 | Enhanced Recovery Project | No Violations | Inspect well. |
0510006879 | 2013-03-04 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. |
0511764643 | 2012-09-11 | Enhanced Recovery Project | No Violations | Inspect Well. Site ok. |
0583280891 | 2005-12-01 | Enhanced Recovery Project | Violations Noted | Injection and annulus pressure test. Pressures have equalized at 350 psi. |
0625117970 | 2004-11-18 | Enhanced Recovery Project | No Violations | Injection pressure test. |
0735082993 | 2011-04-13 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0751620049 | 2006-04-24 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
0763086463 | 2013-04-04 | Enhanced Recovery Project | No Violations | Inspect well for integrity and pressure. Conduct fifteen minute pressure test on well. Test failed. Well shut in. |
0774942903 | 2013-10-17 | Final Restoration | No Violations | All equipment has been removed from the site. The location is finish graded and vegetated. Casing has been cut off. The final restoration is approved. |
0923400769 | 2009-10-07 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1082935222 | 2006-12-29 | Enhanced Recovery Project | No Violations | NOV followup. Ran Mini test on annulus and pressure held at 410psi for 15 minutes. Injection pressure is at 350 psi. |
1116355295 | 2005-05-17 | Enhanced Recovery Project | No Violations | Injection well test. GPS location and update to RBDMS. |
1192038614 | 2007-10-10 | Enhanced Recovery Project | Violations Noted | Injection and annulus pressure test. Pressures are equalized at 330 psi. Suspended well operation at this time. |
1350741638 | 2012-06-04 | Enhanced Recovery Project | No Violations | Inspect Well. Annulus valve was replaced. Box needs repair. |
1371742425 | 2013-06-20 | Plug / Plug Back | No Violations | Request from operator to witness well plugging. The well was plugged with 9 sack grout. |
1376581904 | 2013-08-15 | Final Restoration | No Violations | The site needs to be graded and a pipe rack with 1 inch tubing removed to approve final restoration. Randy at Deep Resources was advised. He stated he would call when work is complete. |
1464663205 | 2013-05-08 | Enhanced Recovery Project | No Violations | Operator pickled and cleaned casing with acid. Run tubing and packer with new rubbers and cage. Pressure test of well did not pass. Significant loss of pressure when tested. Five times a joint of pipe was pulled up, packer set, loaded with water and pressure tested. Each test failed. Tool pusher reported the packer would set down at a depth of 268 feet below grade. Pulled packer up and set at 257 ft. above obstruction. Pressure tested ok at 257. The following day the packer was set and tested at 293 ft., below obstruction. Pressure test failed. Hole in casing about 268 feet. Reviewed old records the original well was drilled 8 to 10 inches from current hole. Due to casing being pushed out of bore hole by shooting with nitroglycerin. Well will be plugged. |
1542833910 | 2008-12-11 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1565115727 | 2007-10-22 | Enhanced Recovery Project | No Violations | Reset packer and tested but pressure equilized. Recommend pulling packer out and inspect. Shut well in until it will test. |
1565488129 | 2006-12-15 | Enhanced Recovery Project | Violations Noted | Injection and annulus pressure test. Pressures are equalized at 350 psi. |
1609952911 | 2012-02-27 | Enhanced Recovery Project | No Violations | Inspect well. Valve on Annulus is broken. |
1722416447 | 2009-04-25 | Enhanced Recovery Project | No Violations | Injection and annulus pressure test. |
1850524506 | 2007-10-30 | Enhanced Recovery Project | No Violations | Mechanical integrity test. Pulled 1 tubing and packer. Replaced packer and circulated inhibitor thru annulus and pressure tested packer and tubing at 350 psi. Drop of 10 psi in 15 minutes. NOV in compliance. Sun, 55 degrees. |
1948417058 | 2004-04-22 | Enhanced Recovery Project | No Violations | Injection pressure test. Could not test tubing pressure due to size of gauge threads. Advised Len Rex to install reducer and test. Report to Tom Tomastik in 30 days. |
1958963302 | 2007-04-03 | Enhanced Recovery Project | No Violations | NOV in compliance. Blew down annulus and pressured up to 320 psi. Pressure held at 320 psi for 15 minutes. 0% decline. Injection pressure is 290 psi. Advised Matt Miller of injection pressure decline. Run mini test April 30, 2007 and report to inspector. |
2018932901 | 2013-05-02 | Enhanced Recovery Project | No Violations | Run packer and tubing into well, 21 joints at 25 feet each with a Butler Larkin 6 inch compression packer with new rubbers. Each individual joint of tubing was pressure tested for leaks. The packer was originally set at 525 feet. Formation gas was leaking past packer and the test was not successful. Operator will install tie downs to set and hold packer. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0111963044 | US-OH-103040 | 2007-03-30 | Failure to conduct or pass mech. integrity test | |
0208962727 | US-OH-121336 | 2005-12-07 | Mechanical failure/contamination | |
0583280891 | US-OH-126548 | 2005-12-07 | Mechanical failure/contamination | |
1192038614 | US-OH-105072 | 2007-10-10 | Failure to conduct or pass mech. integrity test | |
1565488129 | US-OH-115294 | 2006-12-15 | Failure to conduct or pass mech. integrity test |
For data sources see[9]