X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-24407

Well Details

Well ID: 34-121-24407
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Seneca Township
Operator Name: ANTERO RESOURCES CORPORATION
Well Pad ID: 000650
Farm/Lease Name: MILLIGAN UNIT
License Status: Producing
License Date: 2013-09-27
Spud Date: 2013-04-23
Spud Drilling Contractor: PATTERSON DRILLING
Final Drill Date: 2013-08-11
Well Total Depth: 13702 ft
Configuration: Horizontal
Latitude: 39.864039898
Longitude: -81.43098044

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2013-02-15 Proposed Formations:POINT PLEASANT, Issued Date:2/15/2013, Expired Date:2/15/2015 12:00:00 PM, Drilling unit acres:505.549, Proposed Well Type:OG, Proposed Well Class:EDPW
Correction to Well 2013-03-01 CORRECTION TO LEASE NAME.
Reached Total Depth 2013-08-11
Correction to Well 2013-08-16 CHANGE IN PROPOSED TOTAL DEPTH.
Correction to Well 2013-11-01 CHANGE IN SURFACE FOOTAGE FROM AS DRILLED SURVEY PLAT. UNIT SIZE CHANGED TO 513.038 ACRES.
Completion Report Received 2014-01-27
APP 2014-06-20 Proposed Formations:POINT PLEASANT, Issued Date:6/20/2014, Expired Date:6/19/2016 12:00:00 PM, Drilling unit acres:513.038, Proposed Well Type:OG, Proposed Well Class:POOL
Construction Permit Expires 2016-06-19
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2014-01-28 8498 13564 0

For data sources see[3]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 10/07/2013 10/17/2013 7818 6,837,680.0 292680

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WFRA-405 U.S. Well Services, LLC Friction Reducer Water 7732-18-5 40 0.02511 15836
Petroleum Distillates 64742-47-8 22 0.02021 12748
Anionic Polyacrylamide Proprietary 0 0.02511 15836
Crystalline Salt 12125-02-9 5 0.00314 1979.5
Ethoxylated alcohol blend Proprietary 5 0.00314 1979.5
LGC-15 U.S. Well Services, LLC Gelling Agents Surfactant 68439-51-0 3 0.0022 1385.25
Suspending agent (solid) 14808-60-7 3 0.0056 3531.02
Guar Gum 9000-30-0 50 0.0366 23087.5
Petroleum Distillates 64742-47-8 60 0.03466 21865.2
AP One U.S. Well Services, LLC Gel Breakers Ammonium Persulfate 7727-54-0 100 0.0009 565
HCL Acid (12.6%-18.0%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 87.5 0.08957 56499.1
Hydrogen Chloride 7641-01-1 18 0.0214 13495.8
K-BAC 1020 U.S. Well Services, LLC Anti-Bacterial Agent Deionized Water 7732-18-5 28 0.00258 1627.63
2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.00452 2849.52
SI-1000 U.S. Well Services, LLC Scale Inhibitor Ethylene Glycol 107-21-1 20 0.00409 2578.44
Anionic Copolymer Proprietary 0 0.00452 2852.52
Water 7732-18-5 30 0.00341 2150.21
Water Antero Resources Base Fluid Water 7732-18-5 100 90.4082 57,026,300.0
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 9.30447 5,868,930.0
AI-300 U.S. Well Services, LLC Acid Corrosion Inhibitors Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.00006000 39.5566
2-Butoxyethanol 111-76-2 7 0.00006000 34.9417
Cinnamaldehyde 104-55-2 5 0.00006000 40.0996
Ethoxylated Nonylphenol 68412-54-4 5 0.00002000 10.7294
Isopropyl Alcohol 67-63-0 3 0.00001000 5.11263
N,N-Dimethylformamide 68-12-2 15 0.00007000 45.7099
Triethyl Phosphate 78-40-0 3 0.00001000 6.43765
Ethylene Glycol 107-21-1 31 0.00023 147.885
Water 7732-18-5 20 0.00002000 13.5734

For data sources see[4]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2013-10-13 H2O 15 5917 Bbl 6180 US Well Services Inc STAGE 27

60 SHOTS

2013-10-09 H2O 15 6134 Bbl 187310 US Well Services Inc STAGE 10

60 SHOTS

2013-10-11 H2O 15 5250 Bbl 202080 US Well Services Inc STAGE 19

60 SHOTS

2013-10-16 H2O 15 5845 Bbl 175770 US Well Services Inc STAGE 29

60 SHOTS

2013-10-10 H2O 15 5422 Bbl 218210 US Well Services Inc STAGE 14

60 SHOTS

2013-10-12 H2O 15 5181 Bbl 214940 US Well Services Inc STAGE 21

60 SHOTS

2013-10-08 H2O 15 5367 Bbl 216140 US Well Services Inc STAGE 7

60 SHOTS

2013-10-10 H2O 15 5188 Bbl 211340 US Well Services Inc STAGE 16

60 SHOTS

2013-10-11 H2O 15 5193 Bbl 208250 US Well Services Inc STAGE 23

60 SHOTS

2013-10-11 H2O 15 5994 Bbl 200280 US Well Services Inc STAGE 17

60 SHOTS

2013-10-13 H2O 15 4970 Bbl 202320 Superior Well Services STAGE 26

60 SHOTS

2013-10-17 H2O 15 5791 Bbl 198635 US Well Services Inc STAGE 30

60 SHOTS

2013-10-08 H2O 15 6170 Bbl 212440 US Well Services Inc STAGE 6

60 SHOTS

2013-10-10 H2O 15 5242 Bbl 215540 US Well Services Inc STAGE 15

60 SHOTS

2013-10-08 H2O 15 5487 Bbl 214930 US Well Services Inc STAGE 3

60 SHOTS

2013-10-08 H2O 15 5501 Bbl 215460 US Well Services Inc STAGE 5

60 SHOTS

2013-10-08 H2O 15 5443 Bbl 216020 US Well Services Inc STAGE 2

60 SHOTS

2013-10-09 H2O 15 5422 Bbl 215030 US Well Services Inc STAGE 9

60 SHOTS

2013-10-11 H2O 15 5193 Bbl 215890 US Well Services Inc STAGE 20

60 SHOTS

2013-10-12 H2O 15 5335 Bbl 216968 US Well Services Inc STAGE 22

60 SHOTS

2013-10-10 H2O 15 5323 Bbl 207580 US Well Services Inc STAGE 12

60 SHOTS

2013-10-09 H2O 15 5409 Bbl 215690 US Well Services Inc STAGE 11

60 SHOTS

2013-10-10 H2O 15 5420 Bbl 218160 US Well Services Inc STAGE 13

60 SHOTS

2013-10-12 H2O 15 6616 Bbl 170960 US Well Services Inc STAGE 25

60 SHOTS

2013-10-09 H2O 15 5293 Bbl 215500 US Well Services Inc STAGE 8

60 SHOTS

2013-10-12 H2O 15 4947 Bbl 120240 US Well Services Inc STAGE 24

60 SHOTS

2013-10-07 H2O 15 5620 Bbl 164940 US Well Services Inc STAGE 1

60 SHOTS

2013-10-08 H2O 15 5628 Bbl 218760 US Well Services Inc STAGE 4

60 SHOTS

2013-10-13 H2O 15 4253 Bbl 155480 US Well Services Inc STAGE 28

60 SHOTS

2013-10-11 H2O 15 5364 Bbl 217886 US Well Services Inc STAGE 18

60 SHOTS

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2013 ANTERO RESOURCES CORPORATION 0 676 0
2014 ANTERO RESOURCES CORPORATION 698044 51635 348
2015 ANTERO RESOURCES CORPORATION 234418 12713 363
2016 ANTERO RESOURCES CORPORATION 167958 7697 359
2017 ANTERO RESOURCES CORPORATION 135806 3941 365
2018 ANTERO RESOURCES CORPORATION 111912 3429 340
2019 ANTERO RESOURCES CORPORATION 24670 751 90

For data sources see[6] [7]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2013 ANTERO RESOURCES CORPORATION Brine 0 0
2014 ANTERO RESOURCES CORPORATION Brine 6468 348
2015 ANTERO RESOURCES CORPORATION Brine 6119 363
2016 ANTERO RESOURCES CORPORATION Brine 1893 359
2017 ANTERO RESOURCES CORPORATION Brine 1270 365
2018 ANTERO RESOURCES CORPORATION Brine 733 340
2019 ANTERO RESOURCES CORPORATION Brine 177 90

For data sources see[8] [9]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0176599631 2017-01-11 Production Wells No Violations The purpose of my inspection today is a status check on a producing well. There are six wells on this pad; 3412124408, 3412124409, 3412124407, 3412124471, 3412124472, and 3412124428. During my inspection the well was equipped with a production tree style wellhead. The production valves are open. The production equipment consists of six gas processing units, eighteen 400 barrel tanks within containment, and two flare stacks. The production records are current, identification is located on the wellhead, and there are no violations present.
0397331906 2013-11-22 Administrative Inspection No Violations At 7:48 p.m. I received a call from James Harvey of Antero. Mr. Harvey stated that a Meyers water truck had rolled over and spilled 5 gallons of motor oil and a minimal quantity of flow back water. He also stated that all fluids were cleaned and Hulls Environmental was on site to get soil samples. All contaminated soil will be removed.
0454049273 2013-12-18 Preliminary Restoration No Violations The preliminary restoration requirements have been met.
0677308600 2017-06-07 Production Wells No Violations The purpose of my inspection was a status check on a producing well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. Gauges present read 320 pounds per square inch on the casing and 260 pounds per square inch on the tubing. Annular pressure monitoring was present. The production equipment consists of eighteen 400 barrel tanks within a lined steel containment, six gas processing units within a lined steel containment, two compressor, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current, the identification was located at the wellhead and gas production unit, and there were no violations present.
0737873295 2013-12-18 Preliminary Restoration No Violations The preliminary restoration requirements have been met.
0810187447 2013-07-12 Casing String Witnessed No Violations I am onsite today to witness the running of surface casing. The rig crew ran casing to 516. At that point the casing became stuck and they lost circulation. The rig crew will attempt to wash down 1 tubing along side the casing in order to regain circulation.
0910202958 2013-07-17 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is drilling 17.5 hole at a depth of 1111.
0960551752 2015-04-02 Production Wells No Violations I am accompanied Inspector David Ball today. Our inspection finds the well appears capable of production with the production valves open. The tank battery is comprised of eighteen 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds five production units. The production equipment is shared with four other wells on the pad. Equipment associated with the recent stimulation activities is being removed from the site.
1287737615 2013-07-08 Drill / Deepen / Reopen No Violations The rig is bing moved to the well and preparing to drill the surface section of the hole to approximately 560
1334675724 2016-03-21 Production Wells No Violations My inspection today finds the well is equipped in a manner consistent with being capable of production with a tubing plunger lift system. The tank battery is comprised of eighteen 400 barrel tanks set in a liquid tight plastic lined steel containment. A separate containment area holds six production units. The production equipment is shared with five other wells on the pad.
1367426765 2013-04-26 Casing String Witnessed No Violations My inspection today finds the driller has made 1 of hole in 4 hours. Due to the hole conditions I have allowed the operator to run 86 of 26 conductor. Superior Well Service cemented the pipe in place with 278 sks of 15.6# cement. The cement stayed at surface.
1462448049 2013-07-25 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is drilling 12.25 hole at a depth of 3127. I tested a sample of water located next to the drilling additives containment area, for chlorides. The water did not contain elevated chloride levels. (tested with Quantabs)
1510348739 2017-11-07 Production Wells No Violations The purpose of my inspection was a status check on a production well. The pad is named Rich and there are a total of six wells on this pad. During my inspection the well was equipped with a production tree style wellhead and a plunger lift system with production valves in the open position. The production equipment consisted of eighteen 400 barrel tanks within a lined steel containment, six gas production units within a lined steel containment, one vent scrubber, two compressors, and two combustors. The pipeline tie in is located on the north side of the pad. The production records are current and the identification was located at the wellhead.
1718652464 2018-06-12 Production Wells No Violations The purpose of my inspection was a status check. The well was equipped with a production tree style wellhead with a plunger lift system. Production valves were in the open position. A gauge was present on the production tubing reading 302 pounds per square inch, 350 pounds per square inch on the production casing, 350 pounds per square inch on the 9.625 inch diameter intermediate casing, and 0 pounds per square inch on the 13.375 inch diameter surface casing. The production equipment consisted of eighteen 400 barrel tanks, six gas production units, and two combustors. The identification was located at the wellhead.
1775166437 2013-07-14 Casing String Witnessed No Violations My inspection today finds the operator has regained circulation and the current depth of casing is 2 below the permit required depth. Nabors Well Service cemented 492 (ground level) of 18.625 casing in place with 1202 sks of cement. I witnessed 90 bbl of cement returns to surface.
1886765760 2013-07-15 Drill / Deepen / Reopen No Violations My inspection today finds the drilling rig is tripping in the hole and preparing to drill the 17.5 section of the well.
1969287941 2018-11-01 Production Wells No Violations On the day of my inspection I witnessed that the well was equipped with 5.5-inch diameter production casing and 2.875-inch diameter tubing equipped with a plunger lift system. At the time of my inspection annular pressure monitoring was in place, and the 13.375-inch diameter casing had 340 pounds per square inch, the 9.625-inch diameter casing had 0 pounds per square inch. Production equipment included a Gas Processing Unit, as well as 6- 400-barrel steel production fluid tanks, and 2 combustors that were shared with the other producing wells on the pad. There was secondary containment around the production fluid tanks, and the Gas Processing Units. The well pad was contained within an earthen dike, there were multiple Emergency Shutoff Devices on location. Identification tags were present, and production was up to date.
2030301767 2014-03-31 Production Wells No Violations My inspection finds well is in production. The tank battery consists of eighteen 400 bbl tanks that are shared with three other wells. The identification is posted as required. The well site is being prepared for a drilling rig.

For data sources see[10]

References