34-153-22324

Well Details

Well ID: 34-153-22324
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Green
Operator Name: SKYLINER ENERGY LLC
Well Pad ID:
Farm/Lease Name: RUBBER CITY SAND & GRAVEL
License Status: Producing
License Date: 1986-11-19
Spud Date: 1986-12-13
Spud Drilling Contractor: RAPID DRILLING
Final Drill Date: 1986-12-19
Well Total Depth: 4383 ft
Configuration: Vertical
Latitude: 40.981725978
Longitude: -81.43297129

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1986-11-19 Issued Date 11/19/86 Expired Date 11/19/87 Acres 0000000 Tool Type RTF Proposed Formation CLINTON Proposed Depth 04383 Proposed Drill Depth 04383
Original Spud 1986-12-13
Completed 1986-12-19
Reached Total Depth 1986-12-19
CO 1987-01-14 1304 SEAGULL DEVELOPMENT CORP GeoDate 11/19/86
Completion Report Received 1987-02-03
Construction Permit Expires 1987-11-19
CO 1988-12-08 3103 LEAGUE DEVELOPMENT CO INC GeoDate 11/19/86
CO 1989-11-28 3442 CUTTER EXPLORATION INC GeoDate 11/19/86
Change of Owner 2015-03-09 Operator changed from 3442, CUTTER EXPLORATION INC to 9429, SKYLINER ENERGY LLC
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4201 4269 0
2006-09-11 4213 4268 36

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 91320 Gal 0 FRAC W/91,320 GAL H20,250 SX SAND
N2 0 180 Mscf 25000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1987 SEAGULL DEVELOPMENT CORP 29238 404 329
1988 SEAGULL DEVELOPMENT CORP 38370 394 365
1989 CUTTER EXPLORATION INC 52409 307 365
1990 CUTTER EXPLORATION INC 36003 290 365
1991 CUTTER EXPLORATION INC 31466 157 365
1992 CUTTER EXPLORATION INC 14653 181 365
1993 CUTTER EXPLORATION INC 20117 96 365
1994 CUTTER EXPLORATION INC 17027 204 365
1995 CUTTER EXPLORATION INC 18951 68 365
1996 CUTTER EXPLORATION INC 15530 120 365
1997 CUTTER EXPLORATION INC 16141 82 365
1998 CUTTER EXPLORATION INC 12370 96 365
1999 CUTTER EXPLORATION INC 12938 75 365
2000 CUTTER EXPLORATION INC 12690 54 365
2001 CUTTER EXPLORATION INC 11541 96 365
2002 CUTTER EXPLORATION INC 9453 33 365
2003 CUTTER EXPLORATION INC 7693 17 365
2004 CUTTER EXPLORATION INC 8020 36 365
2005 CUTTER EXPLORATION INC 8771 26 365
2008 CUTTER EXPLORATION INC 8796 31 365
2009 CUTTER EXPLORATION INC 6245 0 365
2010 CUTTER EXPLORATION INC 4908 0 365
2011 CUTTER EXPLORATION INC 6746 65 0
2012 CUTTER EXPLORATION INC 6249 41 366
2013 CUTTER EXPLORATION INC 4706 0 365
2014 CUTTER EXPLORATION INC 2515 0 365
2015 CUTTER EXPLORATION INC 463 0 125
2016 SKYLINER ENERGY LLC 1163 0 365
2017 SKYLINER ENERGY LLC 0 1817 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1987 SEAGULL DEVELOPMENT CORP Brine 1725 329
1988 SEAGULL DEVELOPMENT CORP Brine 475 365
1989 CUTTER EXPLORATION INC Brine 355 365
1990 CUTTER EXPLORATION INC Brine 455 365
1991 CUTTER EXPLORATION INC Brine 455 365
1992 CUTTER EXPLORATION INC Brine 401 365
1993 CUTTER EXPLORATION INC Brine 280 365
1994 CUTTER EXPLORATION INC Brine 360 365
1995 CUTTER EXPLORATION INC Brine 210 365
1996 CUTTER EXPLORATION INC Brine 280 365
1997 CUTTER EXPLORATION INC Brine 210 365
1998 CUTTER EXPLORATION INC Brine 70 365
1999 CUTTER EXPLORATION INC Brine 270 365
2000 CUTTER EXPLORATION INC Brine 260 365
2001 CUTTER EXPLORATION INC Brine 210 365
2002 CUTTER EXPLORATION INC Brine 140 365
2003 CUTTER EXPLORATION INC Brine 325 365
2004 CUTTER EXPLORATION INC Brine 401 365
2005 CUTTER EXPLORATION INC Brine 155 365
2008 CUTTER EXPLORATION INC Brine 110 365
2009 CUTTER EXPLORATION INC Brine 145 365
2010 CUTTER EXPLORATION INC Brine 0 365
2011 CUTTER EXPLORATION INC Brine 18
2012 CUTTER EXPLORATION INC Brine 12 366
2013 CUTTER EXPLORATION INC Brine 0 365
2014 CUTTER EXPLORATION INC Brine 0 365
2015 CUTTER EXPLORATION INC Brine 0 125
2016 SKYLINER ENERGY LLC Brine 0 365
2017 SKYLINER ENERGY LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0873936638 2003-03-26 Production Wells No Violations The tank battery has been dismantled and impacted soil was removed on 3/24. Supr. Cheslock witnessed a portion of the removal. Replacement tanks are to be installed later this week.
0941102665 2003-03-06 Production Wells No Violations During a status check inspection, the 210 bbl stock tank was found to have holes approximately six feet above ground level and was seeping oil and incapable of containing product. The 210 bbl tank is in very poor condition and needs to be properly repaired or replaced. There was also no identification at the wellhead. The three Rubber City wells have a common tank battery with three 210 bbl tanks, one 100 bbl tank and three horizontal separators. I contacted Dan Long (330-866-3558), the pumper for Cutter and informed him of the problems.
1138110982 2006-01-10 Production Wells No Violations Status check inspection - no violations at this time.
1454378560 2003-04-04 Production Wells No Violations The violations have been corrected and the operator has been given permission to turn the well back into line.
1454611002 2016-01-26 UrbanProduction Wells Violations Noted The Rubber City Sand and Gravel # 3 well was drilled and completed in 2/1987. A review of the RBDMS data base indicates that the well is current in the reporting of the production volumes. The well construction is 8.625 surface casing is set at 505, 4.5 production casing set at 4354 and 1.5 tubing set at 4170. The well is operated as a plunger lift well on a Logic controller. The required identifying signage, at the wellhead, does not reflect the current Operator. The fencing around the wellhead is in need of repair and a lock to maintain security. The well location is located in a high density residential area and the landowner allowed that he has incidents with trespassers previously. There are numerous leaks on the wellhead. The Demco gate valve ( 1.5 tubing ) is leaking and the top joint of 1.5 tubing appears to be also leaking. These leaks are running down the tubing head and 8.625 casing head to the ground. The motor valve is also leaking but is not causing ground contamination at this time. The 8.625 casing head has two ( 2) outlets opened to the atmosphere. There are not any valves or bull plugs in the outlets. The tank battery is shared with the Rubber City Sand and Gravel # 2 ( 34-153-2-2250, Skyliner Energy ) . The Rubber City Sand and Gravel # 3 well has a 100 barrel oil tank and a 2408 mechanical separator. The tank battery was fenced, locked and secured. The 100 barrel oil tank had the required identifying signage reflecting the current Operator. I did not identify any leaks or violations associated with the tank battery for the Rubber City Sand and Gravel # 3 well. A coated gas sales line to Dom / EOG is on top of the ground, unburied for approximately 30 heading east from the tank battery toward Myersville Road. In order to bring the Rubber City Sand and Gravel # 3 well into compliance the Operator shall : 1.) Post the required identifying signage at the wellhead within two (2) weeks of receipt of notice - OAC 1501:9-9-05 ( 10 ) , 2.) Operator shal
1549982278 2019-02-12 Production Wells No Violations My inspection found the well is has partially complied with the Compliance Notice issued on 01-26-2016. The well is equipped with a plunger lift system and it is not leaking. The well is overgrown with woody-stemmed vegetation making it difficult to access. The tank battery consists of a steel production tank, a horizontal separator and a meter. The well is legibly identified. The coated section of sales line hs not been buried. I called 330-897-1899 there was no answer and I was unable to leave a message.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1454611002 US-OH-113146 2019-02-08 9-05E1 ID (a-i)
1454611002 US-OH-113147 2019-02-08 9-10-05 Failure to properly bury pipeline
1454611002 US-OH-113148 2019-02-08 9-1-07 Well operation causing pollution and contamination
1454611002 US-OH-113149 2019-02-08 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas

For data sources see[9]