Well Details

Well ID: 34-153-23124
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Norton
Operator Name: INDUSTRY STANDARD SUPPLIES INC
Well Pad ID:
Farm/Lease Name: JOHNSON UNIT
License Status: Producing
License Date: 2011-05-20
Spud Date: 2010-11-01
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 2010-11-07
Well Total Depth: 3902 ft
Configuration: Vertical
Latitude: 41.047406467
Longitude: -81.65792438

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-10-18 Proposed Formations:CLINTON, Issued Date:10/18/2010, Expired Date:10/17/2012 12:00:00 PM, Drilling unit acres:21.01, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-11-07
Completion Report Received 2011-02-17
Construction Permit Expires 2011-10-18
Record Last Modified 2017-10-24

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-05-20 3730 3750 21
2011-05-20 3764 3770 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-12-03 H2O 15 54690 Gal 30000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2011 INDUSTRY STANDARD SUPPLIES INC 4857 722 306
2012 INDUSTRY STANDARD SUPPLIES INC 4575 627 366
2013 INDUSTRY STANDARD SUPPLIES INC 1720 478 365
2014 INDUSTRY STANDARD SUPPLIES INC 2998 360 365
2015 INDUSTRY STANDARD SUPPLIES INC 3641 345 365
2016 INDUSTRY STANDARD SUPPLIES INC 2646 114 365
2017 INDUSTRY STANDARD SUPPLIES INC 2191 220 365
2018 INDUSTRY STANDARD SUPPLIES INC 1814 112 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2011 INDUSTRY STANDARD SUPPLIES INC Brine 0 306
2012 INDUSTRY STANDARD SUPPLIES INC Brine 0 366
2013 INDUSTRY STANDARD SUPPLIES INC Brine 70 365
2014 INDUSTRY STANDARD SUPPLIES INC Brine 65 365
2015 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2016 INDUSTRY STANDARD SUPPLIES INC Brine 71 365
2017 INDUSTRY STANDARD SUPPLIES INC Brine 0 365
2018 INDUSTRY STANDARD SUPPLIES INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0239164036 2010-11-04 Urban Drill / Deepen / Reopen No Violations G&H is drilling ahead on fluid. The pits are fenced, lined and in good condition.
0791218496 2011-01-25 Urban Drill / Deepen / Reopen No Violations A pump jack has not yet been set on the well which has been equipped with rods. The tank battery is being constructed. The required security fence has not been started but will need to be completed before turn on. No indication from the company as to when the well will be ready for turned on. Preliminary restoration is due this spring.
0969722324 2010-12-22 Urban Drill / Deepen / Reopen No Violations The well has been fraced and the tank battery has been built. ISSI still needs to set a pump jack and install the security fencing before turn on.
1208343467 2010-10-28 Urban Drill / Deepen / Reopen No Violations The location has been built and G&H Drilling is starting to move in.
1291045342 2010-11-19 Urban Drill / Deepen / Reopen No Violations Witness pit solidification. Chemtech delivered and applied two loads of dust to the drilling pits. The landowner requested that the stumps be placed in the pits before they are covered over. He also requested that the tank battery be moved approximately 50 feet to the northeast. I advised the operator and the landowner of the minimum spacing requirements that must be met.
1328418953 2011-07-06 Preliminary Restoration No Violations Industry Standard has a contractor on site grading the location and spreading topsoil. The affected area should be ready to seed within a week. The security fencing is up and the well is in production.
1397008601 2010-11-01 Urban Drill / Deepen / Reopen No Violations G&H Drilling moved on location this past weekend and spudded the well this morning. The drilling pits were lined, fenced and in good condition. This is an urban location. No violations at this time.
1399591150 2010-11-02 Urban Drill / Deepen / Reopen No Violations G&H Drilling is coming out from under surface cement and drilling the 7-7/8 main hole with fresh water. They will drill the well with fluid. The pits are fenced, lined and in good condition. No violations at this time.
1443445660 2013-06-06 UrbanProduction Wells No Violations I inspected this well site on 6/6/2013 as a follow up to Complaint # 4342 of a neighboring Landowner concerning oil in the Dominion/ East Ohio Gas lines servicing a residence at 3126 Clubside Drive. The Johnson Unit # 1 well is operated by an electrified pump jack. The tank battery consists of a 210 barrel oil tank, 30 barrel poly brine tank and a horizontal 2408 mechanical separator with a positive shut off drip. I spoke with the complainant, by phone, and relayed my conservation with Mr. Tim Levengood ( Industry Standard Supplies, Inc. ). Mr. Levengood told me that the positive shut off drip had failed to operate as designed and allowed oil to pass into Dominion/ East Ohio Gas distribution lines. The offending drip tank has been fixed and now is fucntional. No violation identified at this time.
1654383073 2010-11-16 Urban Drill / Deepen / Reopen No Violations The drilling pits have been pumped down, are still lined and fenced. Solidification is scheduled for 11/19.
1663160904 2010-10-27 Urban Drill / Deepen / Reopen No Violations The drilling location is being built. The rig is scheduled to arrive later this week.
1910749422 2011-12-14 Preliminary Restoration No Violations Preliminary Restoration is approved.
1971344387 2011-03-04 Production Wells No Violations Status check inspection found that the pump jack was installed and pumping. The fence has been installed around the tank battery but not around the wellhead. I called Tim Levengood and told him to shut the well down until all of the fence was installed. There is also a question as to the legality of one of the leases in this unit. Columbus has requested but not yet received additional documentation from ISSI.

For data sources see[9]