If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-169-25432 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.889492315,"lon":-81.98858231,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Wayne | |
Municipality: Wayne Township | |
Operator Name: HARLEY DRILLING & PRODUCING LT | |
Well Pad ID: | |
Farm/Lease Name: JONES | |
License Status: Producing | |
License Date: 2013-06-24 | |
Spud Date: 2002-03-07 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2002-03-14 | |
Well Total Depth: 5584 ft | |
Configuration: Vertical | |
Latitude: 40.889492315 | |
Longitude: -81.98858231 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2002-02-05 | Proposed Formations:CLINTON/TREMPEALEAU, Issued Date:2/5/2002, Expired Date:2/5/2003 6:00:00 AM, Drilling unit acres:271.7, Proposed Well Type:OG, Proposed Well Class:POOL |
Original Spud | 2002-03-07 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
Completed | 2002-03-14 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
Reached Total Depth | 2002-03-14 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
Plugged Back | 2013-05-27 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
APP | 2013-06-05 | Proposed Formations:CLINTON, Issued Date:6/5/2013, Expired Date:6/5/2015 12:00:00 PM, Drilling unit acres:271.7, Proposed Well Type:OG, Proposed Well Class:POOL |
Completion Report Received | 2014-07-24 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
Construction Permit Expires | 2015-06-05 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
Record Last Modified | 2017-10-24 | PLUG BACK FORMATION IS THE CLINTON FORMATION, PREPOSED PLUG BACK DEPTH WAS 3400 BUT DO NOT KNOW AT THIS TIME WHAT IT ACTUALLY WAS.| |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2002-08-29 | 5530 | 5546 | 48 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
ACID | 15 | 1250 Gal | 0 | |||
2013-09-30 | H2O | 0 | 78030 Gal | 0 | Producers Service Corporation | Notified but unable to witness. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | HARLEY DRILLING & PRODUCING LT | 4313 | 503 | 245 |
2003 | HARLEY DRILLING & PRODUCING LT | 11363 | 1048 | 365 |
2004 | HARLEY DRILLING & PRODUCING LT | 3823 | 883 | 365 |
2005 | HARLEY DRILLING & PRODUCING LT | 1193 | 353 | 365 |
2006 | HARLEY DRILLING & PRODUCING LT | 1653 | 178 | 365 |
2007 | HARLEY DRILLING & PRODUCING LT | 3566 | 174 | 365 |
2008 | HARLEY DRILLING & PRODUCING LT | 3125 | 0 | 365 |
2009 | HARLEY DRILLING & PRODUCING LT | 3170 | 0 | 365 |
2010 | HARLEY DRILLING & PRODUCING LT | 2631 | 0 | 365 |
2011 | HARLEY DRILLING & PRODUCING LT | 2867 | 0 | 365 |
2012 | HARLEY DRILLING & PRODUCING LT | 2913 | 1296 | 366 |
2013 | HARLEY DRILLING & PRODUCING LT | 0 | 0 | 365 |
2014 | HARLEY DRILLING & PRODUCING LT | 105 | 524 | 365 |
2015 | HARLEY DRILLING & PRODUCING LT | 0 | 1209 | 365 |
2016 | HARLEY DRILLING & PRODUCING LT | 0 | 529 | 365 |
2017 | HARLEY DRILLING & PRODUCING LT | 0 | 521 | 365 |
2018 | HARLEY DRILLING & PRODUCING LT | 0 | 348 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2002 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 245 |
2003 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2004 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2005 | HARLEY DRILLING & PRODUCING LT | Brine | 30 | 365 |
2006 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2007 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2008 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2009 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2010 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2011 | HARLEY DRILLING & PRODUCING LT | Brine | 80 | 365 |
2012 | HARLEY DRILLING & PRODUCING LT | Brine | 163 | 366 |
2013 | HARLEY DRILLING & PRODUCING LT | Brine | 140 | 365 |
2014 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2015 | HARLEY DRILLING & PRODUCING LT | Brine | 15 | 365 |
2016 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2017 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
2018 | HARLEY DRILLING & PRODUCING LT | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0016176021 | 2002-03-11 | Drill / Deepen / Reopen | No Violations | Cpstar Drilling is at 4121 ft soaping on 77/8 hole . Check pits and bop equipment and found everything in place and chained and staked. |
0016576025 | 2002-03-18 | Drill / Deepen / Reopen | No Violations | Rig has moved and pit level is good and liner is in place. |
0018876043 | 2002-04-02 | Production Wells | No Violations | Pits closed and area needs graded and seeded. |
0048846901 | 2004-02-11 | Preliminary Restoration | No Violations | Meets requirements for preliminary restoration. |
0064596521 | 2018-03-07 | Production Wells | No Violations | Inspected production well on 03/07/2018. The tank battery consists of 1-210 bbl steel tank, 1-vertical separator, 1-drip, 1-meter box, 1-compressor, and 1-underground brine vault (shared), located within an earthen dike; the diked area and noted equipment are shared with the Jentes-Jones #H-3 and #H-6 wells (PN: 169-25420/25561). The well is equipped with a pump jack with an electric motor. A small earthen dike is present around the wellhead. Well identification is clearly displayed at both the tank battery and the wellhead. The well is located ~200 from its RBDMS location. A map showing the location discrepancy and a request that the location be updated in RBDMS was sent to Gregg Miller (DOGRM Columbus). No other problems were noted at the time of the inspection. |
0118711185 | 2003-03-25 | Production Wells | Violations Noted | Identification needs posted at the tank battery or wellhead . The restoration needs t be done again as vegetation is very low . |
0327358752 | 2003-03-31 | Preliminary Restoration | No Violations | |
0720321349 | 2007-01-18 | Production Wells | No Violations | Violation corrected . |
0836867963 | 2012-11-29 | Production Wells | No Violations | This is a producing pump jack well. There were no problems noted at the time of the inspection. |
0942983197 | 2016-03-09 | Production Wells | No Violations | Inspected production well on 03/09/2016. The tank battery consists of 3-210 bbl steel tanks, 1-horizontal separator, 2-vertical separators, 1-underground brine vault, and 1-compressor located within an earthen dike. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. The well is not located in its RBDMS location. No other problems were noted at the time of the inspection. |
1092606960 | 2013-09-26 | Production Wells | No Violations | On site today to check on the status. Reinstalled 4 1/2 casing on 9/24 (see casing ticket,) and frac tanks being filled, perforators scheduled for this morning. |
1198364973 | 2017-02-01 | Preliminary Restoration | No Violations | Inspected production well on 02/01/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1379946046 | 2013-09-23 | Plug / Plug Back | No Violations | On location today checking on progress for re-installing 4 1/2 casing. Casing was cut @ 4420 feet, and is being removed to check for bad joints. Bad joints will be replaced, casing ran back in and then cemented to produce from the Clinton zone. Was was previously plugged back from the Trempealeu. |
1474097512 | 2014-12-16 | Production Wells | No Violations | This is a pump jack well. There are no evident problems at this time. |
1819540132 | 2017-02-01 | Production Wells | No Violations | Inspected production well on 02/01/2017. The tank battery consists of 3-210 bbl steel tanks, 1-horizontal separator, 2-vertical separators, 1-compressor, and 1-underground brine vault, located within an earthen dike; the diked area is shared with the tank battery for the Jones #2 and Jentes-Jones #H-6 wells (PN: 169-24148/25561). The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. The well is ~200 from its RBDMS location. No other problems were noted at the time of the inspection. |
1975520347 | 2016-08-09 | Production Wells | No Violations | Inspected production well on 08/09/2016. The tank battery consists of 3-210 bbl steel tanks, 2-vertical separators, 1-horizontal separator, 1-compressor, and 1-underground brine vault, located within an earthen dike. The underground brine vault is also used by the Jones #2 and Jones #H-6 wells. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is equipped with a pump jack with an electric motor. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0118711185 | US-OH-104972 | 2003-03-28 | Failure to legibly identify well |
For data sources see[9]