X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21816

Well Details

Well ID: 34-035-21816
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Independence
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: INDEPENDENCE RESEARCH CENTER
License Status: Producing
License Date: 2005-04-28
Spud Date: 2004-10-05
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2004-10-09
Well Total Depth: 3325 ft
Configuration: Vertical
Latitude: 41.378081306
Longitude: -81.63534970

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2004-09-23 Proposed Formations:OIHO SHALE ,ORISKANY,NEWBURG, CLINTON, Issued Date:9/23/2004, Expired Date:9/23/2005 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2004-10-05 RBDMS Rec
Completed 2004-10-09 RBDMS Rec
Reached Total Depth 2004-10-09 RBDMS Rec
Completion Report Received 2005-03-02 RBDMS Rec
Construction Permit Expires 2005-09-23 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2005-04-28 3129 3148 39

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 55999 Gal 35000 500 GALLONS HCL ACID…WELL KICKED OFF & FLOWED 234 BARRELS OF OIL IN 1ST 24 HOURS AFTER FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2005 BASS ENERGY CO INC 6971 3922 365
2006 BASS ENERGY CO INC 7601 4374 365
2007 BASS ENERGY CO INC 6350 3243 365
2008 BASS ENERGY CO INC 6195 2763 365
2009 BASS ENERGY CO INC 6305 2301 365
2010 BASS ENERGY CO INC 6159 1571 365
2011 BASS ENERGY CO INC 4273 1456 0
2012 BASS ENERGY CO INC 4190 1417 366
2013 BASS ENERGY CO INC 2778 1301 365
2014 BASS ENERGY CO INC 2708 1188 365
2015 BASS ENERGY CO INC 2551 969 365
2016 BASS ENERGY CO INC 1811 966 365
2017 BASS ENERGY CO INC 1961 888 365
2018 BASS ENERGY CO INC 1576 709 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2005 BASS ENERGY CO INC Brine 458 365
2006 BASS ENERGY CO INC Brine 20 365
2007 BASS ENERGY CO INC Brine 0 365
2008 BASS ENERGY CO INC Brine 65 365
2009 BASS ENERGY CO INC Brine 35 365
2010 BASS ENERGY CO INC Brine 0 365
2011 BASS ENERGY CO INC Brine 0
2012 BASS ENERGY CO INC Brine 38 366
2013 BASS ENERGY CO INC Brine 18 365
2014 BASS ENERGY CO INC Brine 0 365
2015 BASS ENERGY CO INC Brine 28 365
2016 BASS ENERGY CO INC Brine 15 365
2017 BASS ENERGY CO INC Brine 0 365
2018 BASS ENERGY CO INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0098893827 2015-03-02 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The wellhead and battery are located with in the confines of the Cleveland Clinic Home Care office facility on Brecksville Road. The wellhead is comprised of a mechanical plunger lift in a chain-link enclosure. The battery is comprised of 2 100-barrel production tanks, 2 50-barrel brine tanks, separators inside a separate chain-link enclosure. The battery is shared with the #2-1833 well. Fittings and connections at the wellhead are secure and free from signs of leakage. Gates and load-outs are secure and locked. Signage is present and complete. I did not observe any evidence of impact relating to on-going production activity.
0202465873 2010-01-27 Production Wells No Violations No violations!
0381328757 2004-10-06 Drill / Deepen / Reopen No Violations Drilling at 890 no gas encounter in shale
1036977033 2017-08-28 UrbanProduction Wells No Violations I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery, shared with the Independence Research Park #2D, located on the Cleveland Clinic facility. Fittings and connections at the wellhead and battery were secure. The enclosure gates were secure. The load-lines were secure. The secondary containment was intact and dry. I found no signs of problems at this inspection.
1100526032 2004-10-06 Drill / Deepen / Reopen No Violations drilling at890 hit gas at 340
1167764972 2006-12-05 Production Wells No Violations
1260052908 2006-04-14 Production Wells No Violations Tank Battery and well
1486527601 2004-10-05 Drill / Deepen / Reopen No Violations surface
1719864848 2005-10-07 Preliminary Restoration No Violations
1827837882 2013-09-23 UrbanProduction Wells No Violations The wellhead mechanical plunger lift and aboveground (AST) battery are enclosed in separate chain-link fences. The well is producing. The battery is comprised of 4 100-barrel steel production tanks and 1 50-barrel steel brine tank. Spacing and safety equipment are in accordance with rules. Gates are locked and ID placard is present. Secondary containment is adequate. The battery is shared with the #1833 unit. No problems or violations.

For data sources see[9]

References