X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-22156

Well Details

Well ID: 34-035-22156
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality:
Operator Name: BAAY OIL LLC
Well Pad ID:
Farm/Lease Name: WOODHAWK CLUB UNIT
License Status: Producing
License Date: 2011-09-22
Spud Date: 2010-06-11
Spud Drilling Contractor: POULSON DRILLING
Final Drill Date: 2010-06-17
Well Total Depth: 3624 ft
Configuration: Vertical
Latitude: 41.509303889
Longitude: -81.45056451

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2010-04-08 Proposed Formations:OHIO SHALE, ORISKANY, NEWBURG, CLINTON, Issued Date:4/8/2010, Expired Date:4/8/2011 6:00:00 AM, Drilling unit acres:44.21, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2010-06-17 STATUS BASED ON LOG REC'D
Construction Permit Expires 2011-04-08 STATUS BASED ON LOG REC'D
Completion Report Received 2011-07-13 STATUS BASED ON LOG REC'D
Change of Owner 2016-01-29 Operator changed from 1304, SEAGULL DEVELOPMENT CORP to 8560, BAAY OIL LLC
Record Last Modified 2017-10-24 STATUS BASED ON LOG REC'D

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2011-09-22 3443 3484 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
2010-04-27 H2O 0 61296 Gal 25000 Superior Well Services

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2010 SEAGULL DEVELOPMENT CORP 0 0 0
2011 SEAGULL DEVELOPMENT CORP 78279 59 365
2012 SEAGULL DEVELOPMENT CORP 56204 44 366
2013 SEAGULL DEVELOPMENT CORP 26172 0 365
2014 SEAGULL DEVELOPMENT CORP 16373 0 365
2015 SEAGULL DEVELOPMENT CORP 14684 0 365
2016 BAAY OIL LLC 11025 56 365
2017 BAAY OIL LLC 11660 0 365
2018 BAAY OIL LLC 9786 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2010 SEAGULL DEVELOPMENT CORP Brine 710 0
2011 SEAGULL DEVELOPMENT CORP Brine 260 365
2012 SEAGULL DEVELOPMENT CORP Brine 135 366
2013 SEAGULL DEVELOPMENT CORP Brine 0 365
2014 SEAGULL DEVELOPMENT CORP Brine 84 365
2015 SEAGULL DEVELOPMENT CORP Brine 41 365
2016 BAAY OIL LLC Brine 0 365
2017 BAAY OIL LLC Brine 0 365
2018 BAAY OIL LLC Brine 69 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0329992652 2016-02-02 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: Ingress and egress to and from the well area is afforded by the shared asphalt-paved entrance drive, and parking areas for the Woodhawk Condominium facility. A wellhead with mechanical plunger lift system is located in a board-on-board enclosure near the front entrance gate, in a small grassy landscaped area off the parking lot. The well enclosure was locked and secure. Fittings and connections at the wellhead were secure and free from leakage. The 8.625-inch casing annulus was exposed and plumbed into the system. Areas around the wellhead consist of turf grass which was free from signs of stress or impact. The tank battery is located 1,500 feet to the west, behind the tennis courts at the end of Quail Roost Drive, behind the tennis courts. The battery is comprised of one 100-barrel, low-boy steel production tank, one 50-barrel poly brine tank. At the time of this inspection, the access gate to the battery was locked and secure. Signage was present. Fittings and connections were secure and free from signs of leakage or problems. Process safety gear and carbon filter system was present. Secondary containment was intact and dry. Tank lids are closed and latched. The load-outs were plugged and locked. I walked the area surrounding the battery and observed normal grassy vegetation with no signs of erosional deficits or impacts associated with the production operation.
0458768987 2010-04-11 Drill / Deepen / Reopen No Violations On site for BOP test. Closed BOP at 350psi, pressured hole to 190psi, test was for 15 minutes, 10psi pressure lose during test, 5.2% lose of pressure BOP passed. Pits and linear were in good repair. Safety fence was up. Permit was posted in the dog house. Two fire extinguishers in the dog house (charged), one on the boom (not inspected), one on the mud pump (charged) and one by the engine on the rig (charged). Site was in good repair.
0818618918 2011-12-28 UrbanPreliminary Restoration No Violations On 12/28/2012, DNR Inspector Richard Skidmore completed an urban preliminary restoration well inspection for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed.
0862160881 2015-12-10 UrbanProduction Wells No Violations I inspected this producing well as part of routine inspection activity. The well and battery are located within the Woodhawk Condominium complex. Tank battery valves and fittings were secure. Tank lids were closed and secure. Fittings and connections at the wellhead were secure and free from signs of leakage or problems. The wellhead enclosure area was well maintained. The 8.625-inch casing was valved and gauged. Areas surrounding the wellhead are comprised of asphalt-paved parking and drive areas. The battery is located near the maintenance shop in an area utilized for material storage and other maintenance activity. I did not note any signs or evidence of impact relating to the production activity.
0875953674 2010-04-12 Drill / Deepen / Reopen No Violations Drilling at 1120 No odors present checked with gas meter no readings

No violation.

1086050813 2010-04-10 Drill / Deepen / Reopen No Violations cemented conductor.
1366610896 2010-04-17 Urban Drill / Deepen / Reopen No Violations 3611 feet of production casing was installed and cemented.
1450037862 2012-03-06 UrbanProduction Wells No Violations No violations found, well is in compliance.
1682073566 2010-03-29 Administrative Inspection No Violations Held on site meeting to discuss the on site construction and permitn conditions.
1786623495 2010-04-11 Drill / Deepen / Reopen No Violations cemented conductor casing.
1844262776 2010-04-11 Drill / Deepen / Reopen No Violations surface cementing good returns to surface.
1955290958 2010-03-29 Drill / Deepen / Reopen No Violations Held presite meeting to discuss permit conditions for the well.
1958162413 2010-04-27 Drill / Deepen / Reopen No Violations meeting at Uniontown office to review bond log because cement not covering lockport by 100 meeting determined not gas encountered in newburg zone. Rick Simmer Oked company to proceed with stimulation of well.
1962278214 2017-10-04 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. The well and associated battery are located within a multi-tenant residential community. The wellhead plunger-lift and battery are in separate, board-on-board enclosures. The enclosure gates were locked and secure. The load-line valves were locked, plugged, and secure. The secondary containment was intact. I walked the areas surrounding the well and battery and found not evidence of problems, or impacts to the surrounding greenscape. I noted that the ID signage at the wellhead had not been updated to reflect the new owner. I notified BAAY Oil about the need to update the signage.
2083899026 2013-07-24 UrbanProduction Wells No Violations The producing unit consists of a wellhead with mechanical plunger-lift unit and above-ground storage tank (AST) battery, The wellhead is located in a board-on-board enclosure which is locked. The well is currently producing. There is not ID at the wellhead. I did not observe any signs of leakage or problems. The AST battery is comprised of one 140-barrel production tank, one 50-barrel brine tank, and mechanical separator in a board-on-board enclosure. There is a unit ID at the wellhead. Secondary containment is good.
2132032583 2010-06-01 Drill / Deepen / Reopen No Violations Ground leveled around well siteand an temporary fencing (chain link) up around well.

For data sources see[9]

References