Well ID: 34-035-22046 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.332008592,"lon":-81.71395293,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Cuyahoga | |
Municipality: Royalton Township | |
Operator Name: EOS ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: VALLEY VISTA UNIT | |
License Status: Producing | |
License Date: 2009-01-20 | |
Spud Date: 2008-07-28 | |
Spud Drilling Contractor: CAPSTAR DRILLING | |
Final Drill Date: 2008-08-03 | |
Well Total Depth: 3592 ft | |
Configuration: Vertical | |
Latitude: 41.332008592 | |
Longitude: -81.71395293 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2008-07-03 | Proposed Formations:CLINTON, Issued Date:7/3/2008, Expired Date:7/3/2009 6:00:00 AM, Drilling unit acres:26.2532, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2008-08-03 | |
Completion Report Received | 2008-12-23 | |
Construction Permit Expires | 2009-07-03 | |
Correction to Well | 2010-01-15 | UNIT SIZE DECREASED TO 20.6371 ACRES. |
Correction to Well | 2010-04-02 | UNIT SIZE REDUCED TO 20.1811 ACRES. |
Correction to Well | 2010-07-16 | UNIT SIZE REDUCED TO 25.7092 ACRES. |
Change of Owner | 2018-07-31 | Operator changed from 1249, CUTTER OIL COMPANY to 10185, EOS ENERGY LLC |
Record Last Modified | 2018-07-31 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2009-01-20 | 3382 | 3416 | 35 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 200 Mscf | 60000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER OIL COMPANY | 3009 | 0 | 94 |
2009 | CUTTER OIL COMPANY | 26365 | 15543 | 365 |
2010 | CUTTER OIL COMPANY | 34978 | 11444 | 365 |
2011 | CUTTER OIL COMPANY | 26156 | 4778 | 365 |
2012 | CUTTER OIL COMPANY | 16722 | 1943 | 366 |
2013 | CUTTER OIL COMPANY | 12603 | 1428 | 365 |
2014 | CUTTER OIL COMPANY | 9351 | 940 | 365 |
2015 | CUTTER OIL COMPANY | 5233 | 441 | 365 |
2016 | CUTTER OIL COMPANY | 3512 | 296 | 365 |
2017 | CUTTER OIL COMPANY | 2744 | 201 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2008 | CUTTER OIL COMPANY | Brine | 1521 | 94 |
2009 | CUTTER OIL COMPANY | Brine | 421 | 365 |
2010 | CUTTER OIL COMPANY | Brine | 345 | 365 |
2011 | CUTTER OIL COMPANY | Brine | 388 | 365 |
2012 | CUTTER OIL COMPANY | Brine | 419 | 366 |
2013 | CUTTER OIL COMPANY | Brine | 308 | 365 |
2014 | CUTTER OIL COMPANY | Brine | 210 | 365 |
2015 | CUTTER OIL COMPANY | Brine | 222 | 365 |
2016 | CUTTER OIL COMPANY | Brine | 191 | 365 |
2017 | CUTTER OIL COMPANY | Brine | 192 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0345861375 | 2015-07-13 | UrbanProduction Wells | No Violations | I inspected this producing well as a follow-up to an earlier Compliance Notice from 05/20/2015. Load-lines and electrical boxes are now locked and secure. Tank lids are sealed and secure. Leakage at the stuffing box and the brine flange have been mitigated and fixed. The noted safety deficiencies have been resolved. The update to the ID signage information is in process. |
0353836138 | 2017-11-28 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection activity. The well and battery are located at the rear portion of an elememtary school property At the time of this inspection, I observed the following: the fittings and connections at the wellhead pump jack system and the battery were secure. The tank lids were closed and secure. The load-lines were secure, plugged and locked. The secondary containment was intact and free from signs of leakage. The enclosure gates were locked and secure. The shared-use access consists of asphalt-paved drive-way and parking for the church. I walked and inspected the areas surrounding the well and battery and found no overt or observable signs of environmental impact. The production reports were current. Bonding and insurance for this owner were current. |
0408502778 | 2013-10-28 | UrbanProduction Wells | No Violations | The producing unit consists of a wellhead with pump jack and above-ground storage tank (AST) battery. The battery is comprised of 2 140-barrel steel production tanks, 1 50-barrel brine tank and separator unit with Dominion metering run. There is also a skid-mounted compressor unit in the wellhead enclosure. Both the wellhead and battery are enclosed in separate board-on-board fences. The gates and load-outs are locked. ID placard and secondary containment are good. Process safety gear (spark arrestor, low-pressure relief valve, carbon filter) is present. No problems noted. |
0616544753 | 2010-01-11 | Production Wells | No Violations | ground cover snow unable to check restoration |
0756848363 | 2010-10-04 | Preliminary Restoration | No Violations | |
0830080503 | 2011-09-07 | UrbanProduction Wells | No Violations | Urban Producing well status check. Well inspected, no violations found. Well is in compliance with 1501-9-9-05. |
0836582663 | 2008-07-03 | Drill / Deepen / Reopen | No Violations | making location |
0840912592 | 2018-10-16 | UrbanProduction Wells | No Violations | I inspected this well location as part of routine inspection and evaluation of current condition following recent change in ownership. At the time of this inspection, I noted the following:. the well was in active production. The enclosure gates were locked and secure. The identification was current and accurate. The load-line valves were plugged and locked. Tank lids were closed and sealed. I walked the areas surrounding the well and battery and found no signs of problems or indications of impact. |
0898063136 | 2008-12-01 | Production Wells | No Violations | violation corrected |
0910082679 | 2008-07-28 | Drill / Deepen / Reopen | No Violations | rig moveing on location |
0982266062 | 2015-01-29 | UrbanProduction Wells | No Violations | I inspected this producing unit as part of routine inspection activity. The wellhead pump jack system enclosure is secure. Valves and connections are secure and free from signs of leakage or problems. At the time of my inspection, the area is covered with several inches of snow. Access to the wellhead and battery are via a dedicated access road which extends south from the parking area from the school. The access road has been plowed and is passable. Valves and connections at the battery are secure. Load-outs are bull-plugged and locked. The enclosure is secure. I did not observe any problems at the time of this inspection. |
1102022466 | 2017-04-28 | UrbanProduction Wells | No Violations | I inspected this producing well location as part of routine inspection activity. At the time of this inspection, I noted the following: a wellhead with pump-jack system and associated tank battery in separate board-on-board enclosures located in the back portion of a larger parcel occupied by a school facility. The individual enclosure gates were locked and secure. Fittings and connections at the wellhead were secure. The pump-jack supports were solid. The stuffing box fitting was secure with no leaking or problems. The bridle attachments were secure. Fittings and connections at the battery were secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment was dry and free from any signs of spills, leaks, or other problems. The access road is comprised of a gravel-paved, dedicated road that enters from the back portion of the parking lot for the school. I walked the areas surrounding the well and battery systems and observed the natural soils and vegetation to be free from signs of leaks, spills, or other adverse impact from the on-going production activity. |
1223044646 | 2008-09-30 | Production Wells | No Violations | Inspector Lowder received a call reporting a wellhead release at the Valley Vista well on Wallings Road in North Royalton. The initial reports were that something had failed and rods had been pushed out of the hole by escaping oil and natural gas. The problem was first noticed by teachers working the nearby playground who reported that they heard a loud noise followed by dust around the well. The school administration notified Cutter who responded with equipment and personnel. Upon arrival they found that five full rods and several pup rods along with the polished rod were out of the hole both inside and outside of the fence and the well was spraying oil/water. The rods were bent and damaged by both the incident and during initial response actions. Cutter shut the remaining valves on the wellhead and a high pressure plug was placed in the tubing. The dust was apparently an oil/water spray, which coated the pumping unit, a majority of the board-on-board fence surrounding the well and was carried by wind to the east and impacted trees and ground cover approximately 100 downwind. The groundcover consisted primarily of recently spread grass seed and straw mulch. When I arrived at approximately 15:20, Cutter personnel were wiping down the pumping unit and fence and removing the impacted mulch. Cutter will have Intrepid Well Service on site in the next few days to pull the downhole pump and tubing (if necessary) and try to determine the cause of the incident. I met on site with Rick Simmers, the North Royalton Fire Chief and the North Royalton Assistant Superintendent and discussed the initial response and future actions that would be taken. |
1241152947 | 2019-05-06 | Production Wells | No Violations | I conducted an inspection of the well and found no violation at well or tank battery.
The following maintenance issue needs to be corrected. Gaps between the top of the dike and bottom of the board on broad fencing around the dike. Fluid has collected within the Dike needs to be removed and disposed of properly. I contacted Ed Cutright (contractor pumper) and he stated the fluid will be pumped out and disposed of and fencing issues it will be put on the repair schedule. |
1269366754 | 2010-01-21 | Production Wells | No Violations | no violation |
1300627136 | 2008-07-22 | Drill / Deepen / Reopen | No Violations | site vist |
1323698362 | 2011-12-08 | UrbanProduction Wells | No Violations | On 12/08/2012, DNR Inspector Richard Skidmore, completed an urban production well inspection status check for DNR Inspector Ray Wallace. The lease road, tank battery, and well head locations are in compliance with 1501:9-9-05. Inspection passed. |
1445722361 | 2015-05-07 | UrbanProduction Wells | Violations Noted | I inspected this well location as part of routine inspection activity. The well is located behind the Valley Vista School. There is an unpaved access road which travels south from the school parking area to a multi-purpose learning area and then to the well. At the time of this inspection, there are no wash-outs or erosional deficits along the access road. The wellhead is comprised of a pump jack unit in a board-on-board enclosure which is locked. The tank battery is comprised of a total of two 100-barrel steel production tanks, one 50-barrel poly brine tank, and mechanical separator. The entry doors are secure and locked. At the time of this inspection, the following maintenance issues were noted: Electrical boxes are not locked. Production tank lids are not latched down as required. The entry point signage is broken. Signage is present but lacking complete information. There is leakage at the stuffing box and oil residue within the wellhead secondary containment which needs cleaned up. An empty 55-gallon drum and chemical pump should be removed if not used. Carbon filters must be periodically evaluated for properly operation. In addition, the following safety issues were noted. Load lines are not locked. Brine is actively leaking from the 2-inch flange at the brine tank. Lightning arrestors are missing from the production tanks. The 8.625-inch casing is not exposed for monitoring as required. These safety issues must be remedied as soon as practicable or by 06/19/2015. Please contact Inspector Stephen Tompkins with questions regarding this Compliance Notice. |
1461610163 | 2016-04-25 | UrbanProduction Wells | No Violations | I inspected this well as a routine status and conditions assessment. At the time of this inspcetion, I observed the following: a wellhead with pump jack system and associated tank battery, in separate board-on-board enclosures. Enclosure gates were locked and secure. Fittings and connections at both the wellhead and battery were secure and free from leakage or othr problems. Load-lines were plugged, locked, and secure. Secondary containment was present and intact at both the wellhead and battery. ID signage was present and accurate. The unpaved access road which extends south and then east from the school parking lot was in good condition. I walked the areas surrounding both the wellhead and battery and did not observe any signs of problems or impact associated with the on-going production activity. |
1988040938 | 2008-07-30 | Drill / Deepen / Reopen | No Violations | cementing surface |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1445722361 | US-OH-112964 | 2015-11-13 | LOCKS | |
1445722361 | US-OH-112965 | 2015-11-13 | Well operation causing pollution and contamination |
For data sources see[9]