If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23125 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.305346192,"lon":-80.78231994,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Bazetta Township | |
Operator Name: BECK ENERGY CORPORATION | |
Well Pad ID: | |
Farm/Lease Name: CHURCH OF WARREN | |
License Status: Producing | |
License Date: 1987-10-22 | |
Spud Date: 1987-11-10 | |
Spud Drilling Contractor: [[EPC [EASTERN PETROLEUM]]] | |
Final Drill Date: 1987-11-14 | |
Well Total Depth: 4560 ft | |
Configuration: Vertical | |
Latitude: 41.305346192 | |
Longitude: -80.78231994 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1987-10-22 | Issued Date 10/22/87 Expired Date 10/21/88 Acres 0100750 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04560 Proposed Drill Depth 04560 |
Original Spud | 1987-11-10 | I.P. GAS EST. |
Completed | 1987-11-14 | I.P. GAS EST. |
Reached Total Depth | 1987-11-14 | I.P. GAS EST. |
Construction Permit Expires | 1988-10-21 | I.P. GAS EST. |
CO | 1989-03-08 | 1888 BECK ENERGY CORP GeoDate 10/22/87 |
Completion Report Received | 1989-05-17 | I.P. GAS EST. |
Record Last Modified | 2017-02-15 | I.P. GAS EST. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4340 | 4445 | 44 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 93588 Gal | 50000 | FRAC:SAND/WATER |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL3315 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0809700181 | 2014-05-13 | UrbanProduction Wells | No Violations | I was on location to perform a status check inspection. I found during my inspection the well was in production. The well was equipped with a plunger lift unit. The tank battery consisted of a 100 barrel production tank, a 50 barrel, poly brine tank, and a separator. A dike surrounded the production tank. An identification sign was posted on the production tank. A bull plug was installed on the load line. There was a 7 day production chart inside the separator. Locked, chain link fences surrounded the production equipment and well. The lease road was in stable condition. The well was placed into production prior to House Bill 278. |
1797365556 | 2016-12-19 | UrbanProduction Wells | No Violations | At the time of my inspection, I found the well in production. The well is equipped with a plunger lift assembly. The gate valve on the tubing is in the open position. A domestic gas supply comes off of the wellhead with an open ball valve and a Big Joe regulator. The diked tank battery has two (2) storage tanks and two (2) separators. An identification sign is posted at the tank battery. The load line is secure with a plug. A chain link fences surround the well and tank battery. The access road is in good repair and shared with permit 2-3544.
The equipment on the site consists of the following:
|
1817228319 | 2018-06-11 | UrbanProduction Wells | No Violations | During this inspection, the well was observed to be equipped with a plunger lift assembly and the gate valve and 2 inch flow line valve were open. Production records were up-to-date. The well was fenced. The tank battery consisted of one 210 BBL tank, one 35 BBL tank and two mechanical separators. Valves on the separators were open. One of the separators had two active domestic lines with regulators. The tank battery was diked and fenced. Legible signage was located at the tank battery and the lease access was stable, and shared with well 2-3544. |
For data sources see[9]