If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23441 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.271216016,"lon":-80.80413233,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Howland Township | |
Operator Name: PIN OAK ENERGY PARTNERS LLC | |
Well Pad ID: | |
Farm/Lease Name: KLPRD UNIT | |
License Status: Producing | |
License Date: 1991-09-30 | |
Spud Date: 1991-12-10 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1991-12-13 | |
Well Total Depth: 4596 ft | |
Configuration: Vertical | |
Latitude: 41.271216016 | |
Longitude: -80.80413233 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1991-09-30 | 2816 P & S ENERGY INC GeoDate 9/30/91 |
Oil and Gas | 1991-09-30 | Issued Date 9/30/91 Expired Date 9/29/92 Acres 0043810 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04596 Proposed Drill Depth 04596 |
Original Spud | 1991-12-10 | |
Completed | 1991-12-13 | |
Reached Total Depth | 1991-12-13 | |
Completion Report Received | 1991-12-23 | |
Construction Permit Expires | 1992-09-29 | |
Change of Owner | 2019-02-26 | Operator changed from 2816, P & S ENERGY INC to 9722, PIN OAK ENERGY PARTNERS LLC |
Record Last Modified | 2019-02-26 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4379 | 4430 | 18 |
1997-06-29 | 4362 | 4440 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 80000 Gal | 80000 | FRAC W/80M GAL H20 & 800 SX SAND |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | P & S ENERGY INC | 0 | 0 | 365 |
1992 | P & S ENERGY INC | 45806 | 887 | 365 |
1993 | P & S ENERGY INC | 31136 | 241 | 365 |
1994 | P & S ENERGY INC | 21206 | 96 | 365 |
1995 | P & S ENERGY INC | 15890 | 110 | 365 |
1996 | P & S ENERGY INC | 12680 | 0 | 365 |
1997 | P & S ENERGY INC | 13561 | 79 | 365 |
1998 | P & S ENERGY INC | 11793 | 89 | 365 |
1999 | P & S ENERGY INC | 10426 | 59 | 330 |
2000 | P & S ENERGY INC | 9052 | 29 | 358 |
2001 | P & S ENERGY INC | 9096 | 0 | 323 |
2002 | P & S ENERGY INC | 7880 | 25 | 365 |
2003 | P & S ENERGY INC | 7719 | 0 | 365 |
2004 | P & S ENERGY INC | 7171 | 14 | 365 |
2005 | P & S ENERGY INC | 7038 | 0 | 365 |
2006 | P & S ENERGY INC | 6880 | 21 | 365 |
2007 | P & S ENERGY INC | 6466 | 0 | 365 |
2008 | P & S ENERGY INC | 6312 | 12 | 365 |
2009 | P & S ENERGY INC | 5960 | 0 | 365 |
2010 | P & S ENERGY INC | 6321 | 0 | 365 |
2011 | P & S ENERGY INC | 5881 | 0 | 365 |
2012 | P & S ENERGY INC | 4818 | 0 | 366 |
2013 | P & S ENERGY INC | 5803 | 27 | 365 |
2014 | P & S ENERGY INC | 5055 | 0 | 365 |
2015 | P & S ENERGY INC | 3756 | 0 | 365 |
2016 | P & S ENERGY INC | 3611 | 0 | 365 |
2017 | P & S ENERGY INC | 3416 | 0 | 365 |
2018 | P & S ENERGY INC | 2955 | 0 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1991 | P & S ENERGY INC | Brine | 1650 | 365 |
1992 | P & S ENERGY INC | Brine | 175 | 365 |
1993 | P & S ENERGY INC | Brine | 50 | 365 |
1994 | P & S ENERGY INC | Brine | 0 | 365 |
1995 | P & S ENERGY INC | Brine | 0 | 365 |
1996 | P & S ENERGY INC | Brine | 0 | 365 |
1997 | P & S ENERGY INC | Brine | 65 | 365 |
1998 | P & S ENERGY INC | Brine | 40 | 365 |
1999 | P & S ENERGY INC | Brine | 0 | 330 |
2000 | P & S ENERGY INC | Brine | 0 | 358 |
2001 | P & S ENERGY INC | Brine | 0 | 323 |
2002 | P & S ENERGY INC | Brine | 0 | 365 |
2003 | P & S ENERGY INC | Brine | 0 | 365 |
2004 | P & S ENERGY INC | Brine | 0 | 365 |
2005 | P & S ENERGY INC | Brine | 0 | 365 |
2006 | P & S ENERGY INC | Brine | 70 | 365 |
2007 | P & S ENERGY INC | Brine | 0 | 365 |
2008 | P & S ENERGY INC | Brine | 60 | 365 |
2009 | P & S ENERGY INC | Brine | 0 | 365 |
2010 | P & S ENERGY INC | Brine | 0 | 365 |
2011 | P & S ENERGY INC | Brine | 0 | 365 |
2012 | P & S ENERGY INC | Brine | 55 | 366 |
2013 | P & S ENERGY INC | Brine | 35 | 365 |
2014 | P & S ENERGY INC | Brine | 0 | 365 |
2015 | P & S ENERGY INC | Brine | 0 | 365 |
2016 | P & S ENERGY INC | Brine | 0 | 365 |
2017 | P & S ENERGY INC | Brine | 0 | 365 |
2018 | P & S ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000013907 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 10/7/93 INSPECTOR KEITH WHITE DATE 10/0719/93 DATA FROM OLD VAX INFO | |
0954893406 | 2013-06-05 | UrbanProduction Wells | No Violations | I performed an inspection as a request from ODNR Hydrologist Kyle Tharp in reference to complaint ID 4344. My inspection found the well in production. The well was equipped with a plunger lift unit and partially surrounded by a chain link fence. The tank battery contained two, 210 barrel production tanks and two, separators. There were plugs on all of the load lines. The tank battery was surrounded by a locked chain link fence. The proper identification was posted at the wellhead and tank battery. There were 7 day production chart in the separators. I noticed no visible spills or leaks within the tank battery, wellhead, or surrounding area. The dike was in good condition and capable of meeting containment requirements. The lease road was in good, working condition with a locked gate at the entrance. The tank battery was shared with permit number 2-3411. This well was placed into production prior to House Bill 278. |
1360157969 | 2013-01-06 | UrbanProduction Wells | No Violations | My inspection found the well equipped with a plunger lift unit. It had the proper identification sign posted. The tank battery was surrounded by a locked chain link fence and the proper dike. It contained two, 210 barrel production tanks and two separators. There were plugs in the load lines and the proper identification sign was posted. The separators had 7 day production charts. The lease road was in good, stable condition. It had a locked gate at the entrance with a metal identification sign. This well shares a tank battery with permit number 2-3441. The production records were up to date on our database. This well was placed into production prior to House Bill 278. |
1959888749 | 2016-07-06 | UrbanProduction Wells | No Violations | At the time of my inspection, I found the well is in production. The well is equipped with a plunger lift assembly. The well is engulfed with overgrown weeds and shrubs. The tank battery has two storage tanks and two separators. A locked chain link fence surrounds the tank battery. An identification sign is posted at the well and tank battery. There is a dike around the tank battery. The load lines are secure with bull plugs. The access road is in good repair. I instructed P & S to cut down the weeds and shrubs around the well.
The equipment on the site consists of the following:
|
For data sources see[9]