Well ID: 34-099-20701 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.943510251,"lon":-80.9767215,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Smith Township | |
Operator Name: DORFMAN PRODUCTION COMPANY | |
Well Pad ID: | |
Farm/Lease Name: COURTNEY HM | |
License Status: Producing | |
License Date: 1976-07-20 | |
Spud Date: 1976-07-29 | |
Spud Drilling Contractor: | |
Final Drill Date: 1976-08-11 | |
Well Total Depth: 5428 ft | |
Configuration: Vertical | |
Latitude: 40.943510251 | |
Longitude: -80.97672150 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1976-07-20 | 180 DORFMAN PRODUCTION CO GeoDate 7/20/76 |
Original Spud | 1976-07-29 | IP. A.F. & TR/GAS |
Completed | 1976-08-11 | IP. A.F. & TR/GAS |
Reached Total Depth | 1976-08-11 | IP. A.F. & TR/GAS |
Record Last Modified | 2013-10-03 | IP. A.F. & TR/GAS |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5224 | 5307 | 28 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 3450 Bbl | 84000 | |||
ACID | 0 | 1000 Gal | 0 |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0439344374 | 2012-02-27 | Production Wells | No Violations | I conducted a status check on this site and found that the well is equipped with a pumping unit and connects to a tank battery that consists of one 210 barrel stock tank, one 100 barrel brine storage tank, one separator, and an earthen dike. The tank battery is shared with permits 0991, 1032, 1196, and 2749. Proper identification was posted and I found no leaks or spills at the well head or tank battery. No violations at this time. |
1396918793 | 2007-11-07 | Production Wells | No Violations | I preformed a random field inspection. GPSd the wellhead and the tank battery for the first time. ID signs were posted. The tank battery was in good shape. I found no violations at this time. |
1397567099 | 2014-04-02 | Production Wells | No Violations | I performed a status check on the above location. The tank battery is equipped with one 210 barrel tank and one 100 barrel tank and one horizontal separator. The well is equipped with a pumpjack with an electric motor. No noted violations at this time. ID signs are posted. |
For data sources see[9]