If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-21447 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.972257296,"lon":-80.96258552,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Goshen Township | |
Operator Name: ENERVEST OPERATING LLC | |
Well Pad ID: | |
Farm/Lease Name: SPENCER L& M | |
License Status: Producing | |
License Date: 1982-04-09 | |
Spud Date: 1982-09-13 | |
Spud Drilling Contractor: ARMSTRONG DRLG | |
Final Drill Date: 1982-09-18 | |
Well Total Depth: 5317 ft | |
Configuration: Vertical | |
Latitude: 40.972257296 | |
Longitude: -80.96258552 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Oil and Gas | 1982-04-09 | Issued Date 4/9/82 Expired Date 10/6/82 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05317 Proposed Drill Depth 05317 |
Original Spud | 1982-09-13 | |
Completed | 1982-09-18 | |
Reached Total Depth | 1982-09-18 | |
Construction Permit Expires | 1982-10-06 | |
CO | 1983-01-17 | 182 BELDEN & BLAKE CO GeoDate 4/9/82 |
Completion Report Received | 1983-02-24 | |
Change of Owner | 2007-04-27 | Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 0 | 0 | |
2006-09-11 | 5117 | 5197 | 22 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 76000 Gal | 50000 | FRAC 76 MG WATER 50M SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL13198 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0373597628 | 2017-02-21 | Production Wells | No Violations | I conducted a status check on this site and found that the well is equipped with a pumping unit with an electric motor. Tank battery consists of one 210 barrel stock tank, and one separator. Proper identification was posted. I found no leaks or spills at the well head or the tank battery. |
0397931452 | 2004-09-09 | Production Wells | No Violations | The tank battery consists of 1-210 bbl storag tank, 1-buried concrete salt water tank, 1-separator and a dike. |
0728800534 | 2012-01-31 | Production Wells | No Violations | I conducted a status check on this site and found that the well is equipped with a pumping unit and connects to a tank battery that consists of one 210 barrel stock tank and one separator. There was no brine storage tank present. The thief hatch was closed and there was a bull plug installed in the draw valve. The dike was free of vegetation and debris. Proper identification was posted. I found no leaks or spills at the well head or the tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time. |
1260304127 | 2007-06-19 | Production Wells | No Violations | I performed a random field inspection. GPSs tank battery and wellhead. I found no violations at this time. |
For data sources see[9]