If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-099-22005 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.985659854,"lon":-80.87703212,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Mahoning | |
Municipality: Goshen Township | |
Operator Name: PIDGEON RHONDA & BARRY | |
Well Pad ID: | |
Farm/Lease Name: PIDGEON | |
License Status: Domestic Well | |
License Date: 2016-04-06 | |
Spud Date: 1985-12-11 | |
Spud Drilling Contractor: PERKINS DRLG | |
Final Drill Date: 1985-12-16 | |
Well Total Depth: 5544 ft | |
Configuration: Vertical | |
Latitude: 40.985659854 | |
Longitude: -80.87703212 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1985-12-03 | 213 LOMAK OPERATING CO GeoDate 12/3/85 |
Oil and Gas | 1985-12-03 | Issued Date 12/3/85 Expired Date 12/3/86 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 05544 Proposed Drill Depth 05544 |
Original Spud | 1985-12-11 | |
Completed | 1985-12-16 | |
Reached Total Depth | 1985-12-16 | |
Completion Report Received | 1986-02-10 | |
Construction Permit Expires | 1986-12-03 | |
CO | 1992-10-27 | 56 BUCKEYE OIL PRODUCING CO GeoDate 12/3/85 |
Change of Owner | 2013-02-07 | Operator changed from 5660, S & S ENERGY CORPORATION to 5050, PIDGEON RHONDA & BARRY |
Record Last Modified | 2017-02-15 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5288 | 5344 | 28 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1200 Bbl | 20000 | FRAC;H2O,SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
000PL12765 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0049498312 | 2007-10-24 | Production Wells | No Violations | I performed a random well inspection. GPSs the tank battery and the well. ID sign was posted. The tank battery was in good shape. There were no violations at this time. |
0493623168 | 2018-01-16 | Production Wells | No Violations | The purpose of my inspection was to conduct a status check inspection on well #2-2005. Northeast District Supervisor Stephen Ochs was present during the inspection. Access to the well was snow covered and passable. The power supply line leading to the well head was lying on the ground in several places leading to the well head. The 8.625 well head was below grade. The 4.5 production casing was equipped with an electric pump jack. Production valves were in the closed position. Gas was leaking from the tubing head. A snow covered earthen dike was present around the production tanks. Equipment on location consisted of two (2) 100 bbl production tanks. Identification posted at the tank battery identified Dorfman Production as the operator. I spoke with owner Barry Pidgeon on 01/23/2017 regarding the well head leak and identification. Mr. Pidgeon stated he would have the leak addressed and identification updated as soon as possible. Mr. Pidgeon agreed to contact me when the work was completed for a follow-up inspection. |
0948296938 | 2006-01-04 | Production Wells | No Violations | The tank battery consists of 1-100 bbl storage tank, 1-separator and a low dike. |
1782827069 | 2018-01-30 | Exempt Well Pre Transfer | No Violations | The purpose of my inspection was to document the status leak repairs on well #2-2005. On 01/24/2018 I received a call from contract operator AJ Strawn to report that the leak observed on my previous inspection was due to a loose well head. Mr. Strawn stated that the leak source was a loose well head and that he had tightened the well head and stopped the leak. At the time of my inspection no leaks were observed. Identification at the tank battery needs corrected to reflect the domestic owner. I will contact Mr. Pidgeon to correct the identification. |
For data sources see[9]