34-075-24781

Well Details

Well ID: 34-075-24781
Loading map...
Country: United States
State: Ohio
County: Holmes
Municipality: Clark Township
Operator Name: SENECA ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: RABER LIZZIE A
License Status: Producing
License Date: 1988-07-29
Spud Date: 1988-09-18
Spud Drilling Contractor: G & H DRLG
Final Drill Date: 1988-09-20
Well Total Depth: 4275 ft
Configuration: Vertical
Latitude: 40.462052767
Longitude: -81.78741446

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1988-07-29 114 SENECA ENERGY CORP GeoDate 7/29/88
Oil and Gas 1988-07-29 Issued Date 7/29/88 Expired Date 7/29/89 Acres 0044000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04275 Proposed Drill Depth 04275
Original Spud 1988-09-18
Completed 1988-09-20
Reached Total Depth 1988-09-20
Completion Report Received 1989-01-05
Construction Permit Expires 1989-07-29
Change of Owner 2008-03-26 Operator changed from 114, SENECA ENERGY CORP to 1586, L L P OIL & GAS CORP
Change of Owner 2012-08-31 Operator changed from 1586, L L P OIL & GAS CORP to 9029, SENECA ENERGY CORPORATION
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4080 4158 0
2006-09-11 4108 4154 7

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 102000 Gal 0 WATER FRAC

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1989 SENECA ENERGY CORP 1678 0 365
1990 SENECA ENERGY CORP 3287 0 365
1991 SENECA ENERGY CORP 540 94 365
1992 SENECA ENERGY CORP 833 0 365
1993 SENECA ENERGY CORP 1894 61 365
1994 SENECA ENERGY CORP 1719 48 365
1995 SENECA ENERGY CORP 1849 0 365
1996 SENECA ENERGY CORP 1351 210 366
1997 SENECA ENERGY CORP 1000 177 365
1998 SENECA ENERGY CORP 779 0 365
1999 SENECA ENERGY CORP 695 0 365
2000 SENECA ENERGY CORP 462 0 365
2001 SENECA ENERGY CORP 334 0 365
2002 SENECA ENERGY CORP 219 37 365
2003 SENECA ENERGY CORP 170 0 365
2004 SENECA ENERGY CORP 190 0 365
2005 SENECA ENERGY CORP 194 0 365
2006 SENECA ENERGY CORP 266 0 365
2007 SENECA ENERGY CORP 325 121 365
2008 LLP GAS AND OIL CORPORATION 285 0 365
2009 LLP GAS AND OIL CORPORATION 284 0 365
2010 LLP GAS AND OIL CORPORATION 257 0 365
2011 LLP GAS AND OIL CORPORATION 198 0 365
2012 LLP GAS AND OIL CORPORATION 399 0 366
2013 SENECA ENERGY CORPORATION 222 0 365
2014 SENECA ENERGY CORPORATION 350 31 365
2015 SENECA ENERGY CORPORATION 350 31 365
2016 SENECA ENERGY CORPORATION 440 0 365
2017 SENECA ENERGY CORPORATION 365 27 365
2018 SENECA ENERGY CORPORATION 361 20 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1989 SENECA ENERGY CORP Brine 0 365
1990 SENECA ENERGY CORP Brine 0 365
1991 SENECA ENERGY CORP Brine 52 365
1992 SENECA ENERGY CORP Brine 0 365
1993 SENECA ENERGY CORP Brine 0 365
1994 SENECA ENERGY CORP Brine 0 365
1995 SENECA ENERGY CORP Brine 0 365
1996 SENECA ENERGY CORP Brine 0 366
1997 SENECA ENERGY CORP Brine 127 365
1998 SENECA ENERGY CORP Brine 0 365
1999 SENECA ENERGY CORP Brine 75 365
2000 SENECA ENERGY CORP Brine 0 365
2001 SENECA ENERGY CORP Brine 125 365
2002 SENECA ENERGY CORP Brine 0 365
2003 SENECA ENERGY CORP Brine 0 365
2004 SENECA ENERGY CORP Brine 0 365
2005 SENECA ENERGY CORP Brine 0 365
2006 SENECA ENERGY CORP Brine 0 365
2007 SENECA ENERGY CORP Brine 80 365
2008 LLP GAS AND OIL CORPORATION Brine 0 365
2009 LLP GAS AND OIL CORPORATION Brine 0 365
2010 LLP GAS AND OIL CORPORATION Brine 0 365
2011 LLP GAS AND OIL CORPORATION Brine 0 365
2012 LLP GAS AND OIL CORPORATION Brine 0 366
2013 SENECA ENERGY CORPORATION Brine 0 365
2014 SENECA ENERGY CORPORATION Brine 23 365
2015 SENECA ENERGY CORPORATION Brine 37 365
2016 SENECA ENERGY CORPORATION Brine 49 365
2017 SENECA ENERGY CORPORATION Brine 0 365
2018 SENECA ENERGY CORPORATION Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
000PL15076 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0584725007 2014-01-06 Production Wells No Violations This is a producing plunger lift well. There were no problems noted at the time of the inspection.
1072724341 2017-03-09 Production Wells No Violations This is a producing plunger lift well. There were no problems noted at the time of the inspection.
1083348364 2012-02-28 Production Wells Violations Noted Producing plunger lift. Oil spill at tank (tank riser broke). Estimate <1 bbl spilled. Contained. Contaminated soil needs removed. Called operator and he will comply. Riser has been repaired.
1364952825 2018-10-12 Production Wells No Violations On the day of my inspection I found, an 8 5/8 inch diameter casing, 4 1/2 inch diameter casing, and 1 1/2 inch diameter tubing, operated by a plunger lift system. The production equipment is made up of one 210 bbl. steel tank, a horizontal, and a recording gauge. The tank is properly identified, and production reporting is up to date.
1668717199 2015-03-03 Production Wells No Violations This is a producing plunger lift well. There were no problems noted at the time of the inspection.
1806032553 2016-03-29 Production Wells No Violations This is a producing plungere lift well. There were no problems noted at the time of the inspection.
1852682185 2012-04-24 Production Wells No Violations The oil contaminated soil and stone were removed and new stone was put inside the dike. NOV satisfied this date.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1083348364 US-OH-101893 2012-02-28 Well operation causing pollution and contamination

For data sources see[9]