34-055-21834

Well Details

Well ID: 34-055-21834
Loading map...
Country: United States
State: Ohio
County: Geauga
Municipality: Chester Township
Operator Name: ALLIANCE PETROLEUM CORPORATION
Well Pad ID:
Farm/Lease Name: HANFORD UNIT
License Status: Producing
License Date: 2006-05-23
Spud Date: 2005-07-06
Spud Drilling Contractor: KILBARGER DRLG
Final Drill Date: 2005-07-17
Well Total Depth: 3840 ft
Configuration: Vertical
Latitude: 41.550317417
Longitude: -81.35973707

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-06-20 Proposed Formations:CLINTON/MEDINA, Issued Date:6/20/2005, Expired Date:6/20/2006 6:00:00 AM, Drilling unit acres:22.8, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2005-07-06 RBDMS Rec
Completed 2005-07-17 RBDMS Rec
Reached Total Depth 2005-07-17 RBDMS Rec
Completion Report Received 2006-02-21 RBDMS Rec
Construction Permit Expires 2006-06-20 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-05-23 3678 3702 38

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 74000 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 ALLIANCE PETROLEUM CORPORATION 2806 0 365
2007 ALLIANCE PETROLEUM CORPORATION 5378 101 365
2008 ALLIANCE PETROLEUM CORPORATION 13596 217 365
2009 ALLIANCE PETROLEUM CORPORATION 13746 97 365
2010 ALLIANCE PETROLEUM CORPORATION 14411 161 365
2011 ALLIANCE PETROLEUM CORPORATION 13347 0 365
2012 ALLIANCE PETROLEUM CORPORATION 17209 151 366
2013 ALLIANCE PETROLEUM CORPORATION 13419 50 365
2014 ALLIANCE PETROLEUM CORPORATION 13200 66 365
2015 ALLIANCE PETROLEUM CORPORATION 12558 36 365
2016 ALLIANCE PETROLEUM CORPORATION 9979 47 365
2017 ALLIANCE PETROLEUM CORPORATION 11678 39 365
2018 ALLIANCE PETROLEUM CORPORATION 11377 34 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2007 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2008 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2009 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2010 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2011 ALLIANCE PETROLEUM CORPORATION Brine 0 365
2012 ALLIANCE PETROLEUM CORPORATION Brine 0 366
2013 ALLIANCE PETROLEUM CORPORATION Brine 78 365
2014 ALLIANCE PETROLEUM CORPORATION Brine 156 365
2015 ALLIANCE PETROLEUM CORPORATION Brine 15 365
2016 ALLIANCE PETROLEUM CORPORATION Brine 80 365
2017 ALLIANCE PETROLEUM CORPORATION Brine 26 365
2018 ALLIANCE PETROLEUM CORPORATION Brine 42 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0144990697 2005-07-07 Drill / Deepen / Reopen No Violations ran 85/8 cement company late also not enough pit room to cement
0190919369 2010-08-23 Production Wells No Violations Well is in good repair. Lease road is stable and covered in vegetation. Identification sign is posted. Identification sign is posted. Site is stable and in good repair.
0361454793 2005-07-14 Drill / Deepen / Reopen No Violations drilling at 2600
0473850390 2013-06-18 UrbanProduction Wells No Violations My inspection found the well to be equipped with a plunger lift unit. The annulus valve was closed. The well and tank battery are in good repair and are surrounded by a chain link fence. The tank battery consists of two 100 BBL production tanks, a 35 BBL poly brine tank, and a mechanical separator. The proper identification is located on the tank battery. The lease road is in stable condition.
0800075462 2017-04-10 UrbanProduction Wells No Violations During this inspection, the well was equipped with a plunger lift assembly and the valves on the wellhead were open. There was a domestic line plumbed off of the 4.5 inch casing with two regulators and a drip bottle. The well was fenced and locked. Production records for this well were up to date. The tank battery consisted of two 100 BBL production tanks, one 25 BBL brine tank and a mechanical separator. Valves were open on the separator and the chart dated 3/28/17 showed production. There was a domestic line off of the mechanical separator with a regulator and four meters. Load line were equipped with flat plugs and locked. The tank battery was diked. Proper, legible signage was located at the well and tank battery and the lease access was stable. No violations observed.
1071333900 2008-05-06 Preliminary Restoration No Violations Final grading and seeding have not been completed on site. Vegetation is not established. There is debris on site, parts of the safety fence, black plastic one section of pipe line. Debris needs removed. Site needs final grading, seeded and mulched. Called Bruce from the company. Landowner was going to complete work, has not. Bruce will get repairs completed next week.
1138761127 2008-10-07 Preliminary Restoration No Violations On site with Supervisor. Reclamation is approved at this time. Site meets 1509 requirements.
1173203024 2007-03-06 Production Wells No Violations Site is snow covered. Well head is fenced and signed. Tank battery is fenced and signed. Two 110BBL and one plastic 35BBL tanks on site. Mechanical separator in tank battery. Lease road stable.
1193921292 2007-11-01 Preliminary Restoration Violations Noted Site has not been seeded and mulched. Affected area around the well head is barren. Moss and a few native species of plants have began to grow. Vegetation cover is less than 20%. This amount of vegetative cover is not sufficient to prevent off site erosion. Called Bruce Close left message to call me regarding site. Slopes to the on the lease road south of the well have rill erosion on them. Lease road is washing out, site has standing water. Site needs limed, fertilized, seeded and mulched. Vegetation needs to be established to prevent erosion.
1222881511 2008-10-01 Preliminary Restoration No Violations Lease road is stable. Operator has done nothing to improve vegetation on site. Operator still has areas of barren soil. Vegetation is native. Areas are holding water. Trees are stockpiled around site. Rill erosion north end needs repaired. NOV not passed at this time.
1875711177 2006-01-13 Production Wells No Violations recevied complaint from Mike Joyce zoning Chester of mud on road( Pear tree lane).

Insected site found no debrie or mud on road. Case closed

1922679114 2005-07-08 Drill / Deepen / Reopen No Violations drilling at 800 equipment problem.
2023366905 2005-07-05 Drill / Deepen / Reopen No Violations Rig move on
2023716302 2005-07-06 Drill / Deepen / Reopen No Violations drilling out of conductor at 50
2111875509 2005-08-30 Completion Testing No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1193921292 US-OH-105117 2007-11-01 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)

For data sources see[9]

References