X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-035-21899

Well Details

Well ID: 34-035-21899
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Mayfield Township
Operator Name: OHIO VALLEY ENERGY SYSTEM CORP
Well Pad ID:
Farm/Lease Name: THORPE
License Status: Producing
License Date: 2006-06-07
Spud Date: 2006-08-30
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-09-08
Well Total Depth: 3435 ft
Configuration: Vertical
Latitude: 41.545119274
Longitude: -81.40713785

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2006-04-14 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:4/14/2006, Expired Date:4/14/2007 6:00:00 AM, Drilling unit acres:20.04, Proposed Well Type:OG, Proposed Well Class:POOL
APP 2006-06-07 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:6/7/2006, Expired Date:6/7/2007 6:00:00 AM, Drilling unit acres:20.4, Proposed Well Type:OG, Proposed Well Class:POOL
Completed 2006-09-08
Reached Total Depth 2006-09-08
Completion Report Received 2006-11-24
Construction Permit Expires 2007-06-07
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2007-01-28 3150 3190 61

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 15 2214 Bbl 60000 1000 GALLONS IC ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEM CORP 9265 54 244
2008 OHIO VALLEY ENERGY SYSTEM CORP 28622 122 365
2009 OHIO VALLEY ENERGY SYSTEM CORP 25293 57 365
2010 OHIO VALLEY ENERGY SYSTEM CORP 50416 121 365
2011 OHIO VALLEY ENERGY SYSTEM CORP 64255 188 365
2012 OHIO VALLEY ENERGY SYSTEM CORP 68107 70 366
2013 OHIO VALLEY ENERGY SYSTEM CORP 50963 58 365
2014 OHIO VALLEY ENERGY SYSTEM CORP 39914 60 365
2015 OHIO VALLEY ENERGY SYSTEM CORP 31974 61 365
2016 OHIO VALLEY ENERGY SYSTEM CORP 28530 0 365
2017 OHIO VALLEY ENERGY SYSTEM CORP 23722 0 365
2018 OHIO VALLEY ENERGY SYSTEM CORP 20482 67 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 OHIO VALLEY ENERGY SYSTEM CORP Brine 100 244
2008 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2009 OHIO VALLEY ENERGY SYSTEM CORP Brine 80 365
2010 OHIO VALLEY ENERGY SYSTEM CORP Brine 130 365
2011 OHIO VALLEY ENERGY SYSTEM CORP Brine 205 365
2012 OHIO VALLEY ENERGY SYSTEM CORP Brine 212 366
2013 OHIO VALLEY ENERGY SYSTEM CORP Brine 80 365
2014 OHIO VALLEY ENERGY SYSTEM CORP Brine 66 365
2015 OHIO VALLEY ENERGY SYSTEM CORP Brine 241 365
2016 OHIO VALLEY ENERGY SYSTEM CORP Brine 0 365
2017 OHIO VALLEY ENERGY SYSTEM CORP Brine 50 365
2018 OHIO VALLEY ENERGY SYSTEM CORP Brine 25 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0226947601 2015-09-22 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well and battery are located in a residential area on the west side of Chagrin River Road. The area immediately surrounding the well is comprised of a small wooded portion of a larger parcel. Access to the well and battery are afforded by an unpaved, dedicated lease road which enters from Racerbrook Drive and travels 300 feet to the unit. At the time of this inspection, the well is in production and records are current. Enclosure gates are locked and secure. Load-lines are locked and secure. Fittings at the wellhead and battery are secure and free from leakage. Battery secondary containment is intact and free from staining or other problems. ID signage is present and accurate. The access road is in good condition and well drained. Areas surrounding the wellhead and battery are free from signs of impact relating to production activity.
0368893701 2007-04-11 Drill / Deepen / Reopen No Violations fencing up waiting on landscaper
0510876155 2017-11-20 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection the wellhead and battery board-on-board enclosures were closed and locked. The load-line valves were secure and locked. Tank lids were closed and secure. Secondary containment as intact and free from signs of release, leaks, or problems. The well was in active production. Production reports were current. Bonding and insurance were active and current. I walked and inspected the areas surrounding the wellhead and battery and found no evidence of impacts from leaks, releases, or degradation to the natural greenscape.
0579678196 2008-08-11 Preliminary Restoration No Violations
0995389010 2006-11-07 Drill / Deepen / Reopen No Violations area graded pits closed.
0997334355 2006-06-05 Drill / Deepen / Reopen No Violations Making location cutting trees to well site
1403108754 2014-06-18 UrbanProduction Wells No Violations I inspected this producing unit as part of regular site check and inspection activity. The well was completed in 11/24/2006. Elements of the well consist of a production wellhead with standard valve assembly and mechanical plunger lift system. The wellhead is located in a closed and locked board-on-board enclosure. The 8.625-inch casing is valved to surface but is not gauged. There are no signs of leakage or problems at the wellhead. The aboveground storage tank battery is located southeast and adjacent to the wellhead. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel poly brine tank, and a horizontal separator. The battery is located in a separate board-on-board enclosure which is gated and locked. The load-outs are bull-plugged and locked. There is process safety equipment in use (carbon filter, low-pressure relief valve, and spark arrestor). The secondary containment at the battery appears well maintained. I did not observe any signs or evidence of leakage, spills, or problems. There is ID signage at the battery and wellhead which are legible and in good condition. The area of the well is generally level with a rapid topographic drop to the south and east. Surface draining appears to be towards an unnamed tributary to the Chagrin River which lies approximately 100 feet to the southeast. I did not observe any signs of gully formation or washouts. Access to the unit is afforded by a dedicated gravel-paved access road which is partially shared with other homes along Racerbrook Drive. The short access road is currently in good condition and free of washout or erosional deficits. Beyond the area cleared for the wellhead and tank battery, the areas surrounding the unit are heavily wooded with one single-family residential home bordering to the northwest, and no other residential strucutres within eyesight.
1415406094 2006-06-06 Drill / Deepen / Reopen No Violations cutting trees making location

For data sources see[9]

References