34-035-22090

Well Details

Well ID: 34-035-22090
Loading map...
Country: United States
State: Ohio
County: Cuyahoga
Municipality: Orange Township
Operator Name: BASS ENERGY CO INC
Well Pad ID:
Farm/Lease Name: PICCIANO UNIT
License Status: Producing
License Date: 2008-12-01
Spud Date: 2008-12-30
Spud Drilling Contractor: CAPSTAR DRILLING
Final Drill Date: 2009-01-08
Well Total Depth: 3810 ft
Configuration: Vertical
Latitude: 41.450182545
Longitude: -81.46123193

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-12-01 Proposed Formations:OHIO SHALE THRU CLINTON, Issued Date:12/1/2008, Expired Date:12/1/2009 6:00:00 AM, Drilling unit acres:25.14, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2009-01-08
Completion Report Received 2009-04-16
Construction Permit Expires 2009-12-01
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2009-06-25 3612 3640 44

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 72310 Gal 40000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2009 BASS ENERGY CO INC 4646 322 273
2010 BASS ENERGY CO INC 5088 312 365
2011 BASS ENERGY CO INC 3274 323 0
2012 BASS ENERGY CO INC 2367 105 366
2013 BASS ENERGY CO INC 1475 126 365
2014 BASS ENERGY CO INC 1231 138 365
2015 BASS ENERGY CO INC 976 119 365
2016 BASS ENERGY CO INC 928 144 365
2017 BASS ENERGY CO INC 790 131 365
2018 BASS ENERGY CO INC 676 95 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2009 BASS ENERGY CO INC Brine 871 273
2010 BASS ENERGY CO INC Brine 544 365
2011 BASS ENERGY CO INC Brine 578
2012 BASS ENERGY CO INC Brine 250 366
2013 BASS ENERGY CO INC Brine 160 365
2014 BASS ENERGY CO INC Brine 40 365
2015 BASS ENERGY CO INC Brine 300 365
2016 BASS ENERGY CO INC Brine 245 365
2017 BASS ENERGY CO INC Brine 347 365
2018 BASS ENERGY CO INC Brine 186 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0100676200 2009-02-05 Drill / Deepen / Reopen No Violations site visit found company dealing with issue truck drive backed into well head bent casing now company is dealing with trying to straighten casing. No violation to company
0867430056 2016-03-09 UrbanProduction Wells No Violations I inspected this well as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with a pump jack system in a board-on-board enclosure. The enclosure gate was locked and secure. Fittings and connections were secure. The surface casing was plumbed to the production system. The tank battery was comprised of one 100-barrel steel production tank, one 50-barrel steel brine tank, and separator in a separate board-on-board enclosure which was locked and secure. The load-line valves were plugged and locked. The tank lids were closed and sealed. The secondary containment was intact. I walked the area around the well and battery. The surrounding area is comprised flat-lying wooded terrain with open, low-lying portions. I did not observe any signs of impact or problems.
0923151374 2009-11-12 Preliminary Restoration No Violations no violation.
0955924718 2009-01-05 Drill / Deepen / Reopen No Violations Drilling at 2370 no violation
1224416880 2014-08-18 UrbanProduction Wells No Violations I inspected this producing unit as part of routine inspection activity. The well was completed in 01/08/2009. The unit is producing and production reports are current. The producing unit is accessed via a dedicated, gravel-paved access road which extends east from the terminus of the current residential driveway. The access road is level, and well drained with no signs of erosional deficits. Elements of the well consist of a production wellhead with standard valve assembly and pump jack system and aboveground storage tank (AST) battery in separate board-on-board enclosures. I observed oily impact from leaking stuffing box fitting around the base of the wellhead. I did not observe any other problems at the wellhead. The battery is comprised of 1 steel 100-barrel production tank, 1 50-barrel steel brine tank, and separator unit. Spacing from well to battery, and spacing of elements within the battery meet regulations. The load-outs are bull-plugged. There is secondary containment at the battery and the interior areas are dry. I did not observe any signs or evidence of leakage, spills, or problems. Unit identification placards are present at both the battery and wellhead and are in good condition. I contacted Bass Energy about the need to mitigate the oily impact around the wellhead and perform maintenance on the leaking stuffing box.
1236187728 2009-02-06 Drill / Deepen / Reopen No Violations on site checked for violation none found. Company has been working on casing because a truck driver backed into casing and bent it company had straighten casing and rods well is ready to be put on line.
1533652354 2018-08-07 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: The well was in active production with active chart record. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of tall grasses and other vegetation, with a short, gravel-paved access road. I did not observe any signs of problems.
1816568852 2009-01-07 Drill / Deepen / Reopen No Violations drilling at 3500 no violation
2125603630 2017-08-10 UrbanProduction Wells No Violations I inspected this well location as part of routine inspection activity. At the time of this inspection, I observed the following: a wellhead with plunger lift system and associated tank battery in separate board-on-board enclosures on a suburban residential property. The enclosure gates were locked. The load line valves were secure. The secondary containment was intact. Fittings and connections at the wellhead and battery were secure. The surrounding areas are comprised of tall grasses and other vegetation, with a short, gravel-paved access road. I did not observe any signs of problems.

For data sources see[9]

References