37-123-41511

Well Details

Well ID: 37-123-41511
Loading map...
Country: United States
State: Pennsylvania
County: Warren
Municipality: Columbus Township
Operator Name: STK INVESTMENTS LLC
Well Pad ID:
Farm/Lease Name: P & N WADE 2
License Status: Active
Spud Date: 1992-12-31
Permit Date: 1992-06-11
Unconventional Well: N
Configuration: Vertical Well
Latitude: 41.955869
Longitude: -79.585101

For data sources see[1][2][3]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1992 0.00 0 0.00 0 0.00 0
1996 EXCO RESOURCES PA INC 441.00 365 0.00 0 0.00 0
1997 EXCO RESOURCES PA INC 215.00 365 0.00 0 0.00 0
1998 EXCO RESOURCES PA INC 17.00 365 0.00 0 0.00 0
1999 0.00 0 0.00 0 0.00 0
2000 0.00 0 0.00 0 0.00 0
2001 0.00 0 0.00 0 0.00 0
2004 0.00 0 0.00 0 0.00 0
2005 0.00 0 0.00 0 0.00 0
2006 0.00 0 0.00 0 0.00 0
2007 0.00 0 0.00 0 0.00 0
2008 0.00 0 0.00 0 0.00 0
2009 0.00 0 0.00 0 0.00 0
2010 0.00 0 0.00 0 0.00 0
2011 0.00 0 0.00 0 0.00 0
2012 0.00 0 0.00 0 0.00 0
2013 0.00 0 0.00 0 0.00 0
2014 0.00 0 0.00 0 0.00 0
2015 0.00 0 0.00 0 0.00 0
2016 0.00 0 0.00 0 0.00 0
2017 0.00 0 0.00 0 0.00 0

For data sources see[4]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1961038 Primary Facility 2011-03-29 Routine/Complete Inspection No Violations Noted
2620901 Primary Facility 2017-07-28 Routine/Complete Inspection Violation(s) Noted
2773628 Primary Facility 2018-09-11 Follow-up Inspection Outstanding Violations - Viols Req'd Status of well unchanged since last inspection dated 07/28/2017. No well tag or sit ID sign posted. 2017 production reports indicate that the well is temporarily not producing and is to be plugged.
2826120 Primary Facility 2019-01-14 Follow-up Inspection Outstanding Violations - Viols Req'd Condition of well has not changed since last inspection dated 09/11/2018. Site identification and well tag have not been installed or posted on well or well location. Surface casing and tubing are shut in. Production casing is shut in at production line, but is open to a regulated 1" line, which indicates possible home use. Submitted production reports have this well listed as "temporarily not producing", since company acquisition in 2012. If well is being utilized for home use gas, it is not being reported on annual production reports. Cannot confirm home use due to unknown locations of residence connections.
761126 Primary Facility 1993-01-20 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2620901 792766 2017-07-28 2017-12-19 OGA3211(G) Administrative
2620901 792767 2017-07-28 2017-12-19 OGA3211(H) Administrative
2773628 827643 2017-07-28 OGA3211(G) Administrative
2773628 827644 2017-07-28 OGA3211(H) Administrative
2826120 838827 2019-01-14 OGA3211(H) Administrative
2826120 838828 2019-01-14 OGA3211(G) Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
792766 360394 ADORD - Administrative Order
792767 360394 ADORD - Administrative Order

For data sources see[5]