{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.921961,"lon":-80.218236,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Greene | |
Municipality: Franklin Township | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148450 | |
Farm/Lease Name: GROOMS UNIT 9H | |
License Status: Active | |
Spud Date: 2011-08-28 | |
Permit Date: 2011-03-14 | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Latitude: 39.921961 | |
Longitude: -80.218236 |
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-09-21 | 2012-09-21 | 6491.00 | 4,307,696.0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00001000 | |
Carbohydrates | 95.00 | 0.00009000 | ||||||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00303000 | ||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
Biocide EC 6116A | Nalco | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00748000 | ||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00125000 | |||||
Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | |||||
Proppant (lbs) | Proppant | 8.71 | 9.62 | |||||
Clean Volume (gals) | Carrier/Base Fluid | 91.29 | 100.00 | |||||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00688000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.30 | |||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00740000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | ATLAS RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 1,490,081.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 777,181.00 | 365 | 0.00 | 0 | 133.76 | 184 |
2015 | CHEVRON APPALACHIA LLC | 570,798.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 452,278.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 323,929.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 239,631.00 | 273 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 84,845.00 | 90 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|
2012-S01 | Drilling Fluid Waste (in Barrels) | 1,760.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 1,170.02 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012-S02 | Fracing Fluid Waste (in Barrels) | 3,120.15 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Fracing Fluid Waste (in Barrels) | 17.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013-S01 | Fracing Fluid Waste (in Barrels) | 1,835.63 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S01 | Produced Fluid (in Barrels) | 1,233.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Fracing Fluid Waste (in Barrels) | 536.25 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2013-S02 | Fracing Fluid Waste (in Barrels) | 2,182.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013-S02 | Fracturing Fluid Waste (in Tons) | 27.71 Tons | LANDFILL | 073 114 654 |
2013-S02 | Produced Fluid (in Barrels) | 339.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S01 | Fracturing Fluid Waste (in Tons) | 2.22 Tons | LANDFILL | 100172 |
2014-S01 | Produced Fluid (in Barrels) | 8.75 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-S01 | Produced Fluid (in Barrels) | 257.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S01 | Produced Fluid (in Barrels) | 973.25 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014-S02 | Produced Fluid (in Barrels) | 15.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014-S02 | Produced Fluid (in Barrels) | 133.75 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2014-S02 | Produced Fluid (in Barrels) | 616.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S01 | Produced Fluid (in Barrels) | 680.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015-S02 | Produced Fluid (in Barrels) | 618.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S01 | Produced Fluid (in Barrels) RWC 802 | 666.19 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 444.13 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016-S02 | Produced Fluid (in Barrels) RWC 802 | 90.38 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017-M01 | Produced Fluid (in Barrels) RWC 802 | 75.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M01 | Soil Contaminated by Oil & Gas Related Spills (in Tons) RWC 811 | 0.03 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017-M02 | Produced Fluid (in Barrels) RWC 802 | 62.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 30.08 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M03 | Produced Fluid (in Barrels) RWC 802 | 30.63 Bbl | REUSE (AT WELL PAD) | |
2017-M04 | Produced Fluid (in Barrels) RWC 802 | 15.63 Bbl | REUSE (AT WELL PAD) | |
2017-M05 | Produced Fluid (in Barrels) RWC 802 | 577.50 Bbl | REUSE (AT WELL PAD) | |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 43.75 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 15.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M06 | Produced Fluid (in Barrels) RWC 802 | 15.00 Bbl | REUSE (AT WELL PAD) | |
2017-M07 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 11.25 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 13.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M08 | Produced Fluid (in Barrels) RWC 802 | 12.50 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2017-M09 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2017-M10 | Produced Fluid (in Barrels) RWC 802 | 41.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 13.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017-M11 | Produced Fluid (in Barrels) RWC 802 | 39.38 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 15.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2017-M12 | Produced Fluid (in Barrels) RWC 802 | 41.75 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 42.50 Bbl | REUSE (AT WELL PAD) | |
2018-M02 | Produced Fluid (in Barrels) RWC 802 | 13.13 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 26.88 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE (AT WELL PAD) | |
2018-M03 | Produced Fluid (in Barrels) RWC 802 | 14.13 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018-M04 | Produced Fluid (in Barrels) RWC 802 | 54.38 Bbl | REUSE (AT WELL PAD) | |
2018-M05 | Produced Fluid (in Barrels) RWC 802 | 27.50 Bbl | REUSE (AT WELL PAD) | |
2018-M06 | Produced Fluid (in Barrels) RWC 802 | 55.63 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 28.13 Bbl | REUSE (AT WELL PAD) | |
2018-M07 | Produced Fluid (in Barrels) RWC 802 | 13.75 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M08 | Produced Fluid (in Barrels) RWC 802 | 67.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M09 | Produced Fluid (in Barrels) RWC 802 | 40.63 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M11 | Produced Fluid (in Barrels) RWC 802 | 54.38 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 12.50 Bbl | REUSE (AT WELL PAD) | |
2018-M12 | Produced Fluid (in Barrels) RWC 802 | 81.88 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019-M01 | Produced Fluid (in Barrels) RWC 802 | 87.50 Bbl | REUSE (AT WELL PAD) | |
2019-M02 | Produced Fluid (in Barrels) RWC 802 | 57.50 Bbl | REUSE (AT WELL PAD) | |
2019-M03 | Produced Fluid (in Barrels) RWC 802 | 43.75 Bbl | REUSE (AT WELL PAD) |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2006244 | Primary Facility | 2011-09-21 | Drilling/Alteration | No Violations Noted | CONDUCTOR IS SET AT 100'. NO OTHER DRILLING. |
2027571 | Primary Facility | 2011-09-13 | Routine/Complete Inspection | No Violations Noted | The Department was at the above referenced Marcellus Well to conduct a Routine Inspection. The operator is finishing up construction of the pad and lining the pits. The Department reviewed the E/S Plan on site. The E/S controls appear to be in good condition. The Operator is currently adding E/S controls to make sure all the sediment stays on site. Temporary stabilization has been obtained on this site. Grass is beginning to grow on the fill slopes. |
2035020 | Primary Facility | 2012-01-09 | Drilling/Alteration | No Violations Noted | WELL DRILLED TO KOP. WILL BE COMPLETED WITH A BIGGER RIG. |
2051389 | Primary Facility | 2012-03-13 | Drilling/Alteration | No Violations Noted | Patterson 334 drilling for Chevron.Rig had just skidded over getting ready to start driling Grooms 9-H.Site in good condition. |
2051462 | Primary Facility | 2012-03-13 | Drilling/Alteration | No Violations Noted | |
2108321 | Primary Facility | 2012-09-25 | Administrative/File Review | In Compliance with Policy | The Department received a spill notification from the Operator on 9/25/12. 50 gallons of re-use water was spilled to the ground on secondary containment. The Operator vacuumed up the re-use water and disposed. The Department did not conduct a site inspection. The Operator is in compliance with the spill policy. |
2449064 | Primary Facility | 2016-01-09 | Routine/Partial Inspection | No Violations Noted | On 01/09/16 at approximately 0800 hours I conducted a routine partial inspection of the Grooms Unit. The Act 9 sign was in place and all required documents were present at the site. I met with Nick Staffieri of Chevron to discuss changes at the site.
One of the forebays on the site (#3) was moved within the same drainage area as proposed, but without Departmental approval. This is a violation of 102.5(m)(4). It is recommended that Chevron submit for a minor modification to reflect current conditions at the site. |
2636961 | Primary Facility | 2017-09-15 | Site Restoration | No Violations Noted | A site restoration inspection was conducted in response to an NOT submittal by Chevron. The Act 9 sign was in place and all required documents were present at the site. The site was well vegetated and meets and exceeds 70% uniform vegetative cover. There were no signs of erosion observed at the time of inspection. The production equipment appeared to be in good condition. The site meets the requirements for permit termination. The NOT is approved. |