X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-005-23073

Well Details

Well ID: 34-005-23073
Loading map...
Country: United States
State: Ohio
County: Ashland
Municipality: Perry Township
Operator Name: DEEP RESOURCES LLC
Well Pad ID:
Farm/Lease Name: GORTNER ROBERT & PAULINE
License Status: Active Injection
License Date: 1976-11-19
Spud Date: 1976-11-17
Spud Drilling Contractor: M&G OIL CO.
Final Drill Date: 1976-12-23
Well Total Depth: 750 ft
Configuration: Vertical
Latitude: 40.892385880
Longitude: -82.14978513

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1976-11-17 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY
CO 1976-11-19 133 QUAKER STATE OIL REF CORP GeoDate 11/19/76
Enhanced Recovery 1976-11-19 Issued Date 11/19/76 Expired Date Acres 0000000 Tool Type RTAF Proposed Formation BEDFORD Proposed Depth 00000 Proposed Drill Depth 00000
Completed 1976-12-23 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY
Reached Total Depth 1976-12-23 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY
Annulus Pressure Monitoring Approved 1991-01-29 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY
CO 1995-10-18 182 BELDEN & BLAKE CO GeoDate 11/19/76
Last Compliance Report 1999-10-18 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY
Change of Owner 2002-02-07 Operator changed from 182, BELDEN & BLAKE CORPORATION to 2491, MILLER ROY/RA MILLER ENER
Change of Owner 2008-04-24 Operator changed from 2491, MILLER ROY/RA MILLER ENER to 8227, DEEP RESOURCES LLC
Record Last Modified 2017-10-19 RE-ISS. 1-14-76, RE-ISS 2-5-75, R.I., R.L. & SEC. RECY 11-24-76 I.P. NONE RPT. CLASS=SEC. RCY

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2000-05-22 554 633 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
NITR 0 155 Qts 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC 0 133 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2007 DEEP RESOURCES LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0016024222 2009-04-23 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0097905584 2016-04-19 Enhanced Recovery Project No Violations 34005230730000
0136021697 2012-11-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0249697884 2018-01-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0263056654 2013-05-22 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0281563907 2007-03-08 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0295924195 2011-11-17 Enhanced Recovery Project No Violations Inspect well.
0320281450 2008-03-25 Enhanced Recovery Project No Violations Annulus and injection pressure test.
0328599566 2016-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0333308840 2018-04-23 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0362387366 2014-10-28 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0372631146 2014-03-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0374961600 2009-10-20 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0410427451 2016-01-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Retest wellhead. Fittings have thawed out after freezing due to cold weather.
0416895507 2015-09-24 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0436891859 2016-01-05 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Annulus fitting was frozen due to cold weather.
0454591015 2007-10-12 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0508208996 2017-10-19 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0561449951 2010-11-26 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0567752159 2013-03-04 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0574979148 2006-01-25 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0588131007 2018-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
0590489216 2014-07-17 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Tubing has rusted and pvc liner is showing.
0622135591 2008-12-03 Enhanced Recovery Project No Violations Injection and annulus pressure test.
0679716486 2003-11-13 Enhanced Recovery Project No Violations
0687358839 2013-10-29 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1075224583 2017-04-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1087757301 2015-09-28 Enhanced Recovery Project No Violations Inspect well at request of operator. Well head fittings have been replaced and are not leaking.
1101320905 2004-11-18 Enhanced Recovery Project No Violations Injection pressure test.
1116515181 2005-05-19 Enhanced Recovery Project No Violations Injection well test. Update GPS readings.
1166166323 2004-04-22 Enhanced Recovery Project No Violations Injection pressure test.
1269644223 2015-09-08 Work Over Reconditioning No Violations Well head tubing completely rusted. The packer was unseated using a spear because the 5 foot pup-joint was completely deteriorated at the surface. The tubing string and packer were removed from the well. A new parmaco type packer was installed on the 18 existing lined joints of tubing.
1291448997 2011-07-12 Enhanced Recovery Project No Violations inspect well.
1320688116 2012-05-31 Enhanced Recovery Project No Violations Inspect Well. Line leak in well head box.
1441828726 2015-09-09 Work Over Reconditioning No Violations The operator located a below grade flow line leak near the well head. The leak occurred at the change over from the main fiberglass flow line to the steel line connected to the well head. This flow line was replaced during this workover. The five foot internal coated pup joint at the top of the injection tubing string was completely detreated and the internal coating was maintaining integrity. Replacement connections required the packer and tubing be removed. The compression packer was released and the tubing and packer was removed from the well. A new parmaco type tension packer was installed with the existing 18 joints of lined tubing. A replacement pup-joint of tubing was not utilized. Fresh water was circulated, the packer was set, and pressured up to 380 psi. The initial attempt at holding pressure failed due to air bubble trapped in the annulus. The air was bled off the annulus and then re-pressurized to 380 psi. The pressure loss was less than two percent and was within the margin of allowed loss. The test passed. The well head was reconstructed and well put back into injection production.
1502727530 2017-08-09 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1559981971 2012-03-07 Enhanced Recovery Project No Violations Inspect Well. Injector valve is plugged off. No injector reading collected.
1700013113 2006-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1740390648 2010-04-05 Enhanced Recovery Project No Violations Injection and annulus pressure test.
1797069120 2012-09-20 Enhanced Recovery Project No Violations Inspect Well. Site ok.
1817412382 2017-01-06 Enhanced Recovery Project Violations Noted Inspect well for integrity and pressure. The annulus has equalized with the tubing. Released partial pressure on the annulus, subsequently the pressure increased to tubing pressure. The operator has been notified and will schedule the service of the well. The operator shut the well in.
1890160936 2016-07-06 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1910242530 2015-10-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. The well head is in excellent condition. The operator was notified the well is shut in. The operator subsequently opened valve and put well back into production.
1946652964 2015-05-13 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
1970481400 2006-12-14 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2021379314 2011-04-13 Enhanced Recovery Project No Violations Injection and annulus pressure test.
2029134855 2018-10-12 Enhanced Recovery Project No Violations Inspect well for integrity and pressure.
2121187123 2014-05-27 Enhanced Recovery Project No Violations Inspect well for integrity and pressure. Steel tubing at well head is rusted away and the PVC liner is visible. Well is holding pressure.
2143989524 2017-04-25 Enhanced Recovery Project No Violations Current site activities on this date include releasing the packer pulling the packer up six inches, reset the packer and pressure test annulus at 530 psi for 30 minutes with no pressure loss by the operator. The packer was then released and circulate with 225 gallons of fresh water with inhibitor, witnessed by the Inspector. The packer was set at 449.8 feet two inches above 2015 depth; annulus pressured to 480 psi and tested. Pressure loss exceeded margin of error. The packer was then pulled up four inches to set at 449.5 feet below grade. The annulus was pressured up to 488 psi and tested for 15 minutes with 13 pounds of loss. The pressure loss was less than three percent and was within the allowable margin. The test passed. The well head was reconstructed and well put back into operation. The Compliance notice of January 6, 2017 was resolved.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1817412382 US-OH-118149 2017-05-22 9-5-10(H) Mechanical failure/contamination

For data sources see[9]

References