{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.265040598,"lon":-80.5436103,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Brookfield Township | |
Operator Name: VORTEX ENERGY LLC | |
Well Pad ID: | |
Farm/Lease Name: MOYER | |
License Status: Producing | |
License Date: 1980-12-18 | |
Spud Date: 1982-01-19 | |
Spud Drilling Contractor: | |
Final Drill Date: 1982-01-26 | |
Well Total Depth: 5169 ft | |
Configuration: Vertical | |
Latitude: 41.265040598 | |
Longitude: -80.54361030 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1980-12-18 | 54 TITAN ENERGY CORP GeoDate 12/18/80 |
Oil and Gas | 1980-12-18 | Issued Date 12/18/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000 |
Original Spud | 1982-01-19 | |
Completed | 1982-01-26 | |
Reached Total Depth | 1982-01-26 | |
Completion Report Received | 1982-04-13 | |
Change of Owner | 1998-01-26 | Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET |
Change of Owner | 2017-04-13 | Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC |
Record Last Modified | 2017-04-13 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4947 | 5036 | 23 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
N2 | 0 | 227900 | 0 | SCF N2 | ||
H2O | 0 | 59160 Gal | 72000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TITAN ENERGY CORP | 19981 | 114 | 0 |
1985 | TITAN ENERGY CORP | 14179 | 0 | 365 |
1986 | TITAN ENERGY CORP | 10685 | 57 | 365 |
1987 | TITAN ENERGY CORP | 8041 | 0 | 365 |
1988 | TITAN ENERGY CORP | 8342 | 72 | 365 |
1989 | TITAN ENERGY CORP | 8347 | 34 | 365 |
1990 | TITAN ENERGY CORP | 6264 | 0 | 365 |
1991 | TITAN ENERGY CORP | 2900 | 0 | 365 |
1992 | TITAN ENERGY CORP | 4219 | 0 | 365 |
1993 | TITAN ENERGY CORP | 4462 | 0 | 365 |
1994 | TITAN ENERGY CORP | 2290 | 65 | 365 |
1997 | TITAN ENERGY CORP | 3657 | 45 | 245 |
2000 | BIG SKY ENERGY INC | 4745 | 0 | 365 |
2001 | BIG SKY ENERGY INC | 4837 | 0 | 365 |
2002 | BIG SKY ENERGY INC | 5937 | 0 | 365 |
2003 | BIG SKY ENERGY INC | 2897 | 0 | 365 |
2004 | BIG SKY ENERGY INC | 2255 | 0 | 365 |
2005 | BIG SKY ENERGY INC | 2487 | 29 | 365 |
2006 | BIG SKY ENERGY INC | 2535 | 0 | 365 |
2007 | BIG SKY ENERGY INC | 3527 | 0 | 365 |
2008 | BIG SKY ENERGY INC | 3256 | 0 | 365 |
2009 | BIG SKY ENERGY INC | 2473 | 0 | 365 |
2010 | BIG SKY ENERGY INC | 2258 | 0 | 365 |
2011 | BIG SKY ENERGY INC | 1709 | 0 | 365 |
2012 | BIG SKY ENERGY INC | 2422 | 0 | 366 |
2013 | BIG SKY ENERGY INC | 3015 | 0 | 365 |
2014 | BIG SKY ENERGY INC | 2554 | 0 | 365 |
2016 | BIG SKY ENERGY INC | 0 | 0 | 98 |
2017 | BIG SKY ENERGY INC | 0 | 0 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TITAN ENERGY CORP | Brine | 0 | 0 |
1985 | TITAN ENERGY CORP | Brine | 0 | 365 |
1986 | TITAN ENERGY CORP | Brine | 0 | 365 |
1987 | TITAN ENERGY CORP | Brine | 0 | 365 |
1988 | TITAN ENERGY CORP | Brine | 0 | 365 |
1989 | TITAN ENERGY CORP | Brine | 0 | 365 |
1990 | TITAN ENERGY CORP | Brine | 0 | 365 |
1991 | TITAN ENERGY CORP | Brine | 0 | 365 |
1992 | TITAN ENERGY CORP | Brine | 0 | 365 |
1993 | TITAN ENERGY CORP | Brine | 0 | 365 |
1994 | TITAN ENERGY CORP | Brine | 0 | 365 |
1997 | TITAN ENERGY CORP | Brine | 245 | |
2000 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2001 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2002 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2003 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2004 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2005 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2006 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2007 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2008 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2009 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2010 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2011 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2012 | BIG SKY ENERGY INC | Brine | 0 | 366 |
2013 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2014 | BIG SKY ENERGY INC | Brine | 0 | 365 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0000PL4089 | Preliminary Restoration | No Violations | Preliminary Restoration done information from Data Point | |
0790678449 | 2016-04-19 | Production Wells | Violations Noted | |
1910390816 | 2016-09-07 | UrbanProduction Wells | No Violations | I was on location to assess compliance notice # - |
2003995130 | 2014-12-17 | UrbanProduction Wells | No Violations | I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. A domestic gas line came off of the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and a separator. A dike surrounded the tanks. An identification sign was properly posted. There was a plug on the load lines for the two tanks. There was a production chart inside the separator dated 12/15. The lease road was in stable condition with a closed gate at the entrance. The well was placed into production prior to House Bill 278. |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0790678449 | US-OH-129003 | 2016-06-14 | Well operation causing pollution and contamination |