X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-163-20697

Well Details

Well ID: 34-163-20697
Loading map...
Country: United States
State: Ohio
County: Vinton
Municipality: Knox Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: GRIM A PAUL
License Status: Final Restoration
License Date: 2007-08-30
Spud Date: 1983-07-06
Spud Drilling Contractor: GRIM DRILLING
Final Drill Date: 1983-07-12
Well Total Depth: 1350 ft
Configuration: Vertical
Latitude: 39.221683209
Longitude: -82.31574816

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-07-05 566 GRIM PAUL A GeoDate 7/5/83
Oil and Gas 1983-07-05 Issued Date 7/5/83 Expired Date 1/1/84 Acres 0020000 Tool Type CT Proposed Formation BEREA Proposed Depth 01350 Proposed Drill Depth 01350
Original Spud 1983-07-06 R.I. 7-9-83
Completed 1983-07-12 R.I. 7-9-83
Reached Total Depth 1983-07-12 R.I. 7-9-83
CO 1983-07-30 566 GRIM PAUL A GeoDate 12/31/81
Completion Report Received 1985-03-04 R.I. 7-9-83
Change of Owner 2001-11-21 Operator changed from 566, GRIM PAUL A to 5755, CHIEFTAIN ENERGY CORP.
APP 2007-08-30 Proposed Formations:BEREA, Issued Date:8/30/2007, Expired Date:8/29/2008 6:00:00 AM, Drilling unit acres:0, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2008-04-25 R.I. 7-9-83
Construction Permit Expires 2008-08-29 R.I. 7-9-83
Record Last Modified 2017-02-15 R.I. 7-9-83

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1253 1260 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GRIM PAUL A 0 169 365
1989 GRIM PAUL A 0 68 365
1990 GRIM PAUL A 0 526 365
1991 GRIM PAUL A 0 180 365
1992 GRIM PAUL A 0 261 365
1993 GRIM PAUL A 0 107 365
1994 GRIM PAUL A 0 90 365
1995 GRIM PAUL A 0 0 365
1996 GRIM PAUL A 0 79 365
1997 GRIM PAUL A 0 0 365
1998 GRIM PAUL A 80 0 365
1999 GRIM PAUL A 0 0 365
2000 GRIM PAUL A 0 0 365
2001 GRIM PAUL A 0 0 365
2002 HOCKING HILLS ENERGY AND WELL 0 0 0
2003 HOCKING HILLS ENERGY AND WELL 0 0 0
2004 HOCKING HILLS ENERGY AND WELL 0 0 0
2005 HOCKING HILLS ENERGY AND WELL 0 0 0
2006 HOCKING HILLS ENERGY AND WELL 0 0 0
2007 HOCKING HILLS ENERGY AND WELL 0 0 365
2008 HOCKING HILLS ENERGY AND WELL 0 0 116

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GRIM PAUL A Brine 0 365
1989 GRIM PAUL A Brine 791 365
1990 GRIM PAUL A Brine 1672 365
1991 GRIM PAUL A Brine 2112 365
1992 GRIM PAUL A Brine 1325 365
1993 GRIM PAUL A Brine 668 365
1994 GRIM PAUL A Brine 350 365
1995 GRIM PAUL A Brine 0 365
1996 GRIM PAUL A Brine 320 365
1997 GRIM PAUL A Brine 0 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 15 365
2000 GRIM PAUL A Brine 30 365
2001 GRIM PAUL A Brine 0 365
2002 HOCKING HILLS ENERGY AND WELL Brine 0 0
2003 HOCKING HILLS ENERGY AND WELL Brine 0 0
2004 HOCKING HILLS ENERGY AND WELL Brine 0 0
2005 HOCKING HILLS ENERGY AND WELL Brine 0 0
2006 HOCKING HILLS ENERGY AND WELL Brine 0 0
2007 HOCKING HILLS ENERGY AND WELL Brine 0 365
2008 HOCKING HILLS ENERGY AND WELL Brine 0 116

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL2312 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0131272634 2002-08-20 Annular Disposal No Violations Follow-up on NOV, Non-Complinace, no ID at well head and well produces into a common tank battery.
0277434300 2007-11-29 Production Wells No Violations A follow-up inspection revealed non-compliance. Records indicate that the last year of production was 1998. A Chiefs Order will be requested.
0322578914 2009-01-15 Final Restoration Violations Noted An inspection revealed that the final restoration does not meet. The company has failed to respond to verbal notification.
0325617000 2004-10-07 Annular Disposal No Violations Follow-up on NOV, non-compliance, violations not corrected, well still idle, spoke with Doug Kitchen on the phone, he is hoping Paul Grim will take over well.
0359961474 2007-08-10 Administrative Inspection No Violations An administrative inspection was conducted with Mr. Doug Kitchen. Mr. Kitchen states that a plugging application has been submited for this well.
0422680338 2004-05-19 Annular Disposal Violations Noted An inspection of the well revealed the well appears to be idle, according to production records no production in the past 5 years.
0507549206 2007-02-23 Production Wells No Violations Met with Doug Kitchen to discuss violations. Mr. Kitchen was instructed to plug or produce this well.
0571048882 2008-11-03 Final Restoration Violations Noted An inspection revealed that the final restoration does not meet. A 100 bbl tank remains at top of hill and will need to be removed. Chieftain Energy was informed of the inspection results.
0716037944 2005-02-17 Annular Disposal No Violations Follow-up NOV, Non-Compliance, well is not producing in commercial quantities. Have explained this to Doug Kitchen, will need proof of production, such as run tickets from oil sales and or gas sales. To date have not received proof.
0745638513 2009-06-29 Final Restoration No Violations A follow-up inspection revealed non-compliance.
0831776248 2007-02-12 Production Wells Violations Noted An inspection conducted on 2/12/2007 revealed that this well is idle and incapable of producing. There are no production tanks and the pump jack has been removed from well. Also noted was that identification is missing. Mr. Doug Kitchen was informed of the inspection results on 2/15/2007.
0949726821 2009-06-24 Final Restoration No Violations A follow-up inspection revealed non-compliance.
1174972735 2004-09-28 Annular Disposal No Violations Met with Doug Kitchen and Joe Hoerst, Doug said work was not done, at this time have no plans to plug or produce well.
1235765935 2009-02-11 Final Restoration No Violations A follow-up inspection revealed non-compliance.
1269i78056 2002-02-14 Annular Disposal No Violations An inspection of the well revealed No ID at the well, inspecting the tank battery, oil and oily soil in and around the dike, the dike and tank by the shop has oil standing in it. Dike does nt meet SPCC requirements. Need to clean up all oily soil at all 3 tank sites, build dikes to meet SPCC requirements. ID well and tank battery properly.
1269i97158 2002-04-15 Annular Disposal No Violations Follow-up on NOV, Non-Compliance, company has not cleaned up oily soil around the tanks, put ID on the well or tanks, rebuilt a dike around the well to meet SPCC requirements.
1394878038 2005-01-05 Annular Disposal No Violations Follow-up on NOV, In-Compliance
1622854488 2009-07-08 Final Restoration No Violations An inspection revealed that the Final Restoration meets requirements. It was noted that the well location is now missing a longitude coordinate and will need to be corrected in RBDMS.
1808207084 2008-04-25 Plug / Plug Back No Violations Swab tools. Washed clay to the surface.
1825076086 2008-01-02 Administrative Inspection No Violations Meeting with Mr. Doug Kitchen and Mr. Joe Hoerst regarding Chiefs Order. Mr. Kitchen agreed to plug this well within 90 days.
1924846071 2008-04-29 Plug / Plug Back No Violations Met with Chietain Energy at the well site. The well has been plugged and pit closed. Clay stayed at the surface. ID plate not observed.
1953056618 2002-02-14 Annular Disposal Violations Noted FOLLOW UP TO NOV # 1269i780 An inspection of the well revealed No ID at the well, inspecting the tank battery, oil and oily soil in and around the dike, the dike and tank by the shop has oil standing in it. Dike does nt meet SPCC requirements. Need to clean up all oily soil at all
2027948874 2008-04-24 Plug / Plug Back No Violations Checked on plugging. Witnessed company tag bottom of well.
2052628780 2009-07-08 Final Restoration No Violations A follow-up inspection revealed that the Final Restoration meets 1509 ORC.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0322578914 US-OH-123374 2009-01-27 Failure to remove production equip. within 6 mos. REPLACE
0422680338 US-OH-124501 2004-05-24 Well shall be plugged
0571048882 US-OH-126414 2008-11-20 Failure to remove production equip. within 6 mos. REPLACE
0831776248 US-OH-129477 2007-02-26 Failure to legibly identify well
0831776248 US-OH-129478 2007-02-26 Well shall be plugged
1953056618 US-OH-119699 2002-02-14 Well operation causing pollution and contamination
1953056618 US-OH-119700 2002-02-14 Well not equipped to prevent escape of oil and/or gas
1953056618 US-OH-119701 2002-02-14 Failure to legibly identify well
1953056618 US-OH-119702 2002-02-14 No SPCC dike/or failure to keep dike free of water or oil
1953056618 US-OH-119703 2002-02-14 Failure to keep SPCC dike/pit free of brine and other wastes

For data sources see[9]

References