X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-073-22024

Well Details

Well ID: 34-073-22024
Loading map...
Country: United States
State: Ohio
County: Hocking
Municipality: Green Township
Operator Name: HOCKING HILLS ENERGY AND WELL
Well Pad ID:
Farm/Lease Name: TROWBRIDGE HOWARD C
License Status: Producing
License Date: 1977-12-22
Spud Date: 1977-12-24
Spud Drilling Contractor:
Final Drill Date: 1978-02-22
Well Total Depth: 2766 ft
Configuration: Vertical
Latitude: 39.520765741
Longitude: -82.38027365

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1977-12-24
Completed 1978-02-22
Reached Total Depth 1978-02-22
Change of Owner 2018-09-27 Operator changed from 566, GRIM PAUL A to 5755, HOCKING HILLS ENERGY AND WELL SERVICE LLC
Record Last Modified 2018-09-27

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 420000 Gal 20000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 GRIM PAUL A 1494 795 365
1985 GRIM PAUL A 533 541 365
1986 GRIM PAUL A 0 698 365
1987 GRIM PAUL A 0 393 365
1988 GRIM PAUL A 0 414 365
1989 GRIM PAUL A 0 273 365
1990 GRIM PAUL A 0 368 365
1991 GRIM PAUL A 0 249 365
1992 GRIM PAUL A 0 272 365
1993 GRIM PAUL A 0 194 365
1994 GRIM PAUL A 0 223 365
1995 GRIM PAUL A 0 168 365
1996 GRIM PAUL A 0 61 365
1997 GRIM PAUL A 0 0 365
1998 GRIM PAUL A 0 0 365
1999 GRIM PAUL A 0 0 365
2000 GRIM PAUL A 0 90 365
2001 GRIM PAUL A 0 22 365
2002 GRIM PAUL A 0 0 365
2003 GRIM PAUL A 0 0 365
2004 GRIM PAUL A 0 20 365
2005 GRIM PAUL A 0 0 365
2008 GRIM PAUL A 0 28 0
2014 GRIM PAUL A 0 0 0
2015 HOCKING HILLS ENERGY AND WELL 0 162 365
2016 HOCKING HILLS ENERGY AND WELL 0 92 365
2017 HOCKING HILLS ENERGY AND WELL 0 116 365

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 GRIM PAUL A Brine 0 365
1985 GRIM PAUL A Brine 825 365
1986 GRIM PAUL A Brine 802 365
1987 GRIM PAUL A Brine 460 365
1988 GRIM PAUL A Brine 210 365
1989 GRIM PAUL A Brine 145 365
1990 GRIM PAUL A Brine 280 365
1991 GRIM PAUL A Brine 210 365
1992 GRIM PAUL A Brine 280 365
1993 GRIM PAUL A Brine 180 365
1994 GRIM PAUL A Brine 100 365
1995 GRIM PAUL A Brine 300 365
1996 GRIM PAUL A Brine 140 365
1997 GRIM PAUL A Brine 0 365
1998 GRIM PAUL A Brine 0 365
1999 GRIM PAUL A Brine 0 365
2000 GRIM PAUL A Brine 160 365
2001 GRIM PAUL A Brine 80 365
2002 GRIM PAUL A Brine 0 365
2003 GRIM PAUL A Brine 0 365
2004 GRIM PAUL A Brine 0 365
2005 GRIM PAUL A Brine 0 365
2008 GRIM PAUL A Brine 40
2014 GRIM PAUL A Brine 0 0
2015 HOCKING HILLS ENERGY AND WELL Brine 1050 365
2016 HOCKING HILLS ENERGY AND WELL Brine 130 365
2017 HOCKING HILLS ENERGY AND WELL Brine 130 365

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0445372237 2004-12-08 Production Wells No Violations In-Compliance
0459042454 2008-05-06 Production Wells No Violations A follow-up inspection revealed compliance.
0470178679 2005-09-28 Production Wells Violations Noted An inspection of the well revealed well is idle according to landowner for over 1 yr., need full and legible ID at well.
0475565955 2008-02-28 Production Wells Violations Noted A follow-up inspection revealed non-compliance. C&P has not been cleaned up and identification was not observed. Gas was also being released from the well. The well head and stuffing box rubbers need to be replaced.
0510187214 2008-01-04 Production Wells No Violations A follow-up inspection revealed non-compliance.
0544098196 2004-07-08 Production Wells No Violations Follow-up on NOV, Non-Complaince, no action to comply with NOV.
0628214615 2004-02-25 Production Wells Violations Noted An inspection of the well and tank battery revealed no ID at the well or tank battery, brine tank leaking around fitting on bottom of tank, oily soil in and outside dike of tank battery, dike does not meet SPCC requirements.
0732942726 2008-04-29 Production Wells No Violations A follow-up inspection revealed non-compliance.
1009864175 2008-01-08 Production Wells No Violations A follow-up inspection revealed non-compliance.
1060231534 2004-03-30 Production Wells No Violations Follow-up on NOV, Non-Compliance.
1077977690 2008-04-10 Production Wells No Violations A follow-up inspection revealed non-compliance.
1093361390 2004-08-24 Production Wells No Violations Follow-up on NOV, Non-Compliance, no action to comply.
1093459746 2004-08-24 Production Wells No Violations Follow-up on NOV, Non-Compliance, no action to comply.
1134689716 2005-12-13 Production Wells No Violations Follow-up on NOV, Non-Compliance, well still idle, no proof of production sales, no ID on well or tanks.
1147690557 2006-05-09 Production Wells No Violations Follow-up on NOV, Non-Compliance, no action to plug or place well into production.
1150965749 2008-03-10 Production Wells No Violations A follow-up inspection revealed non-compliance. No action has been taken to provide ID or remove contamination and pollution.
1153766004 2006-07-20 Production Wells No Violations Follow up on NOV, and CO, In-Complaince.
1153770973 2006-07-20 Production Wells No Violations Follow-up in compliance per Dan Goins.
1251303960 2009-07-23 Production Wells Violations Noted An inspection revealed that contamination and pollution near the well. The source appears to be from a line break from 2 steel pipe location. An old steel line observed cut. Approximately 5 from well, a new line consisting of 1 black plastic placed inside steel was found routed to the 100 bbl tank. Alongside the pumping unit location and below line location, a bare area with signs of sodicity and standing fluid exhibited 9 units after a High Range Quantab test. The area measured 20 x 10. An oil sheen next to the line measured 5 x 1. Next to 100 bbl steel tank, a Norwesco tank (polyeurothane type) contained a leak from a bottom fitting. Old and fresh oil to include Cl-, in fluid, was observed. Identification was at the 100 bbl tank was not legible and found incomplete, as no permit number, county and well number were observed. The well was pumping at time of the inspection. Made attempt to visit with Mr. Paul Grim at his shop. He was not available therefore, informed his employee to and remove all contaminated material and correct identification.
1316861949 2018-03-07 Production Wells No Violations My inspection revealed the well consists of a pumping unit and 1-100 barrel tank. The well is capable of operation and shows signs of being operated recently. The well has reported production in 2016. The well had a legible identification.
1439852676 2005-09-28 Production Wells Violations Noted FOLLOW UP TO NOV # 470178679 An inspection of the well revealed well is idle according to landowner for over 1 yr., need full and legible ID at well.
1905262003 2008-02-15 Production Wells No Violations A follow-up inspection revealed non-compliance.
2033740787 2007-12-11 Production Wells Violations Noted An inspection revealed contamination and pollution around the well head. New identification will also be required.
2092834817 2009-08-11 Production Wells No Violations A follow-up inspection revealed compliance.
2123858196 2004-07-21 Production Wells No Violations Follow-up on NOV, Non-Complaince.
2131680439 2008-01-16 Production Wells No Violations A follow-up inspection revealed non-compliance.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0470178679 US-OH-125093 2005-10-03 Failure to legibly identify well
0470178679 US-OH-125094 2005-10-03 Well shall be plugged
0470178679 US-OH-125095 2005-10-03 Urban - failure to meet tank battery setbacks from mandatory pooled property
0475565955 US-OH-125171 2008-03-17 Equipment pressure rated below operating pressure
0628214615 US-OH-127115 2004-02-26 Failure to legibly identify well
0628214615 US-OH-127116 2004-02-26 Equipment pressure rated below operating pressure
0628214615 US-OH-127117 2004-02-26 No SPCC dike/or failure to keep dike free of water or oil
1251303960 US-OH-106728 2009-08-26 Inadequate pipeline strength
1251303960 US-OH-106729 2009-08-26 Well operation causing pollution and contamination
1251303960 US-OH-106730 2009-08-26 Failure to legibly identify well
1251303960 US-OH-106731 2009-08-26 Equipment pressure rated below operating pressure
1439852676 US-OH-112805 2005-10-03 Failure to legibly identify well
1439852676 US-OH-112806 2005-10-03 Well shall be plugged
1439852676 US-OH-112807 2005-10-03 Urban - failure to meet tank battery setbacks from mandatory pooled property
2033740787 US-OH-120680 2007-12-13 Well operation causing pollution and contamination
2033740787 US-OH-120681 2007-12-13 Failure to legibly identify well

For data sources see[8]