X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-099-23069

Well Details

Well ID: 34-099-23069
Loading map...
Country: United States
State: Ohio
County: Mahoning
Municipality: Boardman Township
Operator Name: EVERFLOW EASTERN PTNS L P
Well Pad ID:
Farm/Lease Name: UNTCH UNIT
License Status: Producing
License Date: 2008-01-07
Spud Date: 2008-04-30
Spud Drilling Contractor: UNION DRLG
Final Drill Date: 2008-05-10
Well Total Depth: 5997 ft
Configuration: Directional
Latitude: 41.035329690
Longitude: -80.65421924

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2008-01-07 Proposed Formations:CLINTON, Issued Date:1/7/2008, Expired Date:1/6/2009 6:00:00 AM, Drilling unit acres:42.55, Proposed Well Type:OG, Proposed Well Class:POOL
Reached Total Depth 2008-05-10
Completion Report Received 2008-06-12
Construction Permit Expires 2009-01-06
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-09-16 5754 5814 126

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2857 Bbl 98000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2008 EVERFLOW EASTERN PTNS L P 7219 0 365
2009 EVERFLOW EASTERN PTNS L P 20032 113 365
2010 EVERFLOW EASTERN PTNS L P 11182 14 365
2011 EVERFLOW EASTERN PTNS L P 12614 31 365
2012 EVERFLOW EASTERN PTNS L P 8767 18 276
2013 EVERFLOW EASTERN PTNS L P 8695 26 365
2014 EVERFLOW EASTERN PTNS L P 6305 13 290
2015 EVERFLOW EASTERN PTNS L P 275 0 365
2016 EVERFLOW EASTERN PTNS L P 32 0 365
2017 EVERFLOW EASTERN PTNS L P 3135 0 365
2018 EVERFLOW EASTERN PTNS L P 3928 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2008 EVERFLOW EASTERN PTNS L P Brine 0 365
2009 EVERFLOW EASTERN PTNS L P Brine 40 365
2010 EVERFLOW EASTERN PTNS L P Brine 38 365
2011 EVERFLOW EASTERN PTNS L P Brine 42 365
2012 EVERFLOW EASTERN PTNS L P Brine 26 276
2013 EVERFLOW EASTERN PTNS L P Brine 56 365
2014 EVERFLOW EASTERN PTNS L P Brine 11 290
2015 EVERFLOW EASTERN PTNS L P Brine 0 365
2016 EVERFLOW EASTERN PTNS L P Brine 0 365
2017 EVERFLOW EASTERN PTNS L P Brine 0 365
2018 EVERFLOW EASTERN PTNS L P Brine 12 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0022062187 2008-06-09 Preliminary Restoration No Violations I performed a preliminary restoration status check. The drilling pits were solidified and closed. The drilling equipment was gone the debris was hauled away. The top soil is still in piles on location. This well does not pass preliminary restoration.
0114335812 2008-05-12 Drill / Deepen / Reopen No Violations I received a message on 5/9/08 from Dave Claus about a complaint from Mr. Zeyer about his garage bricks that have cracked. I have tried to call him numerous times and left messages on his home and work phones. I called Everflow Eastern, Mr. Les Dundics(Landman) about the crack. He tried to call Mr. Zeyer and ended up leaving a message. I called today and left him messages on his home and work phones. The rig is 600 south of the condo is question. There are other condos within 500 of the rig. I will keep the complaint open until I talk to Mr. Zeyer about the crack outside his garage. Case continues.
0159898925 2008-05-01 Drill / Deepen / Reopen No Violations I performed a rig inspection. The pit liners were in good shape. The ID sign was posted and the location was in good shape. There were no violations at this time.
0290057919 2008-05-13 Preliminary Restoration No Violations I received a call from Mr. Zeyer and was told that he had checked all the other condos in the area. All but 4 had the same crack on the garage door area. He assumed it was a poor construction problem and not the drilling rig. I told him that the rig was 600 from his condo and that it was almost impossible for the rig to cause the crack. Mr. Zeyer called me back and stated that all but 4 condos had the same thing above the garages. This case is resolved.
0405254422 2008-05-01 Drill / Deepen / Reopen No Violations I witnessed the cementing of the 8 5/8 casing. There were no violations at this time.
0746281715 2008-09-11 Preliminary Restoration No Violations I performed a preliminary restoration status check. I GPSd both the wellhead and the tank battery. The drilling rig and the debris are gone. The pits are closed. The location is a parking lot for the Untch equipment. There is a mound on the east side for a sound bearer. The mound has vegetation growth with trees. The ID signs were posted. This well has PASSED PRELIMINARY RESTORATION.
1210071373 2008-05-05 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling pit liners were in good shape as well as the location. The drilling depth was 3641. I found no violations at this time.
1210619439 2008-05-12 Preliminary Restoration No Violations I performed a preliminary restoration status check. The drilling pit liners were in good shape. The fluid level in the pits were down 2 foot. I found no violations at this time. This well does not pass preliminary restoration.
1327683451 2012-01-27 UrbanProduction Wells No Violations I conducted a status check on this site and found that the well is equipped with a plunger lift system and connects to a tank battery that consists of one 100 barrel stock tank and three separators. There was no brine storage tank. The thief hatch was closed and there was a bull plug installed in the draw valve. The dike was free of vegetation and debris. The tank battery is shared with permits 2790, 2791 and 2111. Proper identification was posted. I found no leaks or spills at the well head or the tank battery. I took new GPS coordinates of the well head and tank battery. No violations at this time.
1580608255 2008-05-07 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling pit liners were in good shape. The location was in good shape. The drilling depth was 4281. There were no violations at this time.
1611515418 2008-05-08 Drill / Deepen / Reopen No Violations I performed a rig inspection. The drilling pits and the location were in good shape. The drilling depth was 4283. There were no violations at this time.
1672364967 2008-07-23 Preliminary Restoration No Violations I performed a preliminary restoration status check. I GPSd both the tank battery and the wellhead. The drilling rig and the debris was gone. The pits are closed. The location will be the back part of the parking lot. A mound is up on the east side. I talked to Mr. Untch which stated the trees will be planted on top so that the neighbors would have a buffer between the well and there property. The trees have not been planted yet. This well does not pass preliminary restoration.

For data sources see[9]

References