X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-127-26096

Well Details

Well ID: 34-127-26096
Loading map...
Country: United States
State: Ohio
County: Perry
Municipality: Harrison Township
Operator Name: SWINGLE DRILLING INC
Well Pad ID:
Farm/Lease Name: MAIER UNIT
License Status: Producing
License Date: 2006-02-24
Spud Date: 2006-03-06
Spud Drilling Contractor: AZTEC DRLG
Final Drill Date: 1983-11-22
Well Total Depth: 3710 ft
Configuration: Vertical
Latitude: 39.750408933
Longitude: -82.08520410

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1983-11-01 50 SWINGLE DRILLING INC GeoDate 11/1/83
Oil and Gas 1983-11-01 Issued Date 11/1/83 Expired Date 4/29/84 Acres 0020000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 03710 Proposed Drill Depth 03710
Original Spud 1983-11-16 OTD: 3710' IN CLINTON
Completed 1983-11-22 OTD: 3710' IN CLINTON
Reached Total Depth 1983-11-22 OTD: 3710' IN CLINTON
APP 2006-02-24 Proposed Formations:BEREA, Issued Date:2/24/2006, Expired Date:2/24/2007 6:00:00 AM, Drilling unit acres:20, Proposed Well Type:OG, Proposed Well Class:ESPW
Plugged Back 2006-03-07 OTD: 3710' IN CLINTON
Construction Permit Expires 2007-02-24 OTD: 3710' IN CLINTON
Completion Report Received 2007-11-15 OTD: 3710' IN CLINTON
Last Compliance Report 2017-03-17 OTD: 3710' IN CLINTON
Record Last Modified 2017-03-17 OTD: 3710' IN CLINTON

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2008-02-14 936 946 20
2008-02-14 3560 3570 24

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 313 Mscf 0 SCF N2
FOAM 0 0 30000 FRAC: GELD WATER, SAND, N2
H2O 15 23300 Gal 5000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 SWINGLE DRILLING INC 1538 1254 0
1985 SWINGLE DRILLING INC 1257 883 0
1986 SWINGLE DRILLING INC 1822 544 365
1993 SWINGLE DRILLING INC 0 454 365
1995 SWINGLE DRILLING INC 668 154 365
1999 BUTCHER ENERGY CORP 1027 0 365
2000 SWINGLE DRILLING INC 398 75 365
2001 SWINGLE DRILLING INC 246 75 365
2002 SWINGLE DRILLING INC 150 0 365
2003 SWINGLE DRILLING INC 164 76 365
2004 SWINGLE DRILLING INC 95 0 365
2005 SWINGLE DRILLING INC 121 77 365
2006 SWINGLE DRILLING INC 0 55 365
2007 SWINGLE DRILLING INC 26 0 365
2008 SWINGLE DRILLING INC 1017 0 365
2009 SWINGLE DRILLING INC 406 0 365
2010 SWINGLE DRILLING INC 188 0 365
2011 SWINGLE DRILLING INC 0 0 365
2012 SWINGLE DRILLING INC 587 0 0
2013 SWINGLE DRILLING INC 0 0 0
2014 SWINGLE DRILLING INC 20 0 365
2015 SWINGLE DRILLING INC 83 0 365
2016 SWINGLE DRILLING INC 307 0 365
2017 SWINGLE DRILLING INC 218 0 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 SWINGLE DRILLING INC Brine 100 0
1985 SWINGLE DRILLING INC Brine 80 0
1986 SWINGLE DRILLING INC Brine 72 365
1993 SWINGLE DRILLING INC Brine 0 365
1995 SWINGLE DRILLING INC Brine 0 365
1999 BUTCHER ENERGY CORP Brine 0 365
2000 SWINGLE DRILLING INC Brine 0 365
2001 SWINGLE DRILLING INC Brine 0 365
2002 SWINGLE DRILLING INC Brine 0 365
2003 SWINGLE DRILLING INC Brine 0 365
2004 SWINGLE DRILLING INC Brine 0 365
2005 SWINGLE DRILLING INC Brine 0 365
2006 SWINGLE DRILLING INC Brine 0 365
2007 SWINGLE DRILLING INC Brine 0 365
2008 SWINGLE DRILLING INC Brine 0 365
2009 SWINGLE DRILLING INC Brine 0 365
2010 SWINGLE DRILLING INC Brine 0 365
2011 SWINGLE DRILLING INC Brine 0 365
2012 SWINGLE DRILLING INC Brine 0 0
2013 SWINGLE DRILLING INC Brine 0 0
2014 SWINGLE DRILLING INC Brine 0 365
2015 SWINGLE DRILLING INC Brine 0 365
2016 SWINGLE DRILLING INC Brine 0 365
2017 SWINGLE DRILLING INC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000PL6868 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0046350134 2009-02-27 Annular Disposal No Violations No violations.
0375966878 2008-06-02 Annular Disposal No Violations No violations.
0631262024 2012-03-27 Annular Disposal No Violations Follow-up on Compliance Notice, In-Compliance.
0814267424 2016-04-07 Production Wells No Violations I was at this well to do a field inspection on this well. The well appears to be capable of production. The well has a pumping unit on it with rods and 1.5 tubing down hole. The production valves coming off the well to the tank pad are open at this time. The identification for this well is located at the production tank. There are no violations to report.
0889241912 2018-10-03 Production Wells No Violations I was at this well to do a field inspection on this well. The well appears to be capable of production. The well has a pumping unit on it with rods and 1.5 diameter tubing down hole. The production valves coming off the well to the tank pad are open at this time. The identification for this well is located at the production tank. There are no violations to report.
1142281764 2006-03-08 Plug / Plug Back No Violations Plug back
1249752795 2011-11-07 Annular Disposal Violations Noted An inspection of the well revealed fittings on production tank leaking, repair or replace fittings. Clean up any and all oily material around production tanks and dispose of in a proper manner. No dike around tanks, build a dike around tanks to meet SPCC requirements.
1330205053 2017-02-02 Temporary Abandoned Annular Disposal No Violations I was on location today to check the annular disposal for Columbus. The annular disposal is not hooked up at this time.
1920267290 2006-01-17 Annular Disposal No Violations Checked AD for Columbus, AD not being used.
2068437148 2013-09-09 Production Wells No Violations The well appears to be in production. It has a pumping unit on it with rods 1.5 tubing. The valves at the wellhead are open to the production tank. The identification for the well is on the tank. No violations at this time.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1249752795 US-OH-106432 2011-11-16 Equipment pressure rated below operating pressure
1249752795 US-OH-106433 2011-11-16 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References