Well ID: 34-055-21524 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.397155867,"lon":-81.14299493,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Geauga | |
Municipality: Troy Township | |
Operator Name: M & R INVESTMENTS OHIO LLC | |
Well Pad ID: | |
Farm/Lease Name: O'REILLY RUSSELL | |
License Status: Producing | |
License Date: 1988-01-19 | |
Spud Date: 1988-04-21 | |
Spud Drilling Contractor: PEP DRLG | |
Final Drill Date: 1988-04-28 | |
Well Total Depth: 6773 ft | |
Configuration: Vertical | |
Latitude: 41.397155867 | |
Longitude: -81.14299493 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1988-01-19 | 213 LOMAK OPERATING CO GeoDate 1/19/88 |
Oil and Gas | 1988-01-19 | Issued Date 12/31/87 Expired Date 12/30/88 Acres 0040000 Tool Type RTA Proposed Formation CL/ROSE RUN Proposed Depth 06773 Proposed Drill Depth 06773 |
Original Spud | 1988-04-21 | PB FOUND IN FORMATIONS. |
Completed | 1988-04-28 | PB FOUND IN FORMATIONS. |
Plugged Back | 1988-04-28 | PB FOUND IN FORMATIONS. |
Reached Total Depth | 1988-04-28 | PB FOUND IN FORMATIONS. |
Completion Report Received | 1988-09-08 | PB FOUND IN FORMATIONS. |
Construction Permit Expires | 1988-12-30 | PB FOUND IN FORMATIONS. |
Change of Owner | 2000-06-27 | Operator changed from 213, RANGE OPERATING COMPANY to 6674, GREAT LAKES ENERGY PTNSHP LLC |
Change of Owner | 2010-04-08 | Operator changed from 6674, RANGE RESOURCES-APPALACHIA LLC to 7578, ENERVEST OPERATING LLC |
Change of Owner | 2017-08-24 | Operator changed from 7578, ENERVEST OPERATING LLC to 8685, M & R INVESTMENTS OHIO LLC |
Record Last Modified | 2017-08-24 | PB FOUND IN FORMATIONS. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
1997-06-29 | 3929 | 4054 | 0 |
2006-09-11 | 3951 | 4014 | 33 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1800 Bbl | 40000 | FRAC: WATER, SAND |
For data sources see[4]
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
0633844502 | 2013-09-09 | Production Wells | No Violations | My inspection found the well to be equipped with a plunger lift unit. The well and tank battery are in good repair. The tank battery is surrounded by a chain link fence. The tank battery consists of a 210 BBL production tank, a 50 BBL poly brine tank, and two mechanical separators. The proper identification is located on the tank battery. The lease road is in stable condition. The tank battery and lease road are being shared by permit number 2-1530. |
0913008252 | 2011-02-18 | Production Wells | No Violations | One 210Bbls tank , one 1500 gal poly tank and two mechanical separators in the battery. Permit 34-055-21530-00-00 is also produced into the battery. Lease road is stable. |
1540439376 | 2018-06-12 | Production Wells | No Violations | At the time of this inspection, the well was equipped with a plunger lift assembly. The gate valve on the tubing and the 2 inch flow line valve was open. Production for this well was current. The tank battery was equipped with one 210 BBL tank, one 50 BBL tank and two mechanical separators. Valves on the separators were open and the charts on the sales lines showed production. The tank battery was diked and fenced with legible signage. The tank battery was shared with well 2-1530. The lease access was stable. No violations observed. |
1852305970 | 2012-09-27 | Production Wells | No Violations | The unit consists of a 2-tank battery (TB) with 2 mechanical separators located in a 6-foot chainlink fence. The unit shares the TB with the #1530 unit. The spacing is in accordance with the rule. I could not locate the wellhead. I did not observe any signs of leaking product or gas vapors. The gate needs a lock and dike weeds need cut. The tank battery dike is adequate. I contacted Tom Havraenk at Enervest regarding maintenance. He indicated that the maintenance would be done in the next month. |
For data sources see[9]